• Title/Summary/Keyword: FoM

Search Result 274, Processing Time 0.028 seconds

The effecal of irradiance during leaf development on photoinhibition in Panag ginseng C. A. Meyer

  • Parmenter, Graeme;Littlejohn, Roger
    • Journal of Ginseng Research
    • /
    • v.22 no.2
    • /
    • pp.102-113
    • /
    • 1998
  • This experiment used chlorophyll fluorescence techniques to assess the effect of irradiant during leaf development on photoinhibition of photosynthesis in Panax ginseng. Seedlings of p. ginseng were grown in the 91asshouse at four shade levels. The maximum mid-day irradiant in each treatment between emergence (January 4) and completion of the experiment (February 25) was 1220, 485, 235, 125 $\mu$mol/$\textrm{m}^2$/s. To assess the rapidity of photosynthetic readaptation to changes in light levels, fluorescence parameters (Fo, F, Fm, Fm', AF/Fm;, Fv/Fm) were measured for three days before and after transfer of plants (on February 21) from each light treatment into each of the other light treatments. Before transfer, dark adapted values of Fv/Fm in the 1220 (0.699) and 485 (0.739) treatments were different from each other and lower than values in the 235 (0.764) and 125 (0.768) treatments, indicating mild photoinhibition. Patterns of change in F during the day also differed between treatments, with low light treatments tracking irradiant levels, but F in the high light treatment (1220) declined in the morning, presumably due to fluorescence quenching. Although plants grown at high irradiant had relatively low photosynthetic efficiency, relative electron transport rate was greater than in lower irradiant treatments. After transfer, plants adopted the daily pattern of change in F of the treatment to which they were moved with little change in absolute levels of F, except in plants transferred from the highest (1220) to the lowest light level (125), where F increased over the course of the three days following transfer. After plants were transferred, Fm' converged on values similar to those in plants raised in the treatments to which they were moved. Values of Fv/Fm in plants moved from low to high light declined dramatically, but there was no decline in plants from 485 moved to 1220. Values of Pv/Fm in plants that were moved from high light to lower light increased to values above those recorded in plants raised in the lower light treatments. Reductions in quantum efficiency caused by photoinhibition at high irradiant may be more than compensated for by higher electron transport rates, although evidence suggests that under high irradiant this tends to be balanced by reduced leaf area and earlier senescence. Chlorophyll fluorescence techniques appear capable of indicating effects of irradiant induced stress in ginseng, yielding results comparable to those obtained with gas exchange techniques but in less time and with greater replication.

  • PDF

12-bit SAR A/D Converter with 6MSB sharing (상위 6비트를 공유하는 12 비트 SAR A/D 변환기)

  • Lee, Ho-Yong;Yoon, Kwang-Sub
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1012-1018
    • /
    • 2018
  • In this paper, CMOS SAR (Successive Approximation Register) A/D converter with 1.8V supply voltage is designed for IoT sensor processing. This paper proposes design of a 12-bit SAR A/D converter with two A / D converters in parallel to improve the sampling rate. A/D converter1 of the two A/D converters determines all the 12-bit bits, and another A/D converter2 uses the upper six bits of the other A/D converters to minimize power consumption and switching energy. Since the second A/D converter2 does not determine the upper 6 bits, the control circuits and SAR Logic are not needed and the area is minimized. In addition, the switching energy increases as the large capacitor capacity and the large voltage change in the C-DAC, and the second A/D converter does not determine the upper 6 bits, thereby reducing the switching energy. It is also possible to reduce the process variation in the C-DAC by proposed structure by the split capacitor capacity in the C-DAC equals the unit capacitor capacity. The proposed SAR A/D converter was designed using 0.18um CMOS process, and the supply voltage of 1.8V, the conversion speed of 10MS/s, and the Effective Number of Bit (ENOB) of 10.2 bits were measured. The area of core block is $600{\times}900um^2$, the total power consumption is $79.58{\mu}W$, and the FOM (Figure of Merit) is 6.716fJ / step.

The Evaluation of Adaptability of Three Ever-green Perennial Herbaceous South Korea Native Plants under In-door Light Intensities

  • Sang Yeob Lee;Kyungtae Park;Bo Kook Jang;Cheol Hee Lee;Ju Sung Cho
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2020.08a
    • /
    • pp.67-67
    • /
    • 2020
  • Though there is an on-going need for the diversity of ornamental plants for in-door environment, their growth and stress adaptability in comparatively low light intensity condition require further studies for implementation. Here investigates the growth and chlorophyll fluorescence parameters of Farfugium japonicum (L.) Kitam, Liriope muscari (Decne.) L.H.Bailey and Acorus gramineus Aiton under several light intensities which were based on common in-door environment. The growth measurement of the plants included the quantity, length, width and SPAD value of the leaves. Calculated values of Fm/Fo, Fv/Fm, Pi_Abs, ETo/RC and DIo/RC were used as the parameters of the chlorophyll fluorescence under 10, 50, 100 and 200 PPFD (μmol·m-2·s-1) light intensities. In-door plants group was put in a closed room allowing no other light sources for 10 weeks and the control group was put in glass-greenhouse for the same period. The overall in-door growth of L. muscari was not significantly different in all light intensities compared to the control group and even showed the higher SPAD values. Also, an increasing tendency of Pi_Abs value under 10 to 100 PPFD was observed implying that L.muscari could adapt well to in-door environment. Measurement of A. gramineus growth mostly showed the highest values in the control group especially in the number of the leaves. Nevertheless, chlorophyll fluorescence parameters showed no significant value difference between in-door and the control groups and thus, A. gramineus might have possibility of successful adaptation to in-door environment. F. japonicum showed deficient growth in plant height and leaf length compared to the control but, it seemed to be able to sustain ornamental value under in-door light intensities. Furthermore, Pi_Abs and DIo/RC values were increased under in-door light conditions suggesting potential adaptability of F. japonicum.

  • PDF

Aging Effects in the Two-phase Intermetallic compounds Based on Cr-doped $\textrm{Ll}_2\textrm{Al}_3\textrm{Ti}$ (Cr 첨가 $\textrm{Ll}_2\textrm{Al}_3\textrm{Ti}$기 2상 금속간화합물의 시효처리 효과)

  • Lee, Jae-Gyeong;Park, Jeong-Yong;O, Myeong-Hun;Wi, Dang-Mun
    • Korean Journal of Materials Research
    • /
    • v.9 no.10
    • /
    • pp.951-955
    • /
    • 1999
  • Two-phase Al-21Ti-23Cr alloy containing 20 vol.% $\textrm{Cr}_{2}\textrm{Al}$ as a second phase in the $Ll_2$ matrix is located in the two- phase region of the Al- Ti- Cr phase diagram at $1150^{\circ}C$, while in the three-phase region at $1000^{\circ}C$. Based on this result, the mechanical properties of the A1-21Ti-23Cr alloy were enhanced through the refined precipitation of the third phase in the $Ll_2$ matrix by aging the alloy below $1000^{\circ}C$. It was observed that a several ,m of the third phase precipitated in the $Ll_2$ matrix through aging at $800^{\circ}C$ and $1000^{\circ}C$, but the precipitation was not observed below $600^{\circ}C$. Furthermore, the third phase was more finely precipitated at $800^{\circ}C$ than at $1000^{\circ}C$. Although the third phase precipitated at $800^{\circ}C$ and at $1000^{\circ}C$, the compressive yield strength increased rapidly at $800^{\circ}C$ only. This is probably attributable to the refined precipitation of the third phase in the $Ll_2$ matrix. It is expected that the precipitation of the third phase. which was confirmed to be the TiAlCr phase, improves the mechanical properties by preventing crack propagation in the $Ll_2$ matrix.

  • PDF

A Case of Glycogen Storage Disease Type Ia Confirmed by Biopsy and Enzyme Assay (제Ia형 당원병 1례 (Glycogen Storage Disease , Type Ia))

  • Meen Sang-Ae;Rho Kwang-Sik;Kim Pyung-Kil;Jeong Hyeon-Joo;Park Young-Nyeon;Kim Myung-Joon;Kim Ji-Hong
    • Childhood Kidney Diseases
    • /
    • v.2 no.1
    • /
    • pp.77-81
    • /
    • 1998
  • The author exprienced a case of glycogen storage disease type Ia(GSD-I) in an 18-year-old male patient who was admitted to our hospital due to proteinuria and hypertension. he was suspected to have GSD when 12 years old because of his family history of short stature and hepatomegaly. On admission, physical examination revealed short stature, heparomegaly, and The diagnosis of GSD-I was confirmed by compatible liver biopsy finding and enzyme assay which erealeddeficiency of glcose-6-phosphatase if hepatocyte. Sympromatic treatment was done using antihypertensive drugs and allopurinol with diet control. The authors report a case of glycogen storage disease type Ia completely confirmed by typical clinical manifestation, pathologic findings of the liver and the kidney, and the result of enzyme assay which revealed deficiency of glucose-6-phosphatase in hepatocytes with brief review fo related literatures.

  • PDF

1-β-D-Arabinofuranosyl-cytosine Induces Chromosomal Breaks in vitro (In vitro에서 1-β-D-arabinofuranosyl-cytosine의 염색체 파열 유도)

  • Jeon, In-sang
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.12
    • /
    • pp.1186-1193
    • /
    • 2003
  • Purpose : Fragile sites are points on chromosomes which tend to break non-randomly when exposed to specific chemical agents or conditions of tissue culture. The chromosomal break induced by the antineoplastic drug, 1-${\beta}$-D-arabinofuranosyl-cytosine(Ara-c), was investigated to study the laboratory conditions in which the incidence of chromosomal break could be enhanced. Besides, the fragile sites induced by Ara-C were investigated and compared to the already known locations of the specific chromosomal alterations observed in specific neoplasms. Methods : T-lymphocytes from theree normal males and three females were cultured for 48 hours. Cells from each individual were exposed to the Ara-C for an additional 24 hours. After the caffeine was added during the last six hours culture, the metaphase chromosomes were prepared following the conventional method. A site was considered fragile if it was found to break two or more per 100 chromosomal breaks in more than four of six individuals tested. Results : Ara-C induced 252.1 chromosomal breaks per 100 mitotic cells and this result was significantly higher than that of the control, which induced 25.2 breaks(P<0.05). The incidence of the chromosomal break by Ara-C was higher, if cultured in the MEM-FA, which has no folic acid, than in the RPMI 1640 which contains enough folic acid(P<0.05). The most common break site by Ara-C was 3p14.2(FRA3B). There were 20 fragile sites induced by Ara-C. Among these 20 fragile sites, seven coincided with the locations of the mapped oncogenes, JUN, SKI, REL, N-MYC, FHIT, MET, ETS-1, and FOS. Conclusion : S phase specific chemotherapeutic agent, Ara-C, induced the expression of the chromosomal fragile sites effectively using the T-lymphocyte in vitro. Some of the fragile sites by Ara-C highly coincided with the oncogenes and neoplasm specific chromosome breakpoints. In this regard, the fragile sites reported here could provide the unknown neoplasm related chromosomal alternation points.

The Comparasion of the Dynamic Stereoacuity with Two-Rods Test and Three-Rods Test (이간계와 삼간계를 이용한 동적 입체시의 비교)

  • Shim, Hyun-Suk;Kim, Sang-Moon;Kim, Sang-Hyun;Kim, Young-Cheong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.377-384
    • /
    • 2015
  • Purpose: On this study, we measured and compared the dynamic stereoacuity by two-rods test (Howard-Dolman Test) and three-rods test. And we analyzed the correlation between PD and refractive error with dynamic stereoacuity. Methods: Dynamic stereoacuity of two-rods test and three-rods test at 2.5 m distance for 93 adults 93 (50 males, 43 females), mean age of $21.27{\pm}2.32$ (19~32) years old, were measured 5 times for two tests. Results: The mean of dynamic stereoacuity measured by two-rods test and three-rods test were $29.91{\pm}23.03sec$ of arc and $23.75{\pm}21.65sec$ of arc for total subjects, respectively. The mean of male and female were $36{\pm}22.38sec$ of arc and $22.28{\pm}23.79$, respectively. Three-rods test showed better dynamic stereoacuity than two-rods test, but there was no statistically significant difference (p>0.05). For the average standard deviation of PD between 60.63 mm~66.19 mm, dynamic stereoacuity fo two-rod test and three-rod test were $31.48{\pm}24.87sec$ of arc and $31.48{\pm}24.87sec$ of arc, respectively. The results showed statistically significant difference (p<0.05), but the relationship between dynamic stereoacuity and PD was not great. Comparison between two tests on the basis of refractive error, dynamic stereoacuity by three-rods test was better than by two-rods test with no significant difference between both tests (p>0.05) and there was little correlation between refractive error and two dynamic stereoacuity. Conclusions: Three-rods test showing lower stereoacuity than two-rods tests could measure the lower minimum threshold of dynamic stereoacuity. It was found that both tests can be applied to dynamic stereoacuity test as a standard test, and PD and refractive error was found that little effect upon the dynamic stereoacuity. PD and refractive error was found that little effect upon the dynamic stereoacuity.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Causes of Right Middle Lobe Syndrome -Recent Experience in Local Tertiary Hospital for Several Years- (우중엽증후군의 원인 -최근 수년간 지역 3차 병원의 경험-)

  • Kim, Hyun Ok;Ma, Jeong Eun;Lee, Seung Jun;Cho, Yu Ji;Jeong, Yi Yeong;Jeon, Kyoung-Nyeo;Kim, Ho Cheol;Lee, Jong Deok;Hwang, Young Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.3
    • /
    • pp.192-196
    • /
    • 2007
  • Background: Right middle lobe syndrome (RMLS) is defined as transient or chronic and recurrent atelectasis of the right middle lobe. Although numerous conditions are associated with RMLS, there are very few recent reports in Korea. This study evaluated the causes of RMLS in a local tertiary hospitalover a period of 42 months. Method: Eighty-eight patients (M:F=64:22, mean age: $67.2{\pm}10.3years$), who had consistent chest radiography findings and underwent bronchoscopy in Gyeongsang University Hospital from January 2003 to July 2006, were enrolled in this study. The clinical characteristics and causes of RMLS in these patients were retrospectively reviewed. Results: The most common symptoms fo RMLS were cough, dyspnea and sputum. Tuberculosis was the most common cause (endobronchial tuberculosis in 22 and pulmonary tuberculosis in 1) The other causes were bronchial stenosis by benign fibrotic changes in 22 cases (25%), anthracofibrosis in 13 cases (14.8%), pneumonia in 11 cases (12.5%), lung cancer in 10 cases (11.4%), mucus impaction in 3 cases (3.4%), bronchiectasis in 2 cases (2.3%) and no demonstrable causes in 7 cases (8%). The bronchoscopy findings were mucosal edema with hyperemic changes in 38 cases (43.2%), mucosal edema with anthracotic pigmentation in 16 cases (18.2%), mucus impaction in 13 cases (14.8%), fibrotic stenosis in 13 cases (14.8%), a mass like lesion in 8 cases (9.1%), exudative necrotic material in 4 cases (4.5%), narrowing as a result of extrinsic compression in 2 cases (2.3%) and no demonstrable abnormalities in 12 cases (13.6%). Conclusion: Right middle lobe syndrome was observed more frequently in patients over the age of 65. The causes were mainly benign diseases with endobronchial tuberculosis being the most common.

Identification and Fermentation Characteristics of Lactic Acid Bacteria Isolated from Dongchimi as Starter for Radish Juice (무 쥬스 제조를 위한 starter로써 동치미에서 분리한 유산균의 동정 및 발효 특성)

  • Kim, Jung-Hee;Kim, Jong-Il
    • Korean Journal of Microbiology
    • /
    • v.35 no.4
    • /
    • pp.307-314
    • /
    • 1999
  • This study was aimed at the investigation of the possibility of the addition of lactic acid bacteria as "starter"for the preparation of radish juice. Forty strains of lactic acid bacteria were isolated from dongchimi that was fermented by a traditional method. The isolates were assorted into 5groups, Leuconostoc mesenteroides subsp. mesenteroides (J-9), Lacobacillus brevis (J-12), Lactobacillus fermentum (J-7), Lactobacillus sake (J-20), and Lactobacillus plantarum (J-39). Leuconostoc mesenteroides was predominated in the sample of dongchimi with frequency of 52.5%. Each of the strain, which exhibited the beat growth in the species, was selected in the 5species, and investigation of the fermentation characteristcis was carried out. The fermentation were performed for 9 days at 25${\circ}C$ after the inoculation of 0.3% ($10^{6}$ cfu/㎖) to each ultra-filtrated radish juice. The pH, total acidity, content of non-volatile organic acids were examined during the fermentation period. Lactobacillus plantarum showed the highest growth rate and the growth rate of Lactobacillus sake was the lowest. The pH (6.3-6.36) and total acidity (0.09-1.0 %) fo the ultrafiltrated radish juice before fermentation were changed to 3.2-4.3 and 0.65-1.2% after 9days, respectively. The changes of the pH and total acidity were related with the growth of the lactic acid bacteria; the better growth of lactic acid bacteria, the more rapid decrease of pH and increase of the total acidity. when the amount of non-volatile organic acids were estimated during fermentation, citric acid, malic acid, malonic acid, and succinic acid were decreased in all cases. However, the content of lactic acid increased with the progression of fermentation. L. mesenteroides (J-9), L. brevis (J-12) and L. fermentum (J-7) were chosen for the candidates of the starter for the lactic fermentation of radish juice based on the biochemical analysis and sensory evaluation.

  • PDF