• 제목/요약/키워드: Focal length

검색결과 377건 처리시간 0.035초

접시형 태양열 집광 시스템의 에너지 분포 특성에 관한 연구 (A Study on Energy Distributions Produced by Dish Solar Concentrating System)

  • 현성택;강용혁;천원기
    • 설비공학논문집
    • /
    • 제14권11호
    • /
    • pp.907-913
    • /
    • 2002
  • An experimental study on energy density distributions produced by dish solar concentrating system was performed to optimally design and rightly position a cavity receiver. This deemed also very useful to find and correct various errors associated with a concentrator. It is observed that the actual focal length is 2.17 m with a maximum energy density of 1.89 MW/$m^2$. By evaluating the position of flux centroid, it was found that there are errors within 2 cm from the target center. As a result of the percent power within radius, approximately 90% of the incident radiation is intercepted by about 0.06 m radius. The area concentration ratio normalized to 800 W/$m^2$ insolation and 90% mirror reflectivity was 347 suns. The total integrated power of 2467 W was measured under focal flux distributions, which corresponds to the intercept rate of 85.8%.

원고리형 레이저광에 의한 근사 무회절 광의 발진 (Generation of non-diffraction beam with annular laser output beam)

  • 김현태;박대윤;김기식
    • 한국광학회지
    • /
    • 제12권6호
    • /
    • pp.496-502
    • /
    • 2001
  • Scraper 출력경을 이용하는 불안전 공진기형 Nd:YAG 레이저 발진기에서 고리 두께 0.145mm인 원고리형 레이저광을 얻었으며, 초점거리에 위치한 베셀렌즈를 통과시켜 근사 무회절 광을 얻었다. 초점거리 1 m의 렌즈를 이용하여 얻은 근사 무회절 광에 대해서 렌즈로부터 거리 z의 변화에 따른 출력세기를 측정하여 이론과 비교 ·분석하였다. 또한 초점거리 5m의 렌즈를 이용한 경우, 거리 33m의 지점에서도 근사 무회절광이 지속됨을 확인하였다

  • PDF

한국어의 발화 길이 및 절 경계와 초점에 의한 점진하강(declination) 연구 (A Study on the Declination According to Length of Utterance, Clause Boundary and Focus in Korean)

  • 곽숙영
    • 말소리와 음성과학
    • /
    • 제2권3호
    • /
    • pp.11-22
    • /
    • 2010
  • The present study attempts to investigate declination in Korean and its relevant aspects to the length of utterance, the clause boundary, and focus. More specifically, I examine the relation of declination with the length of utterance, the declination reset at the clause boundary, and the effect of focus on declination. Results showed that the length of utterance had no relation with the first and last pitch values of the utterance but that they were consistent regardless of the length of utterance. However, the declination slope changed to be relatively gentle from the fourth accentual phrase to the end of the whole intonational phrase. There was a reset of declination in such a way that the first pitch in the second phrase was always lower than that of the first phrase, but the first pitch in the third phrase was not always lower than that of the second phrase when the whole utterance was composed of three phrases. Finally, the pitch values of the focusing words decreased as their position went back in a sentence. One declination line was formed in the case of focused utterance, but in the case of an utterance that contained a clause boundary, a new declination line was formed at the start of each new clause. These findings can be applied to developing a Korean speech synthesizer that contains natural prosody; they can be also utilized for teaching Korean prosody.

  • PDF

Signal Level Analysis of a Camera System for Satellite Application

  • Kong, Jong-Pil;Kim, Bo-Gwan
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2008년도 International Symposium on Remote Sensing
    • /
    • pp.220-223
    • /
    • 2008
  • A camera system for the satellite application performs the mission of observation by measuring radiated light energy from the target on the earth. As a development stage of the system, the signal level analysis by estimating the number of electron collected in a pixel of an applied CCD is a basic tool for the performance analysis like SNR as well as the data path design of focal plane electronic. In this paper, two methods are presented for the calculation of the number of electrons for signal level analysis. One method is a quantitative assessment based on the CCD characteristics and design parameters of optical module of the system itself in which optical module works for concentrating the light energy onto the focal plane where CCD is located to convert light energy into electrical signal. The other method compares the design\ parameters of the system such as quantum efficiency, focal length and the aperture size of the optics in comparison with existing camera system in orbit. By this way, relative count of electrons to the existing camera system is estimated. The number of electrons, as signal level of the camera system, calculated by described methods is used to design input circuits of AD converter for interfacing the image signal coming from the CCD module in the focal plane electronics. This number is also used for the analysis of the signal level of the CCD output which is critical parameter to design data path between CCD and A/D converter. The FPE(Focal Plane Electronics) designer should decide whether the dividing-circuit is necessary or not between them from the analysis. If it is necessary, the optimized dividing factor of the level should be implemented. This paper describes the analysis of the electron count of a camera system for a satellite application and then of the signal level for the interface design between CCD and A/D converter using two methods. One is a quantitative assessment based on the design parameters of the camera system, the other method compares the design parameters in comparison with those of the existing camera system in orbit for relative counting of the electrons and the signal level estimation. Chapter 2 describes the radiometry of the camera system of a satellite application to show equations for electron counting, Chapter 3 describes a camera system briefly to explain the data flow of imagery information from CCD and Chapter 4 explains the two methods for the analysis of the number of electrons and the signal level. Then conclusion is made in chapter 5.

  • PDF

광 결합 및 집속도 향상을 위한 금속 슬릿 프레넬 렌즈의 설계 (Design of Metal-Slit Fresnel Lens for Enhanced Coupling Efficiency)

  • 박동원;정영진;구석모;유선규;박남규;전영민;이석
    • 한국광학회지
    • /
    • 제20권1호
    • /
    • pp.1-5
    • /
    • 2009
  • 최근 광 격자구조나(photonic crystal) 표면 플라즈몬파(surface plasmon) 혹은 실리콘을 이용한 나노(nano) 스케일의 광 회로 시스템에 대한 연구가 활발한데, 이는 이미 한계에 다다른 전자회로속도의 한계를 극복하고 지금보다도 훨씬 작은 회로를 구성할 수 있는 이점이 있기 때문이다. 현재까지 보고된 바 있는 광 결합 시스템들은 그 크기가 나노 스케일의 광 회로 시스템에 비해 커서 광 결합 시스템으로서의 의미가 퇴색되고 있는데 본 논문에서는 매우 짧은 초점 거리를 가지며 매우 얇은 구조를 가지는 프레넬 렌즈를 이용한 광 결합 시스템을 제안하여 광 결합 시스템을 나노 스케일 광 회로 시스템과 비교할 수 있을 정도로 소형화 하는 방법을 모색하였다. 본 논문에서는 금 슬릿을 채용한 프레넬 렌즈를 제안하여 설계하고 그 구조를 이용해 2차원 전산모사를 수행하였다. 그 결과, 일반 프레넬 렌즈의 광 결합 효율이 약 43%인데 반해, 금 슬릿을 채용한 프레넬 렌즈의 광 결합 효율은 가장 효율적인 구조로 설계하였을 경우에 최대 약 65%의 광 결합 효율을 보인다. 일반 프레넬 렌즈에 비해 50% 이상의 광 결합 효율의 향상을 달성하였다.

카메라 렌즈 평가용으로 제작된 nodal slide식 실시간 OTF 측정 장치 (Real-time epical transfer function measuring system with on- and off-axis nodal slide bench type for evaluating the camera lens)

  • 이지영;송종섭;조재흥;장수;임천석;이윤우;이인원
    • 한국광학회지
    • /
    • 제13권2호
    • /
    • pp.92-97
    • /
    • 2002
  • 초측정 할 수 있는 nodal slide식 실시간 OTF 측정 장치를 제작하였다. 비축 물체를 측정하기 위하여 nodal slide와 T-bar를 사용하고, 실시간 측정을 위하여 화소 간격이 가로 9.9$\mu\textrm{m}$와 세로 9.6$\mu\textrm{m}$인 2차원 CCD(charge coupled device)를 사용하며, 초점 길이 300mm의 시준 렌즈를 사용하여 장치를 소형화하였다. 그리고 F/8, 초점 길이 50 mm인 SIRA사의 표준 렌즈를 이용하여 측정 장치의 정확도를 평가하고 보정하였다. 본 장치의 신뢰도를 위하여 시야각이 10.6$^{\circ}$이고, 초점 길이가 25.0mm인 CCTV & VIDEO 렌즈(JAPAN, AVENIR-SE 2514)의 MTF를 측정하여 카메라 벤취(bench)형 OTF측정 장치로부터 구한 MTF 값들과 상호 비교한 결과 대부분의 공간주파수에서 4% 이내로 일치하였다.

마주보는 대칭렌즈를 가지는 MWIR용 초점거리 24mm의 비구면 결상광학계 설계 (Design of Aspheric Imaging Optical System having 24mm Focal Length for MWIR with Facing Symmetric Lenses)

  • 이상길;김부태;이동희
    • 한국융합학회논문지
    • /
    • 제9권9호
    • /
    • pp.183-189
    • /
    • 2018
  • 본 연구는 마주보는 두 대칭렌즈를 가지는 초점거리 24mm 인 MWIR($3{\sim}5{\mu}m$)용 결상광학계의 설계 개발에 관한 것이다. 광학계는 CodeV를 사용하여 설계하였으며, 사용자의 요구조건을 만족할 수 있는 분해능과 화각을 가지도록 최적화 과정을 진행하였다. 렌즈의 초자는 국내에서 개발된 $3{\mu}m$에서 굴절률 1.7589를 갖는 초자( KCIR035 )를 포함하여 두 종류로 제한하였다. 이렇게 설계되어진 광학계는 같은 모양을 갖는 KCIR035 초자의 2장의 비구면 렌즈와 1장의 Si 초자의 구면 렌즈로 이루어져 있다. 여기서 2장의 비구면 렌즈의 배치는 마주보는 대칭구조를 이루고 있는 것이 특징이다. 그리고 이 광학계는 선폭 20lp/mm에서 MTF값이 0.35 이상인 분해능을 갖게 되었다. 따라서 이 광학계는 pixel의 크기가 $25{\mu}m$$206{\times}156$ 어레이 MWIR 검출소자를 사용하는 열영상 카메라에 적용할 수 있는 성능을 가진 것으로 판단된다.

LED 비디오월을 사용하는 방송환경에서 HD 카메라의 적정 초점거리 연구 (A Study on the Adequate HD Camera Focal Length in the Broadcasting Studio using LED Video Wall)

  • 최기창;권순철;이승현
    • 문화기술의 융합
    • /
    • 제8권5호
    • /
    • pp.713-721
    • /
    • 2022
  • LED 비디오월을 방송 현장에서 사용하기 위해서는 몇 가지 알아두어야 할 사항이 있다. 첫째, 픽셀이 촘촘히 배열되어 있기 때문에 짧은 배열 주기로 인한 무아레 현상이 나타날 수 있고, 둘째, 픽셀 간의 거리(픽셀피치)가 촬영하는 카메라 이미지 센서에 기록될 수 있다. 무아레 현상이 발생하거나 픽셀피치가 관찰되게 되면 시청자의 입장에서는 불편함을 느끼게 된다. 무아레 현상은 카메라의 촬영거리나 각도를 조정하면서 감소시킬 수 있지만, 픽셀피치가 이미지 센서에 녹화되는 걸 방지하기 위해서는 LED 비디오월과 카메라와의 거리를 충분히 확보하거나, 거리가 확보된 상태에서도 픽셀피치가 녹화되지 않도록 방송 현장에서 사용되는 줌렌즈의 배율을 적절하게 변화시켜 운용해야 한다. 원하는 화각을 얻기 위해 배율을 변경시켜 초점거리를 변동시키게 되면 의도치 않게 픽셀피치가 녹화되는 결과를 초래할 수 있다. 본 논문에서는 비디오월과의 거리가 충분히 확보된 상태에서 줌렌즈의 배율을 변경하면서 픽셀피치가 관찰되지 않는 범위에 대해 알아보았다. LED 비디오월에 영상을 재생시켜 B4 마운트 줌렌즈를 장착한 HD 카메라와 서버를 사용해 LED 비디오월 상태를 녹화하였고, TV 화면으로 재생하여 픽셀피치가 관찰되는지 확인해 보았다.

광섬유와 LED를 활용한 소형화된 검이경 개발 (Development of compact ear inspection probe with fiber-coupled LED)

  • 최영희;마혜준;이지성;최은서
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2009년도 동계학술발표회 논문집
    • /
    • pp.527-528
    • /
    • 2009
  • We developed the compact-sized ear inspector utilizing fiber-pigtailed cheap LED light source and CCD(charge coupled detector) camera. With adjusting the lens pair having different focal length respectively, optimized imaging conditions with fiber-coupled LED were obtained.

  • PDF