• Title/Summary/Keyword: Focal

Search Result 2,377, Processing Time 0.028 seconds

Improving the Sensitivity of an Ultraviolet Optical Sensor Based on a Fiber Bragg Grating by Coating With a Photoresponsive Material (광반응 재료가 코팅된 단주기 광섬유격자 기반 자외선센서의 광민감도 향상 연구)

  • Kim, Woo Young;Kim, Chan-Young;Kim, Hyun-Kyoung;Ahn, Tae-Jung
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.2
    • /
    • pp.83-87
    • /
    • 2015
  • This study was focused on developing an optical sensor that monitors ultraviolet (UV) light. Recently, we proposed and demonstrated a novel, highly sensitive UV sensor based on a fiber Bragg grating (FBG). To ensure that the incident UV light is focused on the FBG surface, the sensor was coated with an azobenzene polymer material that acts as a UV-induced stretchable functional material, in combination with a cylindrical focal lens. In this study we have improved the sensitivity of the sensor by employing a cylindrical focal mirror as a curved reflector, to refocus the UV light passing through the FBG. We considered the performance of several different types of reflectors and chose the optimal radius of curvature for the reflector. Compared to the UV sensor without an auxiliary device, the sensitivity of the FBG sensor with a focal lens and a curved reflector was 15 times as high.

Effects of Simultaneous Application of Focal Vibration Stimulation and Task-Oriented Training in the Improvement of Upper Extremity Motor Function after Stroke (국소 진동자극과 과제 지향적 훈련의 동시 적용이 뇌졸중 환자의 상지 기능 개선에 미치는 효과)

  • Kim, Sunho
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.3
    • /
    • pp.117-125
    • /
    • 2019
  • Purpose : The purpose of this study was to determine the effects of simultaneous application of focal vibration stimulation and task-oriented training on the improvement in upper extremity motor function after stroke. Methods : The study period was from January to April 2019; 23 patients who fulfilled the study eligibility criteria were enrolled. The participants were divided into two groups: the experimental group with vibration stimulation and task-oriented training and the control group with only task-oriented training. Training was conducted in a total of 20 sessions, 5 times a week for 30 minutes a day for 4 weeks. The amount of use of the affected and unaffected side by accelerometers, and Box and Block test (BBT), Action Research Arm Test (ARAT) was measured with a pre-test, a post-test. Wilcoxon Signed Rank Test and Analysis of Covariance were used to compare and analyze the changes within and between the groups. Results : Both the groups showed statistically significant changes in the results of the BBT and the ARAT, as well as the amount of use of the affected and unaffected side. Regarding the use of the affected side, BBT results, and the grasp and gross movement item of the ARAT showed significant changes in the experimental group compared with the control group. Conclusion : We found that simultaneous application of focal vibration stimulation and task-oriented training was more effective than task-oriented training alone. A large-scale comparative study involving a group that is only given vibration stimulation should be conducted for more generalizable results.

Quality Evaluation of Ultrasonographic Equipment Using an ATS-539 Multipurpose Phantom in Veterinary Medicine

  • Cho, Young-kwon;Lee, Youngjin;Lee, Kichang
    • Journal of Veterinary Clinics
    • /
    • v.39 no.3
    • /
    • pp.114-120
    • /
    • 2022
  • The purpose of this study is to examine the status of quality control using multipurpose phantom of ultrasound equipment used in hospital of veterinary college in South Korea by using ATS-539 multipurpose phantom so as to examine quantitative and objective new image evaluation method. Specialists discussed and analyzed multipurpose phantom images acquired by using convex transducer of 10 ultrasound imaging devices, currently used in 9 veterinary colleges, at 4.0-6.0 MHz. Total 8 items that can be measured with ATS-539 multipurpose phantom including dead zone, vertical and horizontal measurement, axial/lateral resolution, sensitivity, focal zone, functional resolution and gray scale/dynamic range were evaluated. For qualitative evaluation, valid decisions were made based on dead zone, axial/lateral resolution, and gray scale/dynamic range which are resolution index, and coefficient of variation (COV) and blind referenceless image spatial quality evaluator (BRISQUE) were found to increase objectivity. As a result of experiment, all the targeted ultrasonic devices were found appropriate from qualitative evaluation items of dead zone, axial/lateral resolution, and gray scale/dynamic range. In other evaluation items, they were found to be appropriate from focal zone and vertical measurement of quantitative evaluation while inappropriate from horizontal measurement, sensitivity, and functional resolution. COV value was 0.12 ± 0.04, and BRISQUE value was 47.77 ± 2.77, both analysis results show that the noise level of all ultrasonic devices was located within tolerance range. Upon image examination using ATS-539 multipurpose phantom, they were 100% appropriate with inspection standards of dead zone, axial/lateral resolution, and gray scale/dynamic range, and besides, focal zone and functional resolution can be used as evaluation items. In the field of veterinary medicine, 8 standard items using ATS-539 multipurpose phantom and image evaluation items using COV and BRISQUE can be used as standards for quality control of ultrasonography machine.

Arterial Wall Imaging in Angiographically Occult Spontaneous Subarachnoid Hemorrhage : New Insight into the Usual Suspect

  • Yoon, Wonki;Kim, Jang Hun;Roh, Haewon;Kwon, Taek-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.2
    • /
    • pp.245-254
    • /
    • 2022
  • Objective : The etiology of angiographically occult spontaneous subarachnoid hemorrhage (AOsSAH) is unclear. Three-dimensional (3D) high-resolution vessel wall magnetic resonance imaging (HVM) might be useful in detecting the hidden arterial wall angiopathy in patients with AOsSAH. We aimed to demonstrate the feasibility of HVM for detecting the arterial cause of AOsSAH. Methods : Patients, who were diagnosed with AOsSAH in the first evaluations and underwent HVM, were enrolled. Their clinical and radiologic data were retrospectively reviewed. Especially, focal enhancement of arterial wall on HVM and repetitive catheterized angiograms were precisely compared. Results : Among 251 patients with spontaneous SAH, 22 patients were diagnosed with AOsSAH in the first evaluations (8.76%). After excluding three patients who did not undergo 3D-HVM, 19 patients were enrolled and classified as convexal (n=2) or perimesencephalic (n=4), and diffuse (n=13) groups. In convexal and perimesencephalic groups, no focal enhancement on HVM and no positive findings on repetitive angiography were noted. In diffuse group, 10 patients showed focal enhancement of arterial wall on HVM (10/13, 76.9%). Repeated angiography with 3D reconstruction revealed four patients of angiographically positive causative arteriopathy and possible lesion in one case in the concordant location of intramural enhancement on 3D-HVM (5/10, 50%). Three of them were treated with endovascular stent insertion. All patients, except one, recovered with good clinical outcome (3-month modified Rankin score, 0 and 1). Conclusion : 3D-HVM was useful in detecting hidden true arteriopathy in AOsSAH. It may provide new insights into the etiologic investigation of AOsSAH by proving information about the arterial wall status.

Enhanced Lung Cancer Segmentation with Deep Supervision and Hybrid Lesion Focal Loss in Chest CT Images (흉부 CT 영상에서 심층 감독 및 하이브리드 병변 초점 손실 함수를 활용한 폐암 분할 개선)

  • Min Jin Lee;Yoon-Seon Oh;Helen Hong
    • Journal of the Korea Computer Graphics Society
    • /
    • v.30 no.1
    • /
    • pp.11-17
    • /
    • 2024
  • Lung cancer segmentation in chest CT images is challenging due to the varying sizes of tumors and the presence of surrounding structures with similar intensity values. To address these issues, we propose a lung cancer segmentation network that incorporates deep supervision and utilizes UNet3+ as the backbone. Additionally, we propose a hybrid lesion focal loss function comprising three components: pixel-based, region-based, and shape-based, which allows us to focus on the smaller tumor regions relative to the background and consider shape information for handling ambiguous boundaries. We validate our proposed method through comparative experiments with UNet and UNet3+ and demonstrate that our proposed method achieves superior performance in terms of Dice Similarity Coefficient (DSC) for tumors of all sizes.

F_MixBERT: Sentiment Analysis Model using Focal Loss for Imbalanced E-commerce Reviews

  • Fengqian Pang;Xi Chen;Letong Li;Xin Xu;Zhiqiang Xing
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.18 no.2
    • /
    • pp.263-283
    • /
    • 2024
  • Users' comments after online shopping are critical to product reputation and business improvement. These comments, sometimes known as e-commerce reviews, influence other customers' purchasing decisions. To confront large amounts of e-commerce reviews, automatic analysis based on machine learning and deep learning draws more and more attention. A core task therein is sentiment analysis. However, the e-commerce reviews exhibit the following characteristics: (1) inconsistency between comment content and the star rating; (2) a large number of unlabeled data, i.e., comments without a star rating, and (3) the data imbalance caused by the sparse negative comments. This paper employs Bidirectional Encoder Representation from Transformers (BERT), one of the best natural language processing models, as the base model. According to the above data characteristics, we propose the F_MixBERT framework, to more effectively use inconsistently low-quality and unlabeled data and resolve the problem of data imbalance. In the framework, the proposed MixBERT incorporates the MixMatch approach into BERT's high-dimensional vectors to train the unlabeled and low-quality data with generated pseudo labels. Meanwhile, data imbalance is resolved by Focal loss, which penalizes the contribution of large-scale data and easily-identifiable data to total loss. Comparative experiments demonstrate that the proposed framework outperforms BERT and MixBERT for sentiment analysis of e-commerce comments.

A Study on the Intensity and Energy Attenuation of the 13 December 1996 Yeongweol Earthquake, Korea (1996년 12월 13일 영월 지진의 진도 및 에너지감쇠에 관한 연구)

  • 조봉곤;김성균;김우한;김준경;박창업
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.69-77
    • /
    • 1997
  • An intensity survey on the 13 December 1996 Yeogweol earthquake has mode for 262 locations throughout southern part of Korean peninsula, then we investigated attenuation properties in the south Korean region as well as intensities distribution. In this study, intensities are estimated to be from II to possibly VIII. The iso-seismal intensity map we obtained shows general pattern of intensity distribution in the south korean region quite clearly despite the inherent uncertainties included in the process of intensity estimation. In case of intensity larger than VI, considerable damages such as fracturing walls are frequently reported. One of the significant feature of this intensity map is, considering its magnitude 4.5 reported by KMA, the felt area is unusually large covering most of the Korean Peninsular except Cheju island. This result indicates either the magnitude is under estimated or the focal depth is much deeper than expected. Assuming indicates either the magnitude is under estimated or the focal depth is much deeper than expected. Assuming shallow earthquake whose focal depth is by iso-seismal contour lines for intensity IV to VII, respectively. To resolve this ambiguity, more reliable estimation of focal depth and magnitude by using telesesmic instrumental records should be made in the future.

  • PDF

Integral Imaging System Enabling Enhanced Depth of Field Incorporating a Birefringent Liquid Crystal Lens Array (복굴절 특성을 갖는 액정 렌즈어레이를 이용한 깊이감이 향상된 집적영상 시스템)

  • Park, Chan-Kyu;Hwang, Yong-Seok;Lee, Sang-Shin
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.6
    • /
    • pp.394-399
    • /
    • 2008
  • An integral imaging system enabling enhanced depth of field by incorporating a pair of liquid-crystal (LC) lens arrays was proposed and demonstrated. The lens arrays exhibit two different refractive indexes depending on the light polarization. The proposed LC lens array I and II were implemented by depositing a ZLI-4119 LC and an E-7 LC, respectively, on top of a lens-array substrate in glass. When the two LC lens arrays were aligned appropriately, a birefringence was obtained for a specific light polarization in such a way that the incoming light sees different refractive indexes for them. As a result, the focal length associated with the imaging system utilizing the LC lens arrays was adaptively varied, thereby enhancing the depth of field for the image reconstruction. We have theoretically analyzed the proposed integral imaging system with the $LightTools^{(R)}$ to confirm that the focal length could be adjusted with the help of the birefringent lens array. Finally the proposed imaging system successfully reconstructed the objects. The birefringent lens array employing the ZLI-4119 LC produced a real image with the focal length of 680 mm, while the other using the E-7 LC yielded a virtual image with the focal length of -29 mm.

The Effects of Swim Training on Neurogenesis in the Hippocampal Dentate Gyrus and Functional Ability After Focal Ischemic Stroke in Rats (수영 훈련이 뇌허혈 유발 흰쥐의 해마 치아이랑에서 뇌신경생성과 기능적 능력에 미치는 영향)

  • Kim, Ho-Sung;Kim, Deuk-Ho;Lee, Jeong-Pil;Kim, Young-Joo;Shin, Young-Oh;Kim, Sang-Hoon;Kwon, Ki-Wook;Oh, Jae-Keun
    • Physical Therapy Korea
    • /
    • v.12 no.3
    • /
    • pp.11-21
    • /
    • 2005
  • The present study was aimed at investigating the effect of swimming training on brain function after focal cerebral ischemia in rats. Therefore, this study was examined on neurogenesis in dentate gyrus of hippocampus using 5-bromo-2'-deoxyuridine (BrdU) to label proliferating cells and assessed the neurological response following focal cerebral ischemia in rats using neurological motor behavioral test. In an observer-blinded fashion, twenty male Sprague-Dawley (280~310 g, 7 weeks old) rats were divided into four groups: MCAO plus swimming group (ME, $n_1$=5), MCAO plus control group (MC, $n_2$=5), SHAM plus swimming group (SE, $n_3$=5), SHAM plus control group (SC, $n_4$=5). The results of this study were as follows: 1) The limb placing time before and after swimming in the ME group were significantly longer than the MC group (p<.05), the SE group were significantly longer than the SC group (p<.01). 2) The balance beam scores before and after swimming in the ME group was higher than the SE group, the MC group was higher than the SC group but was not significantly different (p>.001). 3) The foot fault index before and after swimming training in ME group was significantly lower (i.e., improved) than the MC group (p<.001) and the SE group (p<.001), the SE group was significantly lower (i.e., improved) than the SC group (p<.001). 4) The mean number of BrdU-positive cells in the dentate gyrus in the ME group was significantly higher than the MC group (p<.001) and the SE group (p<.01). The MC group and the SE group was significantly higher than the SC group (p<.001). 5) There was significantly correlation between limb placing time and number of BrdU-positive cells on swimming training, there was positive correlation (r=.807, p<.0001) and between foot fault index and BrdU-positive cells number, there was negative correlation (r=-.503, p<.05). However, between balance beam scores and BrdU-positive cells number, there was no correlation. In conclusion, the present study demonstrates that the role of swimming training improves behavioral motor function probably by enhancing cell proliferation in that hippocampus. This study provides a model for investigating the stroke rehabilitation that underlies neurogenesis and functional ability.

  • PDF

Improved Focal Liver Lesion Detection by Increasing Flip Angle During Gadoxetic Acid-Enhancement in MRI (Gadoxetic acid 조영증강 자기공명영상에서 숙임각 변화에 따른 국소 간종양 검출능 비교)

  • Lee, SeJy;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.115-120
    • /
    • 2015
  • To study the differences of focal liver lesion image detection at 3 minute, 10 minute and 15 minute time points on gadoxetic acid (GA)'s enhanced MR imaging with a flip angle (FA) of $30^{\circ}$ compared with a $11^{\circ}$. The subjects were 69 patients evaluated with GA enhanced MR imaging with 3.0T MR scanner. The patients are total 35(23 men and 7 women at the mean age of 60.4 years), hepatocellular carcinoma(23) and metastsis(12) except for normal, cyst and hemangioma. After GA was injected, FA $11^{\circ}$ and $30^{\circ}$ images were obtained at 3 minute, 10 minute and 15 minute time points respectively. After quantitative and qualitative assessment of each image was done, statistical analysis was performed by using the independent sample T-test. From both quantitative and qualitative assessment of 3 minute and 10 minute MR images after the injection of GA, FA $30^{\circ}$ images was found to be superior than FA $11^{\circ}$, but there were no statistical significance. However, at 15 minute time point, Statistically significant FA $30^{\circ}$ image(p<0.05) was better than FA $11^{\circ}$ therefore, the FA $30^{\circ}$ improves the focal liver lesion detection. FA $30^{\circ}$ of MR image can detect liver lesion more sensitively than the existing $FA11^{\circ}$ image after GA contrast enhancement at 15 minute time point.