• Title/Summary/Keyword: Focal plane

Search Result 260, Processing Time 0.025 seconds

Pixel-level Current Mirroring Injection with 2-step Bias-current Suppression for 2-D Microbolometer FPAs (이차원 마이크로볼로미터 FPA를 위한 이 단계 바이어스 전류 억제 방식을 갖는 픽셀 단위의 전류 미러 신호취득 회로)

  • Hwang, Chi Ho;Woo, Doo Hyung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.11
    • /
    • pp.36-43
    • /
    • 2015
  • A pixel-level readout circuit is studied for 2-dimensional microbolometer focal plane arrays (FPAs). A current mirroring injection (CMI) input circuit with 2-step current-mode bias suppression is proposed for a pixel-level architecture with high responsivity and long integration time. The proposed circuit has been designed using a $0.35-{\mu}m$ 2-poly 4-metal CMOS process for a $320{\times}240$ microbolometer array with a pixel size of $50{\mu}m{\times}50{\mu}m$. The proposed 2-step bias-current suppression has sufficiently low calibration error with wide calibration range, and the calibration range and error can be easily optimized by controlling some design parameters. Due to high responsivity and a long integration time of more than 1 ms, the noise equivalent temperature difference (NETD) of the proposed circuit can be improved to 26 mK, which is much better than that of the conventional circuits, 67 mK.

Analysis of the MSC(Multi-Spectral Camera) Operational Parameters

  • Yong, Sang-Soon;Kong, Jong-Pil;Heo, Haeng-Pal;Kim, Young-Sun
    • Korean Journal of Remote Sensing
    • /
    • v.18 no.1
    • /
    • pp.53-59
    • /
    • 2002
  • The MSC is a payload on the KOMPSAT-2 satellite to perform the earth remote sensing. The instrument images the earth using a push-broom motion with a swath width of 15 km and a GSD(Ground Sample Distance) of 1 m over the entire FOV(Field Of View) at altitude 685 km. The instrument is designed to haute an on-orbit operation duty cycle of 20% over the mission lifetime of 3 years with the functions of programmable gain/offset and on-board image data compression/storage. The MSC instrument has one channel for panchromatic imaging and four channel for multi-spectral imaging covering the spectral range from 450nm to 900nm using TDI(Time Belayed Integration) CCD(Charge Coupled Device) FPA(Focal Plane Assembly). The MSC hardware consists of three subsystem, EOS(Electro Optic camera Subsystem), PMU(Payload Management Unit) and PDTS(Payload Data Transmission Subsystem) and each subsystems are currently under development and will be integrated and verified through functional and space environment tests. Final verified MSC will be delivered to spacecraft bus for AIT(Assembly, Integration and Test) and then COMSAT-2 satellite will be launched after verification process through IST(Integrated Satellite Test). In this paper, the introduction of MSC, the configuration of MSC electronics including electrical interlace and design of CEU(Camera Electronic Unit) in EOS are described. MSC Operation parameters induced from the operation concept are discussed and analyzed to find the influence of system for on-orbit operation in future.

The Ground Checkout Test of OSMI on KOMPSAT-1

  • Yong, Sang-Soon;Shim, Hyung-Sik;Heo, Haeng-Pal;Cho, Young-Min;Oh, Kyoung-Hwan;Woo, Sun-Hee;Paik, Hong-Yul
    • Korean Journal of Remote Sensing
    • /
    • v.15 no.4
    • /
    • pp.297-305
    • /
    • 1999
  • Ocean Scanning Multispectral Imager (OSMI) is a payload on the KOMPSAT satellite to perform global ocean color monitoring for the study of biological oceanography. The instrument images the ocean surface using a wisk-broom motion with a swath width of 800km and a ground sample distance (GSD) of < 1km over the entire field of view (FOV). The instrument is designed to have an on-orbit operation duty cycle of 20% over the mission lifetime of 3 years with the functions of programmable gain/offset and on-board image data compression/storage. The instrument also performs sun and dark calibration for on-board instrument calibration. The OSMI instrument is a multi-spectral imager covering the spectral range from 400nm to 900nm using CCD Focal Plane Array (FPA). The ocean colors are monitored using 6 spectral channels that can be selected via ground commands. KOMPSAT satellite with OSMI was integrated and the satellite level environment tests including instrument aliveness/functional test, such as launch environment, on-orbit environment (Thermal/Vacuum) and EMI/EMC test were performed at KARl. Test results met the requirements and the OSMI data were collected and analyzed during each test phase. The instrument is launched on the KOMPSAT satellite on December 21,1999 and is scheduled to start collecting ocean color data in the early 2000 upon completion of on-orbit instrument checkout.

Focal point construction of ellipses using analogy and analytical methods (유추와 분석적 방법을 활용한 타원 초점 작도)

  • Kim, Keun-Bae;Choi, Ok-Whan;Park, Dal-Won
    • Journal of the Korean School Mathematics Society
    • /
    • v.21 no.4
    • /
    • pp.401-418
    • /
    • 2018
  • The current geometric and vector textbooks focus on the mechanical activities of finding focus, corner, etc. through elliptic equations. In this paper, we propose a process in which analogy and analytical methods are used in reversible activities of focusing from a given elliptic graph without a coordinate plane. The exploratory tool was used as Geogebra. At first, students tried to find the focus of the ellipse by randomly constructing the major a is and the minor a is in the given ellipse. However, we have experienced a method of constructing the circle of symmetry and analyzed this principle and deduced it to the ellipse. As a result, we could construct the center, long a is and short a is of the ellipse. Then, using the analytical method, the focus formula was recognized as the Pythagorean theorem, and the ellipse's focus was constructed by using the original drawing. Therefore, it is confirmed that analogy and analytical method can positively affect the elliptical focus.

Depth Generation using Bifocal Stereo Camera System for Autonomous Driving (자율주행을 위한 이중초점 스테레오 카메라 시스템을 이용한 깊이 영상 생성 방법)

  • Lee, Eun-Kyung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1311-1316
    • /
    • 2021
  • In this paper, we present a bifocal stereo camera system combining two cameras with different focal length cameras to generate stereoscopic image and their corresponding depth map. In order to obtain the depth data using the bifocal stereo camera system, we perform camera calibration to extract internal and external camera parameters for each camera. We calculate a common image plane and perform a image rectification for generating the depth map using camera parameters of bifocal stereo camera. Finally we use a SGM(Semi-global matching) algorithm to generate the depth map in this paper. The proposed bifocal stereo camera system can performs not only their own functions but also generates distance information about vehicles, pedestrians, and obstacles in the current driving environment. This made it possible to design safer autonomous vehicles.

Quasi-monochromatic Parallel Radiography Achieved with a Polycapillary Plate

  • Sato, Eiichi;Komatsu, Makoto;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Ichimaru, Toshio;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.418-421
    • /
    • 2002
  • Fundamental study on quasi-monochromatic parallel radiography using a polycapillary plate and a plane-focus x-ray tube is described. The x-ray generator consists of a negative high-voltage power supply, a filament (hot cathode) power supply, and an x-ray tube. The negative high-voltage is applied to the cathode electrode, and the transmission type target (anode) is connected to the ground potential. The maximum voltage and current of the power supply were -100 kV (peak value) and 3.0 mA, respectively. In this experiment, the tube voltage was regulated from 20 to 25 kV, and the tube current was regulated by the filament temperature and ranged from 1.0 to 3.0 mA. The exposure time is controlled in order to obtain optimum film density, and the focal spot diameter was about 10 mm. The polycapillary plate is J5022-21 made by Hamamatsu Photonics Inc., and the outside and effective diameters are 87 and 77 mm, respectively. The thickness and the hole diameter of the polycapillary are 1.0 mm and 25 ${\mu}$m, respectively. The x-rays from the tube are formed into parallel beam by the polycapillary, and the radiogram is taken using an industrial x-ray film of Fuji IX 100 without using a screen. In the measurement of image resolution, we employed three brass spacers of 2, 30, and 60 mm in height. By the test chart, the resolution fell according to increases in the spacer height without using a polycapillary. In contrast, the resolution slightly fell with corresponding increases in the height by the polycapillary. In angiography, fine blood vessels of about 100 ${\mu}$m are clearly visible.

  • PDF

Statistical Analysis of Focus Adjustment Method for a Floating Imaging System with Symmetric Error Factors (대칭형 공차를 갖는 플로팅 광학계의 상면 변화 보정 방법에 대한 통계적 해석)

  • Ryu, Jae Myung;Kim, Yong Su;Jo, Jae Heung;Kang, Geon Mo;Lee, Hae Jin;Lee, Hyuck Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.5
    • /
    • pp.189-196
    • /
    • 2012
  • A floating optical system is a system that moves more than 2 groups to focus at the camera lens. At the camera optics, the floating system that is mainly used is an optical system such as a macro lens which changes magnification very much. When the floating system is assembled and fabricated in the factory, there are differences between the image plane of the sensor and the focal plane of the infinity or macro state. Therefore, in a considerable proportion of cases, the focus adjustment to minimize the difference of BWD(Back Working Distance) is carried out in the process of manufacturing. In this paper, in order to decide the movement of each group in a floating system, we evaluated the rotation angle of CAM for the focus adjustment. We know that the maximum magnification of macro state is corrected by this numerical method for the focus adjustment, too. We investigated the limit of CAM rotation angle of the system by using statistical analysis for CAM rotation angle, which uses the focus adjustment of the floating system with symmetric error factors.

Geospatial Data Display Technique for Non-Glasses Stereoscopic Monitor (무안경식 입체 모니터를 이용한 지형공간 데이터의 디스플레이 기법)

  • Lee, Seun-Geun;Lee, Dong-Cheon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.6
    • /
    • pp.599-609
    • /
    • 2008
  • Development of computer and electronic technology leads innovative progress in spatial informatics and successful commercialization. Geospatial information technology plays an important role in decision making in various applications. However, information display media are two-dimensional plane that limits visual perception. Understanding human visual processing mechanism to percept stereo vision makes possible to implement three-dimensional stereo image display. This paper proposes on-the-fly stereo image generation methods that are involved with various exterior and camera parameters including exposure station, viewing direction, image size, overlap and focal length. Collinearity equations and parameters related with stereo viewing conditions were solved to generate realisitc stereo imagery. In addition stereo flying simulation scenery was generated with different viewing locations and directions. The stereo viewing is based on the parallax principle of two veiwing locations. This study implemented anaglyphic stereogram, polarization and lenticular stereo display methods. Existing display technology has limitation to provide visual information of three-dimensional and dynamic nature of the real world because the 3D spatial information is projected into 2D plane. Therefore, stereo display methods developed in this study improves geospatial information and applications of GIS by realistic stereo visualization.

INTEGRATED RAY TRACING MODEL FOR END-TO-END PERFORMANCE VERIFICATION OF AMON-RA INSTRUMENT (AMON-RA 광학계를 활용한 통합적 광선 추적 기법의 지구 반사율 측정 성능 검증)

  • Lee, Jae-Min;Park, Won-Hyun;Ham, Sun-Jeong;Yi, Hyun-Su;Yoon, Jee-Yeon;Kim, Sug-Whan;Choi, Ki-Hyuk;Kim, Zeen-Chul;Lockwood, Mike
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.1
    • /
    • pp.69-78
    • /
    • 2007
  • The international EARTHSHINE mission is to measure 1% anomaly of the Earth global albedo and total solar irradiance using Amon-Ra instrument around Lagrange point 1. We developed a new ray truing based integrated end-to-end simulation tool that overcomes the shortcomings of the existing end-to-end performance simulation techniques. We then studied the in-orbit radiometric performance of the breadboard Anon-Ra visible channel optical system. The TSI variation and the Earth albedo anomaly, reported elsewhere, were used as the key input variables in the simulation. The output flux at the instrument focal plane confirms that the integrated ray tracing based end-to-end science simulation delivers the correct level of incident power to the Amon-Ra instrument well within the required measurement error budget of better than ${\pm}0.28%$. Using the global angular distribution model (ADM), the incident flux is then used to estimate the Earth global albedo and the TSI variation, confirming the validity of the primary science cases at the L1 halo orbit. These results imply that the integrated end-to-end ray tracing technique, reported here, can serve as an effective and powerful building block of the on-line science analysis tool in support of the international EARTHSHINE mission currently being developed.

Design of Low Noise Readout Circuit for 2-D Capacitive Microbolometer FPAs (정전용량 방식의 이차원 마이크로볼로미터 FPA를 위한 저잡음 신호취득 회로 설계)

  • Kim, Jong Eun;Woo, Doo Hyung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.10
    • /
    • pp.80-86
    • /
    • 2014
  • A low-noise readout circuit is studied for 2-D capacitive microbolometer focal plane arrays (FPAs). In spite of the merits of the integration method, a simple and effective pixelwise readout circuit without integration is used for input circuit because of a small pixel size and narrow noise bandwidth. To reduce the power consumption and the kT/C noise, which is the dominant noise of the capacitive microbolometer FPAs with small capacitance, a new correlated double sampling (CDS) is used for columnwise circuit. The proposed circuit has been designed using a $0.35-{\mu}m$ 2-poly 4-metal CMOS process for a microbolometer array with a pixel size of $50{\mu}m{\times}50{\mu}m$. The proposed circuit effectively reduces the kT/C noise and the other low-frequency noise of microbolometer, and the noise characteristics of the fabricated chip have been verified by measurements. The rms noise voltage of the proposed circuit is reduced from 30 % to 55 % compared to that of the simple readout input circuit, and the noise equivalent temperature difference (NETD) of the proposed circuit is very low value of 21.5 mK.