DOI QR코드

DOI QR Code

Real-time epical transfer function measuring system with on- and off-axis nodal slide bench type for evaluating the camera lens

카메라 렌즈 평가용으로 제작된 nodal slide식 실시간 OTF 측정 장치

  • Lee, Ji-Young (Applied Optics and Electromagnetics, School of Natural Sciences, Hannam University) ;
  • Song, Jong-Sup (Applied Optics and Electromagnetics, School of Natural Sciences, Hannam University) ;
  • Jo, jae-Heung (Applied Optics and Electromagnetics, School of Natural Sciences, Hannam University) ;
  • Chang, Soo (Applied Optics and Electromagnetics, School of Natural Sciences, Hannam University) ;
  • Rim, Cheon-Seog (Applied Optics and Electromagnetics, School of Natural Sciences, Hannam University) ;
  • Lee, Yun-Woo (Photometry and Imaging Optics, Korea Research Institute of Standards and Science) ;
  • lee, In-Won (Photometry and Imaging Optics, Korea Research Institute of Standards and Science)
  • 이지영 (한남대학교 자연과학부 광.전자물리학 전공) ;
  • 송종섭 (한남대학교 자연과학부 광.전자물리학 전공) ;
  • 조재흥 (한남대학교 자연과학부 광.전자물리학 전공) ;
  • 장수 (한남대학교 자연과학부 광.전자물리학 전공) ;
  • 임천석 (한남대학교 자연과학부 광.전자물리학 전공) ;
  • 이윤우 (한국표준과학연구원 광도.영상 그룹) ;
  • 이인원 (한국표준과학연구원 광도.영상 그룹)
  • Published : 2002.04.01

Abstract

A real-time OTF (optical transfer function) measuring system with on- and off-axis nodal slide bench type for the camera lens is fabricated and evaluated. It consists of a nodal slide bench including a T-bar for the OTF measurement of an off-axis object, two dimensional CCD (charge coupled device) with pixel of 9.9${\mu}{\textrm}{m}$$\times$9.6${\mu}{\textrm}{m}$ for real-time OTF measurment, and a collimating lens of focal length of 300 mm for the optimization of this system. The OTF system is corrected by using the OTF of a SIRA lens of fnumber of F/8 and focal length 50 mm. In order to confirm the reliability of the OTF system, two MTFs (modulus transfer functions) of CCTV & VIDEO lens (JAPAN, AVENIR-SE 2514) of focal length of 25mm and field of view 10.6$^{\circ}$are measured by the camera bench type OTF system of reference OTF system and the nodal slide bench type OTF system and compared with each other. As a result, these two values are agree well with each other within 4% from 0 1p/mm to 100 1p/mm.

초측정 할 수 있는 nodal slide식 실시간 OTF 측정 장치를 제작하였다. 비축 물체를 측정하기 위하여 nodal slide와 T-bar를 사용하고, 실시간 측정을 위하여 화소 간격이 가로 9.9$\mu\textrm{m}$와 세로 9.6$\mu\textrm{m}$인 2차원 CCD(charge coupled device)를 사용하며, 초점 길이 300mm의 시준 렌즈를 사용하여 장치를 소형화하였다. 그리고 F/8, 초점 길이 50 mm인 SIRA사의 표준 렌즈를 이용하여 측정 장치의 정확도를 평가하고 보정하였다. 본 장치의 신뢰도를 위하여 시야각이 10.6$^{\circ}$이고, 초점 길이가 25.0mm인 CCTV & VIDEO 렌즈(JAPAN, AVENIR-SE 2514)의 MTF를 측정하여 카메라 벤취(bench)형 OTF측정 장치로부터 구한 MTF 값들과 상호 비교한 결과 대부분의 공간주파수에서 4% 이내로 일치하였다.

Keywords

References

  1. KRASS-98-104-MO 한국표준과학연구원
  2. Applied Optics v.30 N. F. Borrelli;R. H. Bellman;J. A. Durbin;W. Lama https://doi.org/10.1364/AO.30.003633
  3. 한국광학회지 v.2 no.3 비축상 OTF의 정밀측정 조현모;이윤우;이회윤;이인원
  4. Introduction to Fourier Optics J. W. Goodman
  5. 波動光學 이상수
  6. Optical Shop Testing D. Malacara
  7. The Optical Transfer Function of Imaging System T. L. Williams