• Title/Summary/Keyword: Food Wastewater Treatment Facility

Search Result 18, Processing Time 0.03 seconds

Characteristics of the Food Waste and Wastewater Discharged from Food Waste Treatment Process (음식물류폐기물 및 배출폐수의 특성)

  • Kim, Young-Kwon;Kim, Se-Mi;Kim, Min-Kyu;Choi, Jin-Taek;Nam, Se-Yong
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.6
    • /
    • pp.526-531
    • /
    • 2009
  • Waste generation was generally expected to steadily rise due to a rapid increase in population and economic growth. However, regulations on disposable goods and a volume-based waste fee system have led to a gradual reduction in the amount of waste. In the case of food waste, separation of food waste from other waste has been put in place since direct landfilling was banned in January 2005. The predicted generation amounts of food waste and wastewater in the model city were 54 ton/d and 127.3 ton/d by year 2020, respectively. However, appropriate treatment technologies for food waste and wastewater discharged from food waste treatment processes are yet to be established. In this study, the food waste and wastewater discharged from food waste treatment process in the model city were characterized by literal and field investigation.

A Study on Investigate the Suitability of ${NH_4}^+$ Applications of Food Waste Water Instead of Urea in the Incineration of Municipal Solid Waste (생활폐기물 소각시 요구되는 요소수의 대체물질로 음식물 폐수 속의 암모니아 적용에 관한 연구)

  • Go, Sung Gyoo;Cho, Yong Kun;Lee, Young Shin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.4
    • /
    • pp.97-105
    • /
    • 2012
  • This study examined for possibility of the food wastewater incineration treatment method as one of overland treatment method by incineration through liquefied spray of food wastewater when incinerating domestic wastes under operation and for the relationship, etc of air discharge material discharged in incineration, and the results of study are as follow: The food wastewater as one of overland treatment method was analysed 94-96% of moisture contents. Temperature of incinerator outduct during mixed incineration of food wastewater with MSW was average $897^{\circ}C$ and incineration of only MSW was $925^{\circ}C$. Temperature of the mixed incineration of food wastewater was dropped about $28^{\circ}C$ by incineration of only MSW. Concentration of nitrogen oxides(NOx) among air discharge gases was studied by 50ppm, 46ppm when inputting $200{\ell}/hr$, $300{\ell}/hr$ into the incinerator as the quantity of food wastewater. In the mixed incineration of food wastewater, generation speed of scales in the inside of a tubular exhaust gas boiler became rapid and the scale generation quantity became large but the exhaust gas boiler normally operated since scales were removed in cleaning of the tube with a compressive air cleaning facility and there was no opening clogging phenomena in a filter cloth of the filtering dust collector. The overland treatment method, not ocean dumping of food wastewater can be proposed as a technology since mixed incineration of food wastewater with MSW in the existing domestic waste incineration plant is possible, and operation costs of the incineration facility were reduced since use of chemicals such as ammonia and urinary hydrogen ion excretion, etc used in incineration facilities for removing nitrogen oxides(NOx).

Feasibility Study on the Treatment of Food Waste Leachate in Municipal Wastewater Treatment Facility - Case of P city - (음폐수 공공하수처리시설 연계처리 타당성 평가 - P시 사례 -)

  • Park, Jong-Hun;Kang, Shin-Young;Kim, Sang-Hyoun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.2
    • /
    • pp.41-49
    • /
    • 2016
  • P city government considers to treat a part of food waste leachate in a municipal wastewater treatment plant (MWWTP), as the capacity of an existing combined treatment plant for food waste leachate is lower than the generation of food waste leachate in the city. Furthermore, the combined treatment plant also treats landfill leachate and directly discharges the effluent to the sea, which may result in a potential environmental problem. Therefore, this study examined the feasibility of the addition of food waste leachate and the effluent of the combined treatment facility on the MWWTP. Acceptable addition amount of the food waste streams, increased pollution loading on the MWWTP, and the treatment cost were estimated according to four scenarios. All the scenarios estimated that the MWWTP would receive most of the food waste streams according to the manual of the ministry of environment with little increase of pollution loading.

Comparison of the unit mass discharge from wastewater treatment facility in the industrial park with the estimation methods (산업단지 폐수발생량 원단위 산정 비교연구)

  • Kim, Joon-Yup;Choi, Kyoung-Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.3
    • /
    • pp.339-344
    • /
    • 2014
  • The predictive capacity of wastewater treatment facility in the industrial park was estimated by the traditional method and on-the-spot survey such as certification of wastewater report and the invoices of water supply and ground water supply. The ratios of a converted wastewater to supplied industrial water between traditional method and on-the-spot survey in the estimation methods were different. By using traditional method, the business type of clothes, accessary and fur production had 77.18 % of waste ratio of wastewater and $10.72m^3/day{\cdot}1000m^2$ unit mass of wastewater as the highest among 9 business types. With the respect to the on-the-spot survey, food manufacturing business type had 75 % of waste ratio of wastewater and $8.35m^3/day{\cdot}1000m^2$ unit mass of wastewater as the highest values. The amount of wastewater from on-the-spot survey method was 541 $m^3/day$ less than one from traditional method.

Isolation and Characterization of Ammonia-removing Bacteria from a Food-wastewater Treatment Facility (식품 폐수 처리 시설에서 암모니아성 악취제거 세균의 분리 및 특성 분석)

  • Oh, Kyoung-Hee;Choi, In-Hak;Cho, Young-Cheol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.6
    • /
    • pp.653-658
    • /
    • 2008
  • The bacteria responsible for the reduction of ammonia concentration in a food-wastewater treatment facility were isolated and their characteristics were analyzed. The isolated bacteria were closely related to the bacteria belonging to genus Citrobacter, Enterobacter, Buttiauxella, Shigella, and Aeromonas, which were found in gut of animals, indicating the isolated bacteria may come from the butchery-byproduct of pigs which is the main component of wastewater. When we monitored the concentration of nitrite and nitrate in the process, it was relatively constant, indicating the isolated bacteria reduce ammonia concentration through ammonia assimilation. Based on the removal efficiency of ammonia by the isolated bacteria, we concluded that they play a role in the reduction of odorous compounds.

A Study on the Improvement of Effluent Treatment from Small Scale Agro-food Processes (소규모 농산가공시설 배출수 처리시설 개선방안)

  • Kim, Youngjin;Jeon, Jonggil;Kim, Minyoung;Choi, Yonghun
    • Journal of Agricultural Extension & Community Development
    • /
    • v.23 no.4
    • /
    • pp.361-374
    • /
    • 2016
  • This study examined the regulation status on wastewater treatment in agro-food processing and a case study on effluent treatment m ethods was carried out to evaluate any change after the mitigation of regulation. First, in order to clarify the area of investigation, the definition of small-scale agro-processing facilities was reviewed through literature survey and local government ordinance. The current law were separately analyzed into four areas; effluent treatment facilities, development of agro-processing industries, land use and food processes equipment. The exclusion clauses on wastewater discharging facility in the enforcement regulation were defined in detail, which can be served in practice. Site survey, after the questionnaire survey of the person in charge of the local unit, was carried out. As the result, this survey confirmed the positive effects of the deregulation on promoting sewer system service in rural areas, introducing the new processing construction and so on. In addition, it was found that some matters to be considered to determine whether to introduce wastewater treatment plan for public food processing facilities.

Influence of Effluent from a Sludge Carbonization Facility on Wastewater Treatability (슬러지탄화공정수 연계처리가 하수처리효율에 미치는 영향)

  • Han, Joo Eun;Park, Soo-Hyung;Lee, Wontae
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.1
    • /
    • pp.57-64
    • /
    • 2019
  • We investigated influence of connected influent on the treatability of a wastewater treatment plant (WWTP), recently accepting effluent from a sludge carbonization facility. Based upon the pollutant loading rates (kg/d) of each connected influent, food waste leachate and livestock wastewater contributed to high BOD and COD loadings, while sludge carbonization facility effluent certainly contributed to T-N and $NH_3-N$ loadings. The nitrification rate in aerobic tank decreased to 55% with the carbonization facility effluent entering to the WWTP, while it was 89% with no carbonization facility effluent entering. The sludge carbonization facility effluent may need to be pretreated to reduce T-N and $NH_3-N$ loadings before entering to the WWTP for further treatment.

Technical Evaluation of MBR Process for the Wastewater Treatment of Beverage Fabrication Processes (음료수 제조 공정 폐수의 MBR 처리 기술 평가)

  • Jung, Cheol Joong;Park, Jong Min;Kim, Youn Kook
    • Membrane Journal
    • /
    • v.24 no.1
    • /
    • pp.63-68
    • /
    • 2014
  • Manufacturing facility for non-alcoholic drink, the parts of the food industry, disposes wastewater which includes high organic concentration and low nitrogen, phosphorus concentration. For this kind of wastewater, the treatment plant consists mainly of aerobic reactor and chemical coagulation process. And sand-filter or activated carbon process is normally installed further. However, aerobic reactor must have long HRT to treat high concentration of organic contaminant included in this wastewater, so the large site area is required. And settling tank which is normally applied for wastewater treatment facility has some problems such as water quality degradation caused by the sludge spill. To solve these problems, we applied MBR system for the wastewater. And the MBR pilot plant was installed nearby the wastewater treatment facility of W food factory and operated during long term to evaluate treatment efficiency. This plant was operated about 3 months and than the result was 97% of organic removal rate on conditions of flow rate $20m^3/day$, HRT 29 hr, recycle 4Q. However, contaminant removal ratio of bio-reactor decreased and TMP of membrane increased rapidly on more conditions.

Estimation of GHGs Emission to Improvement of Facility Efficiency in the Food wastewater Treatment Process (식품폐수처리시설의 설비효율 개선에 따른 온실가스 배출량 평가)

  • An, Sang-Hyung;Song, Jang-Heon;Kim, San;Chung, Jin-Do
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.378-384
    • /
    • 2019
  • In the food wastewater treatment facilities, the water quality improvement effect and the greenhouse gas emission amount followed by the change in electricity usage through a change of the aeration tank ventilation system were evaluated. also, the amount of greenhouse gas emission followed by the change in electricity usage through the change of the sludge dewatering, storage, transporting method was also evaluated. The total GHG emission from food wastewater treatment facility improvement were divided into direct emissions from the treatment processes and indirect ones from electricity usage. The water quality improvement effect of wastewater treatment plant was found to be 63.3% for BOD removal rate, 42.0% for COD removal rate, 71.0% for SS removal rate and 39.6% for T-N removal rate. and according to the results of calculating output by applying both direct emissions of greenhouse gas (Scope 1) and the indirect emission (Scope 2) of greenhouse gas followed by changes in power consumption. It was estimated that there was a total of 276.0tCO2eq./yr(7.5%) greenhouse gas reduction effect from 3,668.8tCO2eq./yr before improvement to 3,392.8tCO2eq./yr after improvement. In this result is not due to the effects of water quality improvement of emission source, but because the reduction in electricity use has reduced the amount of greenhouse gas emissions.

A Study on Improvement of Distribution Facility in Wholesale Agricultural Products Market

  • Gal, Won-Mo;Kwon, Ki-Tae;Lee, Woo-Sik;Choi, Eun-Mee;Kwon, Lee-Seung;Seong, Seung-Hwan;Kwon, Woo-Taeg
    • Journal of Distribution Science
    • /
    • v.16 no.2
    • /
    • pp.53-65
    • /
    • 2018
  • Purpose - The purpose of this study is to investigate the effect of gamma - irradiation on the effluent from food distribution in the large agricultural and marine products market. This study will contribute to the distribution process as well as the agricultural and fishery distribution facilities. Research design, data, and methodology - In order to reduce the odor, the smell was examined in the anaerobic digestion process by irradiating gamma rays to the wastewater of mixed food discharged from a large restaurant. An odor determination panel list was constructed to determine if the odor was present in the air dilution drainage and the odor concentration was analyzed by instrumental analysis. Results - It was confirmed that the sulfur content increased gradually from 3 months. Ammonia decreased from 33.57ppm at the initial measurement to 4.12 ppm at the end of the experiment. Methane production was highest at 100kGy when exposed to gamma rays of 0-200kGy at pH 12. In other words, it is considered that gamma irradiation doses are most effective at 100kGy and are suitable for large capacity wastewater treatment facilities in terms of economic feasibility. Conclusions - In pre-treatment of compound food wastewater, gamma irradiation is most cost effective when examined at 100kGy. The economic efficiency of the pre-treatment method by gamma irradiation is much higher than the wastewater treatment in the large-scale agricultural and marine products distribution market.