• Title/Summary/Keyword: Fluoroscopic radiology

Search Result 36, Processing Time 0.022 seconds

A Study on Radiation Exposure Dose of Operator During Interventional Radiology Procedure (방사선 중재적 시술 중 시술자의 피폭선량에 대한 연구)

  • Jeon, Mi-Eun;Lim, Cheong-Hwan;Jung, Hong-Ryang;You, In-Gyu;Hong, Dong-Hee;Kang, Byung-Sam
    • Journal of radiological science and technology
    • /
    • v.35 no.3
    • /
    • pp.219-226
    • /
    • 2012
  • Interventional radiologists are not aware of the potential injury from procedures. The purpose of this study are to evaluate radiation exposure of interventional radiologist from intervention procedures and to develop guideline of the simple methods for decreasing their radiation exposure from intervention procedure. In this study, Dosimeters were used to monitor operator doses of radiation exposure in a broad range of procedures from 20 interventional radiologist during the periods of 3 months. And, we searched protection methods of each interventional radiologist. During TACE procedure, there was using 0.5 mmPb radiation protector decreased average 89.5 % of radiation exposure. Thicker radiation protector provide decreasing radiation exposure. And radiation exposure dose decreased average 47.7 % by using pulse fluoroscopic mode. Therefore, interventional radiologist should wear protective aprons, use active shielding, monitor their doses, and know how to poisoning themselves during the procedure and operate correct of the machines for minimum dose.

Development of Biodegradable Polymeric Membrane for Interventional Procedure: Preliminary Study (인터벤션 시술을 위한 생분해성 고분자막의 개발 : 예비연구)

  • Bang, Jung-Wan;Hyun, Chang-Yong;Kim, Tae-Hyung;So, Woon-Young;Kim, Jin-Tae;Kim, Sang-Sub;Jung, Hee Dong;Heo, Yeong Cheol
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.15-20
    • /
    • 2014
  • This study was to evaluate clinical feasibility of biodegradable polymeric membrane for interventional procedure in preliminary study. Bio-degradable polymetric membrane was produced into a solution by mixing hyaluronic acid powder with NaOH solution in a heating mantle. Three different concentrations of contrast media (10, 20, and 30 vol%) were added to the produced soluble powder, and vertical agitation was performed for 12 hours at a speed of 100 to 200 rpm at a room temperature. It was freeze dried for 24 hours at a temperature $80^{\circ}C$. Pressure on the freeze dried sample was exerted by a hydraulic press in order to form the freeze dried sample into a membrane. The membrane produced with varying contrast medium concentration was visually examined by a scanning electron microscope and radiographically inspected. Under the visual examination, the higher the concentration of contrast medium, the rougher the surface. Radiographic transparency was similar under all conditions of fluoroscopic radiography, simple radiography, and serial radiography. In conclusion, this preliminary study verified that bio-degradable membrane produced with hyaluronic acid was a material with clinical usability.

A Mouse Colon Model to Investigate Stent-Induced Tissue Hyperplasia (쥐 대장에서 스텐트 삽입 후 발생하는 조직 과증식 모델 형성을 위한 연구)

  • Kim, Min Tae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.439-445
    • /
    • 2020
  • The purpose of this study was to investigate the feasibility of stent placement and the evaluation of tissue hyperplasia caused by bare metallic stent placement in a mouse colon model. In a pilot study, C57BL/6 mouse were used to verify diameter of colon. Mean diameter size was 4.05 mm. Twenty C57BL/6 mice were divided into two groups to assess differing stent diameters (Group A, 5 mm diameter; Group B. Group B, 4 mm diameter). Follow-up, 1-week fluoroscopic imaging, 4-week endoscopic imaging were obtained. Mice were sacrificed 4-week after stent placement. Microscopic findings were evaluated. Stent placement was technically successful except one mouse in Group A. Data from the mouse was omitted. During follow-up, five mice in Group A died within 7 days after stent placement, and one stent in Group B was migrated into the rectum. The incidence of stent-related complication was 60% and 10% between group A and Group B, respectively. Gross and Endoscopic findings showed tissue hyperplasia through the mesh, and all the stents had become incorporated into the wall of the colon. Microscopic findings were no statistically significant difference. colonic stent placement was technically feasible, and stent-induced tissue hyperplasia was evident in a mouse model. With stent large size, there was the highest incidence of colon perforation.

Balloon Dilatation of Bronchial Stenosis in Endobronchial Tuberculosis (기관지결핵에 의한 기도협착에서 풍선카테터를 이용한 기도확장요법)

  • Chung, Hee-Soon;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol;Kim, Woo-Sung;Im, Jung-Gi
    • Tuberculosis and Respiratory Diseases
    • /
    • v.38 no.3
    • /
    • pp.236-244
    • /
    • 1991
  • The prevalence rate of pulmonary tuberculosis is 1.8% in 1990, and endobronchial tuberculosis may exist in 10 to 40% of active disease. Endobronchial tuberculosis usually leaves bronchial stenosis as the complication despite of modern chemotherapy, and it is often misdiagnosed as bronchial asthma. When bronchial stenosis involves major airway, its treatment needs such special measures as steroid therapy, surgical intervention and/or laser therapy, but the therapeutic result is often disappointing. To exploit a new treatment modality for bronchial stenosis, balloon dilatation was carried out in 12 patients with endobronchial tuberculosis. Under local anesthesia, 4F-Fogarty balloon was inserted via bronchofiberscope in ten cases and 10F-Gruentzig balloon was introduced under fluoroscopic guide in two others. Endobronchial tuberculoses were subdivided into two(16.7%) with actively caseating type, seven (58.3%) with fibrostenotic type, and three (25.0%) with stenotic type without fibrosis, according to the bronchoscopic findings. In 7 healed cases which were all stenotic with fibrosis, three (42.9%) took favorable turn in clinical status but four (57.1%) were not improved with balloon dilatation. In 5 active cases, all (two with actively-caseating type and three with stenotic type without fibrosis) were improved with this method. $FEV_{1.0}$ or FVC increased 10% or more after procedure in seven (70.0%) of ten and bronchial lumen remained enlarged in eight (66.7%) of twelve, in whom follow-up examination was done after the procedure. Balloon dilatation of bronchial stenosis is more effective, when endobronchial tuberculosis is in active stage than in healed fibrotic stage. It is suggested that bronchial stenosis can be minimized by early diagnosis and early application of balloon dilatation in the course of disease.

  • PDF

The effect of Percutaneous pig-tail catheter drainage in the management of lung abscess and empyema (폐 농양및 농흉 치료에서 Pig-tail 도관 배액술의 효과)

  • Kim, Yeon Sao;Kim, Seong Min;Kim, Jin Ho;Lee, Kyung Sang;Yang, Suck Chul;Yoon, Ho Joo;Shin, Dong Ho;Park, Sung Soo;Lee, Jung Hee;Choi, Yo Won;Jean, Seok Chol;Kim, Young Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.571-578
    • /
    • 1996
  • Background : Long abscess is an accumulation of pus within a destroyed portion of the lung. Antibiotic therapy and postural drainge has proven to be an effective method of treatment for the majority of patients with pyogenic lung abscess. When medical therapy fails, thoracotomy and pulmonary resection are the current therapies. empyema is pus in the pleural space, and this term is deserved for effusions on which the Gram stain of the pleural fluid is positive. Initially, such collection may be drained via chest tribe. Recently, in patients who are judged to be unsuitable for surgery are in poor condition, percutaneous drainage using pig-tail catheter has been performed. We report out experience with 10 cases of lung abscess and 23 cases of empyema who were treated by percutaneous pit-tail catheter drainage. Subjects and Methods : Our study included 10 patients with lung abscess and 23 patients with empyema who were treated by percutaneous pig-tail catheter drainage, from January, 1990, to May, 1996, at Hanyang University then a pig-tail catheter was inserted into the abscess or the site of empyema under fluoroscopic and ultrasonograpic guidance. Following aspiration, the catheter was sutured into the skin, and connected to the suction tip. Catheter drainage was discontinued when the abscess of empyema was resolved in radiologically and clinically. Results : There were 2 cases of lung abscess caused by Staphylococcus aureus and Klebsiella pneumoniae and 14 cases of empyema caused by M. tuberculosis. The others were unknown. The duration of drainage was 1-2 weeks in 7 cases of lung abscess and 14 cases of empyema. In the 29 of 33 patients, percutaneous drainage were carried out successfully 20 of the 29 Gases rapidly improved. Conclusion : Percutaneous drainge is effective and relatively saute for management of lung abscess or empyema refractory to medical therapy or poor candidates for surgical treatment.

  • PDF

Mid-Term Results of Fixed Bearing Unicompartmental Knee Arthroplasty: Minimum 5-Year Follow-Up (고정형 슬관절 단일 구획 치환술의 중기 추시 결과: 최소 5년 추시)

  • Oh, Jeong Han;Joo, Il-Han;Kong, Dong-Yi;Choi, Choong-Hyeok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.498-504
    • /
    • 2018
  • Purpose: To evaluate the clinical and radiological outcomes, and the complications of unicompartmental knee arthroplasty (UKA) using a fixed bearing prosthesis after 5-year follow-up. Materials and Methods: Twenty-six knees (25 patients) that underwent fixed bearing UKA between May 2003 and August 2011 were included. The subjects were 3 males (3 knees) and 22 females (23 knees), and the average age was 63.5 years. The preoperative diagnosis was osteoarthritis (23 knees) and osteonecrosis (3 knees). The mean follow-up duration was 67 months (from 60 to 149 months). The clinical evaluation included pre- and postoperative American knee society knee and function score, and range of motion. The radiology evaluation included standing antero-posterior, lateral view, and fluoroscopic film to analyze the postoperative alignment and osteolysis. Results: The mean American Knee Society knee score and function score were improved from 42.0 and 57.5 to 87.9 and 85.0, respectively (p<0.001). The mean preoperative and postoperative range of motion was $132.9^{\circ}$ and $132.5^{\circ}$, respectively. The mean femorotibial angle were varus $0.5^{\circ}$ preoperatively and valgus $2.2^{\circ}$ postoperatively. A radiolucent line was observed in 2 knees; one knee had a stable implant, while in the other knee, patellofemoral arthritis was identified during UKA. Diffuse pain of the knee joint with tenderness of the medial joint line was identified at the follow-up, so conversion to total knee arthroplasty was recommended. No other complications, such as osteolysis, infections, postoperative stiffness, and dislocation, were encountered. Conclusion: The midterm results of fixed bearing UKA were clinically and radiologically satisfactory.