• Title/Summary/Keyword: Focus-Detector Distance

Search Result 14, Processing Time 0.032 seconds

Reducing Methods of Patient's Exposed Dose Using Auto Exposure Control System in Digital Radiography (디지털 방사선장비에서 자동노출제어 사용 시 환자피폭선량 감소 방안)

  • Shin, Seong-Gyu
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.111-122
    • /
    • 2013
  • This study was carried out to reduce patient dose through focus-detector distance, kilovoltage, and a combination of copper filters. In the C, L-spine lateral, Skull AP views were obtained by making changes of 60-100 kV in tube voltage and of 100-200 cm in focus-detector distance and by adding a copper filter when using an auto exposure control device in the digital radiography equipment. The incident dose showed 90 kV, 0.3 mmCu in C-spine lateral with 0.06 mGy under the condition of 200 cm; 100 kV, 0.3 mmCu with 0.40 mGy under the condition of 200 cm and 90 kV 0.3 mmCu in Skull AP with the lowest value of 0.24 mGy under the condition of 140 cm. It was observed that entrance surface dose decreased the most when was increased by 150 cm, 70 kV (C-spine lateral), 81 kV (L-spine lateral). It was also found out that as the between the focus-detector increased in the expansion of the video decreased but the difference was not significant when the distance was 180 cm or more. Skull AP showed the most reduction in the entrance surface dose when the tube voltage was changed by 80 kV, 0.1 mmCu, and 120 cm. Therefore, when using the automatic exposure control device, it is recommended to use the highest tube voltage if possible and to increase focus-detector distance at least by 150~200 cm in wall and 120~140 cm in table in consideration of the radiotechnologist's physical conditions, and to combine 0.1~0.3 mmCu and higher filters. It is thus expected to reduce patient dose by avoiding distortion of images and reducing the entrance surface dose.

The Influence of the Change of Patient Radiation Exposure Dose Distribution on the Grid Condition and Detector Acquisition Dose on the Exposure Distance in the Use of Amorphous Silicon Thin Film Transistor Detector with AEC (자동노출제어장치를 이용한 비정질 실리콘 평판형 검출기에서 격자의 조건에 따른 환자선량 변화와 촬영 거리의 변화가 검출기 획득선량에 미치는 영향)

  • Yoon, Seok-Hwan;Choi, Jun-Gu;Han, Dong-Kyoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.23-30
    • /
    • 2007
  • This study attempts to propose an appropriate method of using digital medical imaging equipments, by studying the effects of automatic exposure control(AEC), grid ratio and the change of radiography distance on the patient dose and detertor acquisition dose during the procedure of acquiring image through a digital medical imaging detector. The change of dose following the change of grid ratio's exposure and radiography distance was measured, by using an abdominal phantom organized with tissue equivalent materials in an amorphous silicon thin film transistor detecter installed with AWC. The case to use grid ratio 12 : 1, focal distance 180cm to radiography distance 110cm in AEC, the patient dose increased rather when we used grid ration 10 : 1, focal distance 110cm. When AEC was not used,the dose necessary for image acquisition decreased as the grid ratio became higher and the distance became further. but detector acquisition dose was not reduced when in applied AEC. When purchasing digiral medical imaging equipments, optional items such as AEC and grid shall be accurately selected to satisfy the use of the equipments. Radiography error made by radiation technologist and unnenessary patient dose can be reduced by selecting equipments with a radiography distance marker equipment when it did not apply AEC. These equipments can also be helpful in maintaining high imaging quality, one of the merits of digital detectors.

  • PDF

A Study on High-precision Autofocus Matching Device for Smoke Detector Based on IR Laser (IR 레이저 기반 연기감지기를 위한 고정밀 자동초점 정합장치에 관한 연구)

  • Kim, Gwan-Hyung;Shin, Dong-Suk;Oh, Am-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.11
    • /
    • pp.2759-2764
    • /
    • 2014
  • Smoke detector is commonly used to reduce fire detection time. However, technical problems regarding its inaccuracy of laser beam-receiving point on the surface of the sensor associated with incoming interference are identified when the laser transmitter and receiver are installed at a distance of about 100m. In this paper, we propose the auto focus alignment algorithm with high precision to adjust tilting angle of lasers caused by environmental interference so that solve existing issues using multi-level worm gear set.

Zoom-in X-ray Micro Tomography System

  • Chun, In-Kon;Lee, Sang-Chul;Park, Jeong-Jin;Cho, Min-Hyoung;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.5
    • /
    • pp.295-300
    • /
    • 2005
  • We introduce an x-ray micro tomography system capable of high resolution imaging of a local region inside a small animal. By combining two kinds of projection data, one from a full field-of-view (FOV) scan of the whole body and the other from a limited FOV scan of the region of interest, we have obtained zoomed-in images of the region of interest without any contrast a nomalies. We have integrated a micro tomography system using a micro-focus x-ray source, a $1248\times1248$ flat-panel x-ray detector, and a precision scan mechanism. Using the cross-sectional images taken with the zoom-in micro tomography system, we measured trabecular thicknesses of femur bones in postmortem rats. To compensate the limited spatial resolution in the zoom-in micro tomography images, we used the fuzzy distance transform for the calculation of the trabecular thickness. To validate the trabecular thickness measurement with the zoom-in micro tomography images, we compared the measurement results with the ones obtained from the conventional micro tomography images of the extracted bone samples.

A Design of Real-time Automatic Focusing System for Digital Still Camera Using the Passive Sensor Error Minimization (수동 센서의 오차 최소화를 이용한 실시간 DSC 자동초점 시스템 설계)

  • Kim, Geun-Seop;Kim, Deok-Yeong;Kim, Seong-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.5
    • /
    • pp.203-211
    • /
    • 2002
  • In this paper, the implementation of a new AF(Automatic Focusing) system for a digital still camera is introduced. The proposed system operates in real-time while adjusting focus after the measurement of distance to an object using a passive sensor, which is different from a typical method. In audition, measurement errors were minimized by using the data acquired empirically, and the optimal measuring time was obtained using EV(Exposure Value) which is calculated from CCD luminance signal. Moreover, this system adopted an auxiliary light source for focusing in absolute dark conditions, which is very hard for CCD image Processing. Since this is an open-loop system adjusting focus immediately after the distance measurement, it guarantees real-time operation. The performance of this new AF system was verified by comparing the focusing value curve obtained from AF experiment with the one from the measurement by MF(Manual-Focusing). In both case, edge detector was used for various objects and backgrounds.

Change of PAE according to Detector Measurement Method (검출기 측정방법에 따른 PAE값의 변화)

  • Im, In-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.307-311
    • /
    • 2010
  • The aim of this study is to investigate PAE, as the result of the test of kVp accuracy, according to detector measurement method. Based on the indicated value of 70kVp, each distance between a focus and a kVp meter was 100cm, 80cm and 60cm and the angle of X-ray tube was set on $5^{\circ},\;10^{\circ},\;15^{\circ},\;20^{\circ},\;25^{\circ},\;30^{\circ}$. Each indicated value, 60kVp, 70kVp, 80kVp, 90kVp and 100 kVp, was used compare Small focus with Large focus. As a result, PAE on the side of cathode was higher than it on the side of anode in the case of 100cm and PAE on the side of anode was higher in the case of 80cm and 60cm. The coefficient rate was stable both the side of cathode and anode in the case of 100cm and it was fluctuated in the case of 80cm and 60cm. PAE in the case of Small focus was higher than Large focus and it was disproportionate to an indicated value. Error rate was in inverse proportion to the indicated value.

Study on the Exposure Dose(mAs) and acquisition Image set up Density Display and Sensitivity of control Panel for the Digital Flat-Panel-Detector (디지털 평판형 검출기에서 Control Panel의 Density Display와 Sensitivity 설정이 조사선량(mAs)과 획득영상에 미치는 영향에 관한 연구)

  • Kim, Byung-Ki;Kim, Sang-Keun;Cha, Seon-Hwa;Choi, Jun-Gu;Lee, Jun;Kim, Min-Woo;Kim, Sun-Bae;Kim, Gyeong-Sun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.17-21
    • /
    • 2007
  • The purpose to recognize change of average pixel value of acquisition image by control panel's density and right set up method of speed (sensitivity) and exposure dose(mAs) change that dose in purpose digital flatpanel-detector. X -ray generator DHF-158H2(Hitachi, Japan). Detector CXDI 4OG(Canon, Japan), 12 : 1 grid and exposure ray 135 kVp, 250 mA, 10 ms. focus-detector distance 180 cm and used AEC mode. DICOM reflex analysis program used image J that is digital reflex analysis program that offer in United States America National Health Center(National Institutes of Health : NlH) phantom used chest phantom(Anthromorphic : Flukebrome.medicaI USA). An experiment chest phantom that consist by formation equivalence material use because density value( -3${\sim}$+3) in X-ray control panel and seep that is speed step(slow, medium, fast) each control experimentalize. image analysis reflex neted through an experiment using image j each image compare. These was change in dose according to slow, medium, fast and density's change in an experiment result. According to detector sensitivity and density condition set, dose was relationship dissimilarity 500% from 200%. The dose came highest when is density +3 to slow. and dose more increases gray scale's extent could know that rise. Could know whether how equipment set is important through this experiment. cause of disease which change by digital radiography system forward is thought to increase more, it is considered that suitable education by this and continuous interest about equipment need absolutely.

  • PDF

An Analysis of Factors That Affect Image Quality Deterioration in The Potable X-ray Examination on using Digital Wireless Detector (디지털 무선 검출기를 이용한 이동형 X선검사에서 영상품질 저하의 요인분석)

  • Yu, Young-Eun;Lim, Cheong-Hwan;Ko, Joo-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.93-100
    • /
    • 2014
  • Recently the development of portable digital wireless imaging system, which acquires digital radiation images by using wireless LAN telecommunications function in an easy and fast way, provides lots of convenience for people. Considering the characteristics of portable imaging tests on emergency and critical patients, this study aims to suggest guidelines for Digital wireless detector by evaluating the effect of de-centering of focus-grid and displacement of subject in detector on the quality of image. The equipments used for this study were Elmo-T6 Digital Mobile X-ray system (SIMAZU Corp.), el' Tor ($14{\times}17$ "Wireless detector), Grid (10:1) and Chest & head phantom. After acquiring post-processing image according to dose increase and de-centering image of grid-focus and head phantom displacement image, this study compared, analyzed and evaluated these images by using a digital image analysis program by Image J. In the change of images based on dose increase, images were rough in the dose of 0.5 mAs, while there was no difference among images in the proper dose of 1~2 mAs and, especially from 2.5 mAs, average value of pixels radically decreased, affecting contrast. Over 3 mAs, contrast dropped due to saturation phenomenon of lungs. As the result of analysis using Image J program, with the increase of displacement between focus-grid and head phantom, the frequency of low pixel value also increase, causing the outline of surface image to disappear, which in turn affects contrast. For better quality imaging, a radiographer must be aware before the time of test that the image quality can be changed based on the critical patient's posture, movement, respiration, displacement of X-ray tube and distance of imaging.

Survey of Technical Parameters for Pediatric Chest X-ray Imaging by Using Effective DQE and Dose (유효검출양자효율과 선량을 이용한 소아 흉부 X-선 영상의 기술적인 인자에 관한 조사)

  • Park, Hye-Suk;Kim, Ye-Seul;Kim, Sang-Tae;Park, Ok-Seob;Jeon, Chang-Woo;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.163-171
    • /
    • 2011
  • The purpose of this study was to investigate the effect of various technical parameters for the dose optimization in pediatric chest radiological examinations by evaluating effective dose and effective detective quantum efficiency (eDQE) including the scatter radiation from the object, the blur caused by the focal spot, geometric magnification and detector characteristics. For the tube voltages ranging from 40 to 90 kVp in 10 kVp increments at the FDD of 100, 110, 120, 150, 180 cm, the eDQE was evaluated at the same effective dose. The results showed that the eDQE was largest at 60 kVp when compares the eDQE at different tube voltage. Especially, the eDQE was considerably higher without the use of an anti-scatter grid on equivalent effective dose. This indicates that the reducing the scatter radiation did not compensate for the loss of absorbed effective photons in the grid. When the grid is not used the eDQE increased with increasing FDD because of the greater effective modulation transfer function (eMTF). However, most of major hospitals in Korea employed a short FDD of 100 cm with an anti-scatter grid for the chest radiological examination of a 15 month old infant. As a result, the entrance surface air kerma (ESAK) values for the hospitals of this survey exceeded the Korean DRL (diagnostic reference level) of $100{\mu}Gy$. Therefore, appropriate technical parameters should be established to perform pediatric chest examinations on children of different ages. The results of this study may serve as a baseline to establish detailed reference level of pediatric dose for different ages.

GC Capillary Column Installation (가스 크로마토그래피 캐필러리 컬럼 설치 가이드)

  • Matt James;Kirsty Ford
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.2.1-2.6
    • /
    • 2024
  • This article provides detailed instructions for the correct installation, maintenance, and troubleshooting of capillary gas chromatography (GC) columns. It emphasizes the importance of proper installation to ensure optimal performance and longevity of the column. The document covers various aspects such as column trimming, installation, conditioning, testing, storage, and ferrule selection. The installation process involves ensuring that the heated zones of the GC are cool before placing the column cage in the column oven. It is essential to avoid sharp bends or stress on the capillary column during installation and to connect the front end of the column into the GC inlet at the recommended insertion distance. The document also provides guidance on trimming the column, including the use of a ceramic wafer or capillary column cutter to achieve a clean, burr-free cut. For previously used columns, it recommends removing any capillary caps, positioning the nut and ferrule, and trimming 1-2 cm from the column. After installation, the column should be purged with carrier gas to remove any oxygen and avoid oxidizing the column. Conditioning the column involves ramping to the upper isothermal temperature limit and maintaining this temperature for a specified duration. It is crucial to maintain carrier gas flow during conditioning and not exceed the upper temperature limit of the column to avoid phase damage. The document also discusses testing column performance using a suitable method and performing a test injection to assess performance. It provides recommendations for column storage, including flame-sealing the capillary ends or using retention gaps for long-term storage. Additionally, it emphasizes the importance of routine maintenance and replacement of GC consumables to extend the column's lifetime. Ferrule selection is another important aspect covered in the article, with a variety of ferrule materials available for different applications. The characteristics of common ferrule options are presented in a table, including temperature limits, reusability, and suitability for specific detector types.

  • PDF