• Title/Summary/Keyword: Focal

Search Result 2,377, Processing Time 0.028 seconds

Parametric Analysis of Digital Particle Holography for Spray Droplets (분무 액적을 위한 디지털 입자 홀로그래피의 파라미터 해석)

  • Yang, Yan;Kang, Bo-Seon
    • Journal of ILASS-Korea
    • /
    • v.12 no.4
    • /
    • pp.191-197
    • /
    • 2007
  • This study presents in-line digital particle holography and its application to spray droplets to measure the characteristics of spray droplets. Several important parameters at the time of hologram recording such as the object distance and the region of laser beam used were verified. The correlation coefficient method with important parameters such as the reconstruction interval and the correlation interval was used for determination of the focal planes of particles. The optimal values of all these parameters are obtained by either numerical simulation of holograms or experiments. Using these optimal parameters, double pulse digital spray holograms in a short time interval were recorded with the synchronization system for the time control. The spatial positions of droplets that are used for the evaluation of the three dimensional droplet velocities can be easily located, which proves the feasibility of the digital holographic technology for measurements of several important features of spray droplets.

  • PDF

Spatial Characterization of MAC, a High-Resolution Optical Earth Observation Camera for Small Satellites

  • Kim Eugene D.;Choi Young-Wan;Yang Ho-Soon;Ismail Mohd. Afiq bin
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.79-83
    • /
    • 2005
  • Spatial calibrations have been performed on the Medium-sized Aperture Camera (MAC) of the RazakSAT satellite. Topics discussed in this paper include the measurements of system modulation transfer function (MTF), relative pixel line-of-sight (LOS), and end-to-end imaging tests. The MTF measurements were made by capturing the scanned knife-edge image on a pixel, and an issue in the MTF calculation algorithm is discussed. The method used to place the focal plane at the correct focal position is described, since they make use of MTF measurements. Relative LOS measurements are done by theodolite measurements of the telescope. Qualitative ground test result of end-to-end imaging is given.

Liquid Immersion Method for Determining the Refractive Index of a Lens by using the Murty Shearing Interferometer (층밀리기 간섭계를 이용한 렌즈 굴절률의 비파괴적 측정)

  • 이윤우;조현모;이인원
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.1
    • /
    • pp.7-12
    • /
    • 1991
  • A nondestructive technique for measuring the refractive index of a simple lens is described. The shearing interferornetric technique is used for determining the focal length of a lens by immersing it in various liquids. The lens itself acts as autocollimator and decollimator. An equation for the defocusing error has been theoretically deduced and experimentally verified. The wave aberration has also been investigated for the different values of the focal length.

  • PDF

A Study on Energy Distributions Produced by Dish Solar Concentrating System (접시형 태양열 집광 시스템의 에너지 분포 특성에 관한 연구)

  • 현성택;강용혁;천원기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.907-913
    • /
    • 2002
  • An experimental study on energy density distributions produced by dish solar concentrating system was performed to optimally design and rightly position a cavity receiver. This deemed also very useful to find and correct various errors associated with a concentrator. It is observed that the actual focal length is 2.17 m with a maximum energy density of 1.89 MW/$m^2$. By evaluating the position of flux centroid, it was found that there are errors within 2 cm from the target center. As a result of the percent power within radius, approximately 90% of the incident radiation is intercepted by about 0.06 m radius. The area concentration ratio normalized to 800 W/$m^2$ insolation and 90% mirror reflectivity was 347 suns. The total integrated power of 2467 W was measured under focal flux distributions, which corresponds to the intercept rate of 85.8%.

A study for Earthquake Parameter of Ulgin Earthquake (울진지진(2004/05/29)의 지진원상수에 관한 연구)

  • Yoo, Seong-Hwa;Kim, Jun-Kyoung;Oh, Tea-Suk
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.69-74
    • /
    • 2007
  • The source mechanism parameters of the Ulgin earthquake on 29 May 2004 are analyser using moment tensor inversion technique. The Green's function are calculated for the Kim's(1985) crust model of southern Korean Peninsula. Results derived from the Ulgin earthquake show the dependence of azimuthal station distribution and epicentral distances. final results show fairly good agreement to those of other authors. the focal mechanism for the Ulgin earthquake is found to be oblique reverse motion with NNE strike. The focal depth is estimated to be 10-12km.

  • PDF

x$^{(3)}$ Measurement through Self-focusing with Non-gaussian Beam (비 Gaussian 빛에 의한 자체집광을 이용한 x$^{(3)}$측정)

  • 이범구
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.428-433
    • /
    • 1993
  • The second harmonic of Q-switched Nd:YAG laser beam with gaussian mode is cut off by pinhole of a certain radius and its central portion passed through pinhole is focused by converging lens. It is confirmed that the shape of this beam in focal region is central symmetric but non-gaussian. Change of transmittance due to self-focusing is investigated by scanning (z-scan) $CS_2$ of 1 mm thickness in the focal region. It is found that the observed results can be consistently explained by Fresnel theory within 1.5% accuracy and efficiency of self-focusing depends on spatial shape of incident beam.

  • PDF

Mn-DPDP enhanced MR imaging in Detection of Focal Hepatic lesion: Evaluation of the Efficacy & Optimization of Pulse Sequence (국소간의 자기공명영상에서 Mn-DPDP의 유용성과 적합한 MR Sequence에 관한 비교, 고찰)

  • Kim Eun Seong;Kim Dae Hyeon;Lee Hyeon Geun;O Geun Taek;Lee Sun No;Lee U Sik
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.104-114
    • /
    • 2001
  • Ⅰ. Purpose : To evaluate the diagnostic value of Mn-DPDP for the detection of focal hepatic lesions on MR images and to determine the optimal pulse sequence to maximize its effect. Ⅱ. Material and Methods : Twenty-eight patients(6 women and 22 men, aged f

  • PDF

A Method for Measurement of Limiting Intrinsic Non-Uniformity Due to Process in CCD-Multiplexers for Focal Plane Arrays

  • Bhan, R.K.;Saxena, R.S.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.2 no.1
    • /
    • pp.87-92
    • /
    • 2002
  • We present a simple experimental method for determination of limiting intrinsic fixed-pattern non-uniformity (NU) due to fabrication process in two-dimensional CCD multiplexers (MUXs) that are used for hybrid focal plane arrays. Here, this is done by determining separately the two NUs viz. that are $V_T$ dependent and $V_T$ independent. From these measurements, process dependent NU can be extracted. It is argued that $V_T$ dependent NU can be eliminated by designing novel input circuits whereas $V_T$ independent NU, primarily, dependent on process control and material variations may be reduced but cannot be eliminated completely and hence limits the FPA performance eventually.

Abattoir survey of kidney lesions in Korean cattle (도축한우의 신장에 대한 병리학적 연구)

  • 노영선;윤여백;김영진;이성희;레브코로지스키;임병무;임채웅
    • Korean Journal of Veterinary Service
    • /
    • v.24 no.2
    • /
    • pp.139-146
    • /
    • 2001
  • To examine the prevalence and types of kidney lesions in Korean cattle, a survey was carried out at a abattoir in september 2000 and January 2001. The collected kidneys were examined grossly and histopathologically and investigated for the patterns of renal diseases with considering season and sex. Of 735 cattle (99 bulls and 246 cows in September and 140 bulls, 3 steers, and 247 cows in January) surveyed, 301 (41%) cattle had various renal lesions. The most common prominent finding was focal or multiple interstitial nephritis (36.2%). Other lesions included focal or multiple renal cyst (9.1%), infarction (0.1%), hemorrhage (0.3%), and renal atrophy (0.3%). Microscopically, main pathological lesions were acute or chronic interstitial nephritis with moderate infiltration of neutrophil or lymphocyte, respectively. Finally, the kidney lesions are more or less correlated with the meat quality, especially in female Korean cattle.

  • PDF

An Improved Reticle Seeker Using the Segmented Forcal Plane Array (segmented Focal Plane Array를 이용한 개선된 레티클 탐색기)

  • 홍현기;한성현;최종수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.10
    • /
    • pp.2670-2678
    • /
    • 1996
  • Reticle seekers temporally modulate target location onto the incoming spatial signal. When large or multiple targets are present in the FOV, however, it is hard to precisely modulate the incoming target signal by the relicle. To solve this loss of modulatoin depth problem, we present an improved retical seeker using the segmented focal plane array(FPA). The new reticle system uses the normalized difference as well as the modulated signal of each detector output in the segmented FPA. In simulation, we have ascertained the proposed system can make an effective analysis and tracking for multiple or large targets.

  • PDF