• Title/Summary/Keyword: Force measurement

Search Result 1,614, Processing Time 0.032 seconds

Finite Element Analysis and Static Load Test of a Wheelset of Gwangju EMU for Measuring Wheel/Rail Force (차륜/궤도 작용력 측정을 위한 광주전동차 윤축의 구조해석 및 정하중 시험)

  • Jeon Eung-Sik;Ham Young-Sam;Chung Woo-Jin
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.762-767
    • /
    • 2003
  • The railroad is a means of large transportation which has many talents such as a safety and a regularity. That is a results from various confidential performance tests and evalutions of the system. The railroad system consist of various subsystems - vehicle, power spply, signal communications, track structures, operations, etc. Among them as an item of safety evaluation there is a measurement of wheel/rail force, so called a measurement of derailment coefficient. This is a very important item because a derailment of a train will bring about a big accident. Especially it is more important in high speed rail of which operation speed is over two times as fast as existing rail. In this paper, it is introduced to preprocess the wheelset for measuring wheel/rail force of Gwangiu EMU, such as to treat a measuring wheelset its finite element analysis, adhesion of strain gauges and static load test.

  • PDF

Analysis the static thrust force and dynamic thrust force in HB-type Linear Pulse Motor (하이브리드형 선형 펄스모터의 정추력 및 동추력 분석)

  • Kim, Dong-Hee;Ahn, Jae-Young;Kim, Kwang-Heon
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.214-216
    • /
    • 2007
  • The linear motor is available for linear transition motion, because of its advantages, the motor design and its application have gradually increased, but the quantitative measurement system of thrust force has not been generalized. Need analysis of correct thrust for control performance improvement of HB-LPM(HB-type Linear Pulse Motor). It is difficult to analyze HB-LPM's thrust. In this paper, HB-LPM's thrust is expressed to mathematical expression. And it is proved validity of this numerical formula by thrust measurement system. Two phase driver is composed. It is verified validity of numerical formula that measure waveform of electric current and voltage that is supplied in each phase.

  • PDF

A Cantilever Type Contact Force Sensor Array for Blood Pressure Measurement (혈압 측정을 위한 외팔보형 접촉힘 센서 어레이)

  • Lee, Byeung-Leul;Jung, Jin-Woo;Chun, Kuk-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.121-126
    • /
    • 2012
  • Piezoresistive type contact force sensor array is fabricated by (111) Silicon bulk micromachining for continuous blood pressure monitoring. Length and width of the unit sensor structure is $200{\mu}m$ and $190{\mu}m$, respectively. The gap between sensing elements is only $10{\mu}m$. To achieve wafer level packaging, the sensor structure is capped by PDMS soft cap using wafer molding and bonding process with $10{\mu}m$ alignment precision. The resistance change over contact force was measured to verify the feasibility of the proposed sensor scheme. The maximum measurement range and resolution is 900 mm Hg and 0.57 mm Hg, respectively.

Discussion of Problems During the Application of the On-line Particle Counter In Water Treatment Process (정수처리 공정에서 연속식 입자계수기의 적용성 검토에 관한 연구)

  • Moon, Seong-Yong;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.214-220
    • /
    • 2005
  • Errors may occur due to analysis methods and water quality during the application of the on-line particle counter In water treatment process. Errors caused by analysis methods include particle destruction by shear force due to inflow speed and tube friction, as well as interruption by screening, bubbles and contaminants. Since errors happen frequently because of these factors, it is necessary to examine and evaluate such errors during the application of a particle counter. Errors can be large due to screening and bubbles. Measurement values are effective for water analysis after filtration process. However, because of screening, only measurement values for particles above $7{\mu}m$ are valid for water with a turbidity between 3-10NTU. As particle numbers around $10{\mu}m$ increase a lot after ozone treatment, sufficient pretreatment process is necessary. Physical conditions should keep stable for inflow to decrease errors caused by shear force.

A New Method for Lateral Force Calibration in Atomic Force Microscope (원자현미경(AFM)에서 마찰력 측정을 위한 새로운 보정 기술 연구)

  • Yoon Eui-Sung;Kim Hong Joon;Wang Fei;Kong Hosung
    • Tribology and Lubricants
    • /
    • v.21 no.5
    • /
    • pp.221-226
    • /
    • 2005
  • A new calibration method for exact measurement of friction force in atomic force microscope (AFM) is presented. A new conversion factor involves a contact factor affected by tip, cantilever and contact stiffness. Especially the effect of contact stiffness on the conversion factor between lateral force and lateral signal is considered. Conventional conversion factor and a new modified conversion factor were experimentally compared. Results showed that a new calibration method could minimize the effect of normal load on friction force and improve the conventional method. A new method could be applied to the specimens with different physical properties.

Contact Force Estimation for a Polishing Brush (연마 브러시 접촉력 산출)

  • Lee, Byoung-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.1
    • /
    • pp.58-63
    • /
    • 2010
  • A new contact force estimation technique is proposed. Keeping the contact force at a certain level between finishing tool and the object is essential since the quality of the finished surface is very sensitive to the contact force during the finishing process. However, the contact force measurement cannot be obtained by simply installing load cells under machine table or in the middle of tool linkage. The reason is that the weight of the machine table and the tool linkage are much heavier than the force to be measured. To that end, a method for estimating disturbance is proposed for a system that is similar to the mechanism of the finishing machine, and the same method is applied to estimate the contact force of the brush-type finishing machine. To verify the effectiveness of the proposed method, a small scale test set-up has been built and the method has been tested.

A Development of Combined-Type Tool Dynamometer for Ultraprecision Lathe with Piezo-Film Accelerometer (복합 압전필름형 가속도계를 이용한 초정밀 선반 공구동력계의 개발에 관한 연구)

  • Kim, J.D.;Kim, D.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.2
    • /
    • pp.87-96
    • /
    • 1995
  • The cutting force is the most important variable to understand the mechanics of ultra-precision machining. Most dynamometers, however, monitor the static cutting force only. But it is necessary to measure the dynamic cutting force to clarify the machinability of the material, the formation of the chip, chatter and the wear of the tool. In this research, measurement of the dynamic cutting force in order to clarify the machin-ability of the material, the formation of the chip, chatter and the wear of the tool has been conducted. A combined-type dynamometer which could measure the static cutting force and the dynamic cutting force by use of strain gauges and a piezo-film accelerometer has been developed. An analysis of the dynamometer also has been carried out.

  • PDF

A Study on the Development of the CMM Probe using Force-Sensor (힘 센서를 이용한 CMM용 프로브 개발을 위한 연구)

  • 송광석;권기환;박재준;조남규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.411-415
    • /
    • 2002
  • In this paper, a mechanical probe for CMM (Coordinate Measuring Machine) with a three-axis force-sensing unit is proposed, which is capable of measuring an actual contact position without the lobbing effect and the pre-travel error. The force-sensing unit detects the external force, which is act on the stylus of CMM during the measuring process. Thus, the contact point of the stylus of CMM can be estimated ken the direction of measured force components. Based on the structural analysis of the proposed CMM probe, the transformation matrix is derived and calibrated so that it shows linear relationships between the estimated force components from the output voltages and the real input forces. And, the relationships are verified through the computer simulation. The results show that the proposed mechanical probe is very useful fur detecting the contacting force components on measuring process of CMM.

  • PDF

Measurement of Gastric Contractility of Awake Rats by Bowel Sounds Recorded through an Electronic Stethoscope in a Sound Insulation Box (차음상자와 전자청진기로 기록된 장음에 의해서 깨어 있는 흰쥐의 위수축력 측정)

  • Yoon, Sang-Hyub
    • The Journal of Internal Korean Medicine
    • /
    • v.35 no.4
    • /
    • pp.439-447
    • /
    • 2014
  • Objectives: The aim of this study was to investigate whether 1) variation of bowel sounds recorded stably through an electronic stethoscope in a sound insulation box can be related with that of gastric contraction and 2) if they are thus useful tool in the measurement of the gastric contractility in awake rats or not. Methods: Electrical potentials of both electronic stethoscope of bowel sound and force transducer were recorded simultaneously and continuously in the sound insulation box for the starting 30 min of basal state, and then 30 min of 0.2 ml normal saline administration, finally 30 min of 0.2 ml mosapride citrate solution (100 mg/Kg) in rats. Each motility index of normal saline or mosapride citrate treatment was presented with ratio against the basal state by using integrated electrical potentials. Results: A pattern of significance of gastric contractility between bowel sound and force transducer was showed analogously. Conclusions: The amplitude of bowel sounds recorded by the electronic stethoscope related with the intensity of gastric contractions. This confirms that a sound insulation box and electronic stethoscope are useful tools in the measurement of the gastric contractility of awake rats.

Power spectra of wind forces on a high-rise building with section varying along height

  • Huang, D.M.;Zhu, L.D.;Chen, W.
    • Wind and Structures
    • /
    • v.18 no.3
    • /
    • pp.295-320
    • /
    • 2014
  • The characteristics of amplitudes and power spectra of X axial, Y axial, and RZ axial (i.e., body axis) wind forces on a 492 m high-rise building with a section varying along height in typical wind directions are studied via a rigid model wind tunnel test of pressure measurement. Then the corresponding mathematical expressions of power spectra of X axial (across-wind), Y axial (along-wind) and torsional wind forces in $315^{\circ}$ wind directions are proposed. The investigation shows that the mathematical expressions of wind force spectra of the main structure in across-wind and torsional directions can be constructed by the superimposition of an modified wind spectrum function and a peak function caused by turbulent flow and vortex shedding, respectively. While that in along-wind direction can only be constructed by the former and is similar to wind spectrum. Moreover, the fitted parameters of the wind load spectra of each measurement level of altitude are summarized, and the unified parametric results are obtained. The comparisons of the first three order generalized force spectra show that the proposed mathematical expressions accord with the experimental results well.