• Title/Summary/Keyword: Focal

Search Result 2,377, Processing Time 0.027 seconds

Optics for Satellite Remote Sensing Systems

  • Opt
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1995.06a
    • /
    • pp.53-58
    • /
    • 1995
  • Examples of advanced digital electro-optic imaging systems for the satellite remote sensing applications are introduced including multispectral focal plane assembly for newly proposed 1-m spatial resolution capability.

  • PDF

Range finding algorithm of equidistance stereo catadioptric mirror (등거리 스테레오 전방위 렌즈 영상에 대한 위치 측정 알고리즘)

  • Choi, Young-Ho
    • Journal of Internet Computing and Services
    • /
    • v.6 no.6
    • /
    • pp.149-161
    • /
    • 2005
  • Catadioptric mirrors are widely used in automatic surveillance system. The major drawback of catadioptric mirror is its unequal image resolution. Equidistance catadioptric mirror can be the solution to this problem. Even double panoramic structure can generate stereo images with single camera system. So two images obtained from double panoramic equidistance catadioptric mirror can be used in finding the depth and height values of object's points. But compared to the single catadioptric mirror. the image size of double panoramic system is relatively small. This leads to the severe accuracy problem in estimation. The exact axial alignment and the exact mount of mirror are the sources that can be avoided but the focal length variation is inevitable. In this paper, the effects of focal length variation on the computation of depth and height of object' point are explained and the effective focal length finding algorithm, using the assumption that the object's viewing angles are almost same in stereo images, is presented.

  • PDF

Compact Anode Design with the Heat Capacity Performance in Rotating Anode X-ray Tube for Digital Radiography

  • Lee, Seok Moon
    • Applied Science and Convergence Technology
    • /
    • v.24 no.5
    • /
    • pp.136-141
    • /
    • 2015
  • We studied the compact anode design to develop 100 kW rotating anode X-ray tube with large focal spot 1.2 mm, small focal spot 0.6 mm and tube voltage 150 kV for large hospital digital radiography using computer thermal simulation. The larger thermal radiation effect in a high vacuum can reduce the temperature of anode so the method to increase the surface area of anode is investigated. The anode has the multi-tier shape at the back side of TZM body of anode and also bigger diameter of anode. The number of multi-tiers was varied from 6 to 15 and the diameter of anode was also varied from ${\Phi}74$ to ${\Phi}82$. From ANSYS transient thermal simulation result, we could obtain $1056.4^{\circ}C$ anode maximum temperature when applying 100 kW input power at 0.1 second on target focal track which is less than $1091^{\circ}C$ of the conventional 75 kW X-ray tube with reduced anode weight by 15.5% than the conventional anode. The compact anode of reduced anode weight is able to improve the unwanted noise when the rotor is rotating at high-speed and also reduce the rotational torque which the cost effective stator-coil is possible. It is believed that the anode with 15 ea multi-tiers using ${\Phi}82$ can satisfy with the specification of the anode heat capacity. From the results of this paper, it has been confirmed that the proposed compact anode can be used as the anode of 100 kW rotating anode X-ray tube for digital radiography.

Source parameters for the December 13 1996 ML 4.5 Earthquake in Yeongwol, South Korea (1996년 12월 13일 ML 4.5 영월 지진의 지진원 상수)

  • Choi, Ho-Seon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.23-29
    • /
    • 2009
  • On December 13, 1996, an earthquake with local magnitude (M$_L$) 4.5 occurred in the Yeongwol area of South Korea. The epicenter was 37.2545$^{\circ}$N and 128.7277$^{\circ}$E, which is located inside the Okcheon Fold Belt. The waveform inversion analysis was carried out to estimate source parameters of the event according to the filtering bandwidth of seismic data. Using 0.02$\sim$0.2 Hz filtering bandwidth, focal depth and seismic moment were estimated to be 6 km and 1.3$\times$10$^{16}$ N$\cdot$m, respectively. This seismic moment corresponds to the moment magnitude (M$_W$) 4.7. The focal mechanism by the waveform inversion and P wave first motion polarity analysis is a strike slip faulting including a small thrust component, and the direction of P-axis is ENE-WSW. The moment magnitude estimated by spectral analysis was 4.8, which is similar to that estimated by waveform inversion. Average stress drop was estimated to be 14.3 MPa.

Tibia Vara Caused by Focal Fibrocartilaginous Dysplasia(FFCD) - Case Report - (국소적 섬유연골성 이형성증(FFCD)에 의한 경골 내반 - 증례 보고 -)

  • Lee, Sang-Soo;Hwang, Ho-Yeun;Lee, Dong-Hee;Nam, Il-Hyun;Paik, Ae-Lan;Sohn, Kyung-Rak;Lee, Sang-Un
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.6 no.2
    • /
    • pp.106-111
    • /
    • 2000
  • Focal fibrocartilaginous dysplasia(FFCD) is an uncommon, benign condition associated with unilateral tibia vara among young children. FFCD has a typical plain radiographic finding, which has a concave radiolucent defect in the metadiaphyseal junction of medial aspect of the proximal tibia. The varus deformity occurs at the site of the lesion. Spontaneous remodeling and resolution of bony defect may be expected, but the corrective osteotomy may also be needed in some cases. The authors described a case of unilateral tibia vara caused by FFCD, diagnosed by excisional biopsy and treated with dome-shaped proximal tibial osteotomy and bone graft.

  • PDF

Analysis on the Validity of 'Point of Knowing' in Elementary Mathematics Textbook (초등학교 수학 교과서에 나타나는 앎의 시점의 타당성 분석)

  • Kang, Taeseok;Kang, Wan;Lim, Dawon
    • Journal of Educational Research in Mathematics
    • /
    • v.26 no.4
    • /
    • pp.731-754
    • /
    • 2016
  • The purpose of the study is to identify the point of knowing. The point of knowing is the time, which indicates that 'knowing' occurs in the recognition process. To understand recognition process, the researchers analyzed the questions in units of lessons presented in elementary mathematics textbooks. The researchers analyzed the validity of the point of knowing and found out the basis of the point of knowing. The results are as follows. First, the point of knowing is time to expect to change from a leaner's 'not-knowing' to 'knowing'. Second, the point of knowing can be identified with the questions on textbooks to ask students to do practical action. Third, the point of knowing is closely related to instructional objective in a class. Fourth, in relation to subsidiary awareness and focal awareness, the point of knowing corresponds to focal awareness. Fifth, the point of knowing is equivalent to the inflection point at which personalization/contextualization is changed into depersonalization/decontextualization.

Anti-apoptotic and Neuroprotective Effects of Bambusae Caulis in Liquamen Manufactured by Different Production Process (생산공정 차이에 따른 죽력(竹瀝)이 apoptosis 및 신경세포 보호 효과에 미치는 영향)

  • Choi, Chan-Hun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.5
    • /
    • pp.1250-1259
    • /
    • 2007
  • Bambusae Caulis in Liquamen(BCL) has been commonly prescribed for stroke patients in the traditional Oriental medicine. So this study is aims to investigate the anti-apoptotic and neuroprotective effects of Bambusae Caulis in Liquamen(BCL) manufactured by different production process on the focal ischemia induced by intraluminal filament insertion in rats. The focal ischemia was induced by intraluminal filament insertion into middle cerebral artery. The animals were divided into four groups (n=15 in each group). The ischemia induced and not treated group : Control group, the ischemia induced and oral medication of the three kinds of BCL : BCL-A group, BCL-B group, BCL-C group. BCL-A was produced by heating at a low temperature$(250^{\circ} C)$ in electric kiln and filtering. BCL-B was produced by heating at a high temperature$(900^{\circ} C{\sim}1,000^{\circ}C)$ in yellow earth kiln and refining and filtering. BCL-C was produced by heating at a low temperature$(400^{\circ} C)$ yellow earth kiln and no refining and filtering. The anti-apoptotic and neuroprotective effects of the oral medication of BCL were observed by Bax, BCL-2, cytochrome c, mGluR5, cresyl violet and ChAT-stain. Our study suggests that BCl-A(was produced by heating at a low temperature in electric kiln and filtering) and BCL-C(was produced by heating at a low temperature in yellow earth kiln and no refining and filtering) show anti-apoptotic and neuroprotective effects on the focal ischemia induced by intraluminal filament insertion in rats and BCL-C is more effective than BCL-A.

Automatic Depth-of-Field Control for Stereoscopic Visualization (입체영상 가시화를 위한 자동 피사계 심도 조절기법)

  • Kang, Dong-Soo;Kim, Yang-Wook;Park, Jun;Shin, Byeong-Seok
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.4
    • /
    • pp.502-511
    • /
    • 2009
  • In order to simulate a depth-of-field effect in real world, there have been several researches in computer graphics field. It can represent an out-of-focused scene by calculating focal plane. When a point in a 3D coordinate lies on further or nearer than focal plane, the point is presented as a blurred circle on image plane according to the characteristic of the aperture and the lens. We can generate a realistic image by simulating the effect because it provides an out-of-focused scene like human eye dose. In this paper, we propose a method to calculate a disparity value of a viewer using a customized stereoscopic eye-tracking system and a GPU-based depth-of-field control method. They enable us to generate more realistic images reducing side effects such as dizziness. Since stereoscopic imaging system compels the users to fix their focal position, they usually feel discomfort during watching the stereoscopic images. The proposed method can reduce the side effect of stereoscopic display system and generate more immersive images.

  • PDF

Clinical Outcomes according to Radiological Classification of Brainstem Hemorrhages (방사선학적 출혈양상에 근거한 뇌간출혈의 분류에 따른 임상결과)

  • Cho, Won Jung;Moon, Seong Ho;Lee, Seung Min;Yang, Jae Young;Choi, Chun Sik;Ju, Mun Bae
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.2
    • /
    • pp.217-221
    • /
    • 2000
  • Objective : Brainstem hemorrhages usually result in much higher mortality and morbidty than any other intracranial vascular lesions. The purpose of the study is to evaluate the relationship of the radiological classification of the lesions and the clinical outcomes, and to evaluate the value of such classification on the choice of management modality. Method : Thirty seven patients with primary brainstem hemorrhage were managed medically or surgically between Oct. 1995 and Mar. 1998. The lesions were classified as two groups based on radiological findings as follows : Focal subependymal hematoma(group I, n=7) and diffuse tegmentobasilar hemorrhage(group II, n=30). The outcomes at discharge were retrospectively reviewed according to such classification. Result : The most common clinical pictures and radiological findings in each group were as followings : 1) Group I : focal compressive lesion which displaces rather than destroys brain tissue. It occurs in a younger age group and causes neurological deficits which are often partially reversible. Operative hematoma evacuation was performed in 43.3%. Their mean improved Glasgow Coma Scale(GCS) score was 4.7. 2) Group II : hypertensive brain stem hemorrhage. It usually causes a diffuse lesion occurring in an older age group and most often associated with profound irreversible neurological deficits which are often fatal. Operative hematoma evacuation was performed in 16.7%. Their mean improved GCS score was 1.4. In both conservatively treated group I and II has no siginificant clinical improvement. Conclusion : Although there is an overlap among them and the size of the group is small, the pathophysiologic classification of this lesion based on clinical features and radiological findings may be useful for decision of treatment method.

  • PDF