• 제목/요약/키워드: Foot Plantar Pressure

검색결과 170건 처리시간 0.024초

성인 여성의 발 특성에 따른 인솔 적합성 연구 (The Research of the Insole Suitability in Accordance with Foot Characteristics of Women)

  • 최순복;이원자
    • 한국의류학회지
    • /
    • 제29권6호
    • /
    • pp.783-792
    • /
    • 2005
  • The purpose of this research is to develop appropriate Insole according to foot characteristics of female adults. This research concentrates on proving the effectiveness of Insole on resolving foot discomforts by analyzing the differences between the fitting and foot pressure before and after wearing Insole. Among 216 female testers of previous research, six testers wear selected and placed into six different groups classified according to foot discomforts and foot characteristics. After wearing Insole, the results indicates that the entire groups represented the improvement of fitting and the mitigation of foot discomfort. The results of foot pressure experiment shows that the maximum pressure of foot spreads out evenly after wearing Insole, which indicates the effectiveness of Insole. This efficacy works particularly well for foot testers of second and sixth group. The results indicate that group 6, which consist of the flat-footed and the old, have more noticeable effects derived from Insole, whereas group 3 and 5 do not, due to its constitution of people with fairly normal feet. Furthermore, it was evident that maximum pressure played a major role in proving the beneficial effects of Insole, one of which is to scatter the maximum pressure of heel away and lessen the foot pressure of plantar.

키높이 인솔두께에 따른 족부의 생체역학적 특성변화에 대한 연구 (A Study on Changes in Biomechanical Characteristics of the Foot with Respect to Wedge-type Insole Thickness)

  • 박태현;정태곤;한동욱;이성재
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권2호
    • /
    • pp.80-90
    • /
    • 2013
  • Recently, functional insoles of wedge-type it is for the young to raise their height inserted between insole and heel cause foot pain and disease. Additionally, these have a problem with stability and excessively load-bearing during gait like high-heel shoes. In this study, we compared the changes in biomechanical characteristics of foot with different insole thickness then we will utilize for the development of the insole with the purpose of relieving the pain and disease. Subjects(male, n = 6) measured COP(center of pressure) and PCP(peak contact pressure) on the treadmill(140cm/s) using F-scan system and different insole thickness(0~50 mm) between sole and plantar surface during gait. Also, we computed changes of stresses at the foot using finite element model with various insole thickness during toe-off phase. COP moved anterior and medial direction and, PCP was increased at medial forefoot surface, $1^{st}$ and $2^{nd}$ metatarsophalangeal, ($9%{\uparrow}$) with thicker insoles and it was show sensitive increment as the insole thickness was increased from 40 mm to 50 mm. Change of the stress at the soft-tissue of plantar surface, $1^{st}$ metatarsal head represents rapid growth($36%{\uparrow}$). Also, lateral moments were increased over the 100% near the $1^{st}$ metatarsal as the insole thickness was increased from 0 mm to 30 mm. And it is show sensitive increment as the insole thickness changed 10 mm to 20 mm. As a result, it was expected that use of excessively thick insoles might cause unwanted foot pain at the forefoot region. Therefore, insole thickness under 30 mm was selected.

도구를 이용한 연부조직가동술과 정적 스트레칭이 족저압과 발목관절 가동범위에 미치는 영향 (Effect of the Instrument Assisted Soft Tissue Mobilization and Static Stretching on the Range of Motion and Plantar Foot Pressure of an Ankle Joint)

  • 이재홍;이진환;민동기;김광수;김종우
    • 대한정형도수물리치료학회지
    • /
    • 제23권2호
    • /
    • pp.27-32
    • /
    • 2017
  • Background: The purpose of this study was to compare the effects of IASTM and static stretching techniques on ankle joint range of motion (ROM), static foot pressure. Methods: Twenty four subjects with gastrocnemius shortness participated in this study. The subjects were assigned randomly to one of two groups: The soft tissue mobilization technique (IASTM) group received intervention using a IASTM instrument for two minutes, and the stactic stretching group performed self stretching for 30 seconds, four times. The ROM of the ankle joint was measured by active ankle dorsi-flexion test, and a TPScan was utilized to collect the plantar foot pressure. This experiment was performed by two physical therapists. The significant level was set at ${\alpha}=.05$. Results: The results were as follows: 1) The ROM of the ankle joint and was significantly increased in both groups. 2) Plantar foot pressure was no significant in both groups. 3) There were no significant differences between the IASTM group and static stretching group for any variable. Conclusions: The results of this study suggest that static stretching is an effective and easy technique for restoring proper muscle length in subjects with gastrocnemius shortness. We recommend that static stretching technique be used for treat gastrocnemius shortness in clinical setting and home program.

  • PDF

Toe Spreader가 경직성 뇌성마비 아동의 동적 족압 특성에 미치는 영향 (The Effect of Toe Spreader on Characteristics of Dynamic Foot Pressure in Children With Spastic Cerebral Palsy)

  • 신화경;태기식
    • The Journal of Korean Physical Therapy
    • /
    • 제22권1호
    • /
    • pp.47-51
    • /
    • 2010
  • Purpose: The purpose of this study was to determine whether there are any differences, with and without a toe spreader (TS), in dynamic foot pressure distribution in children with spastic diplegic cerebral palsy. Methods: Dynamic foot pressure recording using the RSscan system were obtained during walking in 12 participants (male=7, female=5) with and without TS. Mean force was measured for four different plantar regions; great toe, forefoot, midfoot, hindfoot. Displacement of center of pressure (COP), velocity of COP displacement and stance time were also measured during gait. Results: TS walking exhibited statistically significant decrease of mean force under great toe and forefoot (p<0.05), compared with a barefoot walking. Also, TS walking exhibited statistically significant increase of antero-posterior displacement of COP (p>0.05). Conclusion: These findings indicate the potential clinical utility of toe spreader to correct dynamic foot pressure during stance phase in children with spastic diplegic cerebral palsy.

협응이동훈련이 척추 측만증 고객의 족저압과 균형에 미치는 효과 -단일사례연구- (Effect of Coordinative Locomotor Training on Balance and Plantar Foot Pressure in Scoliosis Patients -A Single Subject Study-)

  • 김진철;김태윤;이정아
    • PNF and Movement
    • /
    • 제15권3호
    • /
    • pp.227-236
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the effects of coordinative locomotor training (CLT) on the foot pressure and balance of patients with scoliosis. Methods: This was a single-case A-B-A study involving two patients with scoliosis. The study was designed to perform repeated measurements as follows: 5 times at baseline (A), 10 times during intervention (B), and 5 times after intervention (A). The study period was 5 weeks, and the CLT program was divided into warm up, CLT program, and cool down stages, at 50 min per stage. For the primary outcome measure, Gait View AFA-50 was used to determine the foot pressure and balance ability. For the secondary outcome measure, the SRS-22 questionnaire was used to assess the quality of life of the patients with scoliosis. Descriptive statistics and visual analysis using graphs were used to compare the rates of change. Results: The results of this study showed that the foot pressure and balance ability of the two subjects improved during the intervention period and remained improved even during the baseline period. However, their quality of life did not change after the intervention. Conclusion: CLT may have a positive effect on foot pressure and balance ability in patients with scoliosis. Also, this body function improvement may have positive effects on the performance of daily activities which employ the upright position.

휠체어에서 엉덩이 들기 동작 동안 발위치가 척수손상환자의 어깨 근활성도, 최대 족저압, 무릎굽힘 각도, 운동자각도에 미치는 효과 비교 (Comparison of the Effects of Different Foot Positions During Body-lifting in Wheelchair on Shoulder Muscle Activities, Peak Plantar Pressure, Knee Flexion Angle, and Rating Perceived Exertion in Individuals With Spinal Cord Injury)

  • 이왕재;임원빈;윤병구;이범석;이충휘
    • 한국전문물리치료학회지
    • /
    • 제24권2호
    • /
    • pp.1-8
    • /
    • 2017
  • Background: Individuals with spinal cord injury (SCI) rely on their upper limbs for body-lifting activity (BLA). While studies have examined the electromyography (EMG) and kinematics of the shoulder joints during BLA, no studies have considered foot position during BLA. Objects: This study compared the effects of different foot positions during BLA on the shoulder muscle activities, peak plantar pressure, knee flexion angle, and rating perceived exertion in individuals with SCI. Methods: The study enrolled 13 mens with motor-complete paraplegic SCI, ASIA (American Spinal Injury Association) A or B. All subjects performed BLA with the feet positioned on the wheelchair footrest and on the floor independently. Surface EMG was used to collect data from the latissimus dorsi, pectoralis major, serratus anterior, and triceps brachii. The peak plantar pressure was measured using pedar-X and the knee flexion angle with Image J. Borg's rating perceived exertion scale was used to measure the physical activity intensity level. The paired t-test was used to compare the shoulder muscle activities, peak plantar pressure, knee flexion angle, and rating perceived exertion between the two feet positions during BLA. Results: The activity of the latissimus dorsi, pectoralis major, serratus anterior, and triceps brachii and rating perceived exertion decreased significantly and the peak plantar pressure and knee flexion angle increased significantly when performing BLA with the feet positioned on the wheelchair footrest compared with on the floor (p<.05). Conclusion: These findings suggest that individuals with SCI may perform BLA with the feet positioned on the wheelchair footrest for weight-relief lifting to decrease the shoulder muscle activities and the rating perceived exertion and to increase the peak plantar pressure and the knee flexion angle.

안전화 형태와 Insole 착용 유무에 따른 보행동작시 하지부위에 대한 지면반발력과 압력분포 부하 (A study on the ground reaction forces and plantar pressure variables in different safety shoes and applying insole during walking)

  • 김중진;최상복;차상은
    • 한국산업보건학회지
    • /
    • 제17권2호
    • /
    • pp.131-143
    • /
    • 2007
  • The purpose of this study was to compare the ground reaction forces and plantar pressure variables among three different safety shoes (Type 1: ergonomically designed and high quality shoes, 2: curved and cushioned safety hoes, and 3: regular safety shoes) and to find the effect of insole during walking. Ten healthy subjects were recruited for this study. The ground reaction force was measured using a 3 dimensional motion analysis system. Plantar pressures were measured Pedar Mobile foot pressure scan system. The ground reaction force variables were not significantly different among three different shoe types and insole conditions. After insertion insole, plantar pressure distributions were improved. These results suggest that the type 1 safety shoes was superior than other safety shoes in the statistics, and applying insole could be a possible method to prevent fatigue of lower extremity and musculoskeletal disorders. Further studies are needed to find the effect of ergonomically designed safety shoes design and insole on practical value prevention of musculoskeletal disorder, fatigue and satisfaction of workers.

발의 유형과 발목 관절 피로 수준이 외발서기 시 압력중심점과 질량중심점 궤적에 미치는 영향 (Effects of Foot Type and Ankle Joint Fatigue Levels on the Trajectories of COP and COM during a Single-Leg Stance)

  • 신영화;염창홍;손민지
    • 한국운동역학회지
    • /
    • 제23권4호
    • /
    • pp.335-345
    • /
    • 2013
  • The purpose of this study was to investigate the effects of foot type and ankle joint fatigue levels on the trajectories of center of pressure and center of mass during a single-leg stance. The study subjects included 24 healthy women (normal foot group, n=10; pronated foot group, n=14). Ankle joint muscle fatigue was induced by using an isokinetic dynamometer, where the fatigue levels were measured on plantar flexion and dorsiflexion at angular velocities of $30^{\circ}/s$ at 50% and 30% of the peak torque of ankle plantar flexion. Following assessments in the anteroposterior direction according to the level of fatigue, the pronated foot group showed decreased single-leg stance ability at 50% and 30% of the fatigue level. Moreover, the normal foot group showed better single-leg stance ability than the pronated foot group at 30% of the fatigue level. Following assessments in the mediolateral direction, we noted that the single-leg stance ability did not differ significantly according to the levels of fatigue or foot type. In conclusion, ankle plantar flexion at 50% and 30% of the peak torque reduced the ability of the pronated foot group to achieve a single leg stance in the anteroposterior direction. Moreover, the normal foot group showed better single-leg stance ability than the pronated foot group.

정상의 발과 병적인 발에서 발보조기 연구의 비판적 고찰 (A Critical Review of Foot Orthoses in Normal and Diseased Foot)

  • 김승재;김장환;탁계래;배상우;박영기
    • 한국운동역학회지
    • /
    • 제17권3호
    • /
    • pp.81-94
    • /
    • 2007
  • The purpose of this study was to critically review biomechanical studies on foot orthoses (FO) in normal and diseased foot and provide beneficial information obtained from researches until now and future researching focus. The search was performed by Medline and Embase database including studies published in English from January 1980 to April 2007. The searching terms were foot orthoses, foot orthotics, insoles and shoe insert. 57 studies including 54 journal articles and 3 abstracts were finally selected under the conditions of having clinical trials, FO, control condition, movement, scientific measuring system. The reviewed studies were divided into 10 categories according to subject characteristics; healthy normal, excessive pronation or flexible flat foot, rheumatoid arthritis, diabetes, medial knee osteoarthritis, forefoot varus, plantar fasciitis, patellofemoral syndrome, cavus foot and finite element model. In summary, first, soft and semirigid FOs with some degree of cushioning showed much higher comfort and efficacy than rigid FO. Second, no big differences between prefabricated and custom FO were shown. Third, the full length's FO was preferable to the half length's FO or simple arch supports. Fourth, the wearing of FO combining medial arch supports and metatarsal dome made positive roles to enhance comfort and functionality and redistribute plantar pressure under the foot. Fifth, for patients with knee-related diseases lateral wedges were preferable. Sixth, measuring systems were properly applied according to the types of foot diseases.

두 족저압 측정장비의 비교 분석 (Comparative Analysis of Two Pedobarography Systems)

  • 강호원;변수민;김대유;조윤재;경민규;이동연
    • 대한족부족관절학회지
    • /
    • 제28권1호
    • /
    • pp.21-26
    • /
    • 2024
  • Purpose: Foot pressure measurement devices are used widely in clinical settings for plantar pressure assessments. Despite the availability of various devices, studies evaluating the inter-device reliability are limited. This study compared plantar pressure measurements obtained from HR Mat (Tekscan Inc.) and EMED-n50 (Novel GmbH). Materials and Methods: The study involved 38 healthy male volunteers. The participants were categorized into two groups based on the Meary's angle in standing foot lateral radiographs: those with normal feet (angles ranging from -4° to 4°) and those with mild flatfeet (angles from -8° to -15°). The static and dynamic plantar pressures of the participants were measured using HR Mat and EMED-n50. The reliability of the contact area and mean force was assessed using the interclass correlation coefficient (ICC). Furthermore, the differences in measurements between the two devices were examined, considering the presence of mild flatfoot. Results: The ICC values for the contact area and mean force ranged from 0.703 to 0.947, indicating good-to-excellent reliability across all areas. EMED-n50 tended to record higher contact areas than HR Mat. The mean force was significantly higher in the forefoot region when measured with EMED-n50, whereas, in the hindfoot region, this difference was observed only during static measurements with HR Mat. Participants with mild flatfeet exhibited significantly higher contact areas in the midfoot region for both devices, with no consistent differences in the other parameters. Conclusion: The contact area and mean force measurements of the HR Mat and EMED-n50 showed high reliability. On the other hand, EMED-n50 tended to record higher contact areas than HR Mat. In cases of mild flatfoot, an increase in contact area within the midfoot region was observed, but no consistent impact on the differences between the two devices was evident.