• Title/Summary/Keyword: Fluorophore

Search Result 78, Processing Time 0.036 seconds

Real Time Scale Measurement of Inorganic Phosphate Release by Fluorophore Labeled Phosphate Binding Protein (형광단이 붙어 있는 인산결합 단백질에 의한 인산 배출의 실시간 측정)

  • Jeong Yong-Joo
    • Journal of Life Science
    • /
    • v.15 no.6 s.73
    • /
    • pp.935-940
    • /
    • 2005
  • Fluorescence change of coumarin labeled phosphate binding protein (PBP-MDCC) was monitored to measure the amount of released inorganic phosphate ($P_{i}$) during nucleoside triphosphate (NTP) hydrolysis reaction. After purification of PBP-MDCC, fluorescence emission spectra showed that fluorescence responded linearly to $P_{i}$ up to about 0.7 molar ratio of $P_{i}$ to protein. The correlation of fluorescence signal and $P_{i}$ standard was measured to obtain [$P_{i}$] - fluorescence intensity standard curve on the stopped-flow instrument. When T7 bacteriophage helicase, double-stranded DNA unwinding enzyme using dTTP hydrolysis as an energy source, reacted with dTTP, the change of fluorescence was able to be converted to the amount of released $P_{i}$ by the $P_{i}$ standard curve. $P_{i}$ release results showed that single-stranded Ml3 DNA stimulated dTTP hydrolysis reaction several folds by T7 helicase. Instead of end point assay in NTP hydrolysis reaction, real time $P_{i}$-release assay by PBP-MDCC was proven to be very easy and convenient to measure released $P_{i}$.

Real-Time Localization of Parathyroid Glands with Near Infrared Light during Thyroid and Parathyroid Surgery (갑상선·부갑상선 수술 중 근적외선을 이용한 실시간 부갑상선의 국소화)

  • Kim, Sung Won;Jeong, Yeong Wook;Koh, Yoon Woo;Lee, Kang Dae
    • International journal of thyroidology
    • /
    • v.11 no.2
    • /
    • pp.92-98
    • /
    • 2018
  • Intraoperative identification and localization of parathyroid glands are crucial step in preventing postoperative hypocalcemia during thyroid and parathyroid surgery. If there is a method to predict the parathyroid's location rather than detecting and verifying with naked eye, it would make the operator easier to find and identify the parathyroid. Recently, near-infrared light imaging technologies have been introduced in the fields of thyroid and parathyroid surgery to predict the localization of the parathyroid. These are being conducted in two ways: autofluorescence imaging with a unique intrinsic fluorophore in the parathyroid tissues and fluorescence imaging with external fluorescence materials specially absorbed into parathyroid tissues. We are suggest that parathyroid glands can be detected by surgeon with NIR autofluorescence imaging even if they are covered by fibrofatty tissues before they are detected by surgeon's naked eye. These novel techniques are very useful to identify and preserve parathyroid glands during thyroidectomy. In this article, we reviewed the latest papers that describe autofluorescence imaging and exogenous ICG fluorescence imaging of parathyroid glands during thyroid and parathyroid surgery.

Assessment and Comparison of Three Dimensional Exoscopes for Near-Infrared Fluorescence-Guided Surgery Using Second-Window Indocyanine-Green

  • Cho, Steve S.;Teng, Clare W.;Ravin, Emma De;Singh, Yash B.;Lee, John Y.K.
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.4
    • /
    • pp.572-581
    • /
    • 2022
  • Objective : Compared to microscopes, exoscopes have advantages in field-depth, ergonomics, and educational value. Exoscopes are especially well-poised for adaptation into fluorescence-guided surgery (FGS) due to their excitation source, light path, and image processing capabilities. We evaluated the feasibility of near-infrared FGS using a 3-dimensional (3D), 4 K exoscope with near-infrared fluorescence imaging capability. We then compared it to the most sensitive, commercially-available near-infrared exoscope system (3D and 960 p). In-vitro and intraoperative comparisons were performed. Methods : Serial dilutions of indocyanine-green (1-2000 ㎍/mL) were imaged with the 3D, 4 K Olympus Orbeye (system 1) and the 3D, 960 p VisionSense Iridium (system 2). Near-infrared sensitivity was calculated using signal-to-background ratios (SBRs). In addition, three patients with brain tumors were administered indocyanine-green and imaged with system 1, with two also imaged with system 2 for comparison. Results : Systems 1 and 2 detected near-infrared fluorescence from indocyanine green concentrations of >250 ㎍/L and >31.3 ㎍/L, respectively. Intraoperatively, system 1 visualized strong near-infrared fluorescence from two, strongly gadolinium-enhancing meningiomas (SBR=2.4, 1.7). The high-resolution, bright images were sufficient for the surgeon to appreciate the underlying anatomy in the near-infrared mode. However, system 1 was not able to visualize fluorescence from a weakly-enhancing intraparenchymal metastasis. In contrast, system 2 successfully visualized both the meningioma and the metastasis but lacked high resolution stereopsis. Conclusion : Three-dimensional exoscope systems provide an alternative visualization platform for both standard microsurgery and near-infrared fluorescent guided surgery. However, when tumor fluorescence is weak (i.e., low fluorophore uptake, deep tumors), highly sensitive near-infrared visualization systems may be required.

Pancreatic Compression during Lymph Node Dissection in Laparoscopic Gastrectomy: Possible Cause of Pancreatic Leakage

  • Ida, Satoshi;Hiki, Naoki;Ishizawa, Takeaki;Kuriki, Yugo;Kamiya, Mako;Urano, Yasuteru;Nakamura, Takuro;Tsuda, Yasuo;Kano, Yosuke;Kumagai, Koshi;Nunobe, Souya;Ohashi, Manabu;Sano, Takeshi
    • Journal of Gastric Cancer
    • /
    • v.18 no.2
    • /
    • pp.134-141
    • /
    • 2018
  • Purpose: Postoperative pancreatic fistula is a serious and fatal complication of gastrectomy for gastric cancer. Blunt trauma to the parenchyma of the pancreas can result from an assistant's forceps compressing and retracting the pancreas, which in turn may result in pancreatic juice leakage. However, no published studies have focused on blunt trauma to the pancreas during laparoscopic surgery. Our aim was to investigate the relationship between compression of the pancreas and pancreatic juice leakage in a swine model. Materials and Methods: Three female pigs were used in this study. The pancreas was gently compressed dorsally for 15 minutes laparoscopically with gauze grasped with forceps. Pancreatic juice leakage was visualized by fluorescence imaging after topical administration of chymotrypsin-activatable fluorophore in real time. Amylase concentrations in ascites collected at specified times was measured. In addition, pancreatic tissue was fixed with formalin, and the histology of the compressed sites was evaluated. Results: Fluorescence imaging enabled visualization of pancreatic juice leaking into ascites around the pancreas. Median concentrations of pancreatic amylase in ascites increased from 46 U/L preoperatively to 12,509 U/L 4 hours after compression. Histological examination of tissues obtained 4 hours after compression revealed necrotic pancreatic acinar cells extending from the surface to deep within the pancreas and infiltration of inflammatory cells. Conclusions: Pancreatic compression by the assistant's forceps can contribute to pancreatic juice leakage. These findings will help to improve the procedure for lymph node dissection around the pancreas during laparoscopic gastrectomy.

Steady state and Lifetime Measurements of Primary Fluorescence from Phytoplanktons (식물플랑크톤 색소의 형광 특성과 lifetime 측정)

  • PARK Mi-Ok
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.24 no.6
    • /
    • pp.397-404
    • /
    • 1991
  • The steady state and decay characteristics of primary fluorescenece of phytoplanktons including Cyanophyceae and Cryptophyceae were investigated in vivo. At 580-640 nm region, fluorescence emission spectra were obtained from all algae examined. The observed fluorescence emission maxima were similiar$(\pm3\;nm)$ except Synechocorcus sp. (SYN). Considered $\lambda_{max}$ of emission spectra of phycobiliproteins and the excitation spectra with $\lambda_{max}=540-560nm$, it seems to be originated from biliproteins. Fluorescence lifetimes $(\tau)$ and decay curves were compared with standard solution of candidate organic compounds, b-phycoerythrin. The $\tau$ values obtained for phytoplankton with $\lambda_{max}=580nm$ were different depending upon the species of algae. The observed $\tau$ values were ranged from 1.39 ns to 1.95 ns. These are considerably shorter than $\tau(3.23\;us)$ for standard solution of b-phycoerythrin. The reduction of $\tau$ for phycoerythrin in vivo seems to be originated from effective energy transfer system between Chl. a and phycobiliprotein in intact cell. There are subtantial differences in fluorsecence spectra and lifetimes at the class level. At the species level, differences seems to be much smaller. The result of experiment suggests that measurement of fluorescence lifetimes may be helpful in the rapid characterization of algae. Direct application will likely be found in combination with the measurement of other luminescence parameters.

  • PDF

Effect of Overexpressed Ref-1 on AKT Phosphorylation for NO Production in Mouse Aortic Endothelial Cell Line (마우스 내피세포주 MAE의 NO 생성과정에서 과발현된 Ref-1의 AKT 활성 조절에 대한 연구)

  • Song, Ju-Dong;Lee, Sang-Kwon;Park, Young-Chul
    • Journal of Life Science
    • /
    • v.18 no.12
    • /
    • pp.1651-1656
    • /
    • 2008
  • Redox factor-1 (Ref-1) is essential for repair of oxidatively damaged DNA and also govern the reductive activation of many transcription factors. In this study, we examined the effect of overexpressed Ref-1 on AKT activation for nitric oxide (NO) production in mouse aortic endothelial (MAE) cells. Adenoviral-mediated overexpression of Ref-1 enhanced NO production in unstimulated- as well as bradykinin-stimulated MAE cells. Importantly, forced overexpression of Ref-1 induced direct phosphorylation of AKT in cells. And, a PI3K inhibitor wortmannin completely abolished the increase in AKT phosphorylation by stimulation of bradykinin and/or overexpressed Ref-1. In addition, inhibition of AKT activity with HA-tagged activation-deficient AKT suppressed Ref-1-induced endothelial NO synthase (eNOS) phosphorylation and resulted in a corresponding inhibition of unstimulated- and bradykinin-stimulated NO production. These results suggest that Ref-1 stimulates direct phosphorylation of AKT for eNOS enzyme activity in murine endothelial cells.

PET Imaging of Click-engineered PSMA-targeting Immune Cells in Normal Mice

  • Hye Won Kim;Won Chang Lee;In Ho Song;Hyun Soo Park;Sang Eun Kim
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.2
    • /
    • pp.53-61
    • /
    • 2022
  • This study aimed to increase the targeting ability against PSMA in cell therapy using metabolic glycoengineering and biorthogonal chemistry and to visualize cell trafficking using PET imaging. Cellular membranes of THP-1 cells were decorated with azide(-N3) using Ac4ManNAz by metabolic glycoengineering. Engineered THP-1 cells were conjugated with DBCO-bearing fluorophore (ADIBO-Cy5.5) for 1 h at different concentrations and analyzed by confocal fluorescence microscopy and flow cytometry. For PSAM ligand conjugation to THP-1 cells, Ac4ManNAz treated THP-1 cells were incubated with DBCO-PSMA ligand (ADIBO-GUL) at a final concentration with 100 µM for 1 h. To evaluate the effect on cell recognition, PSMA ligand conjugated THP-1 cells(as effectors) were co-cultured with PSMA positive 22RV1 (as target cells) at 3 : 1 a effector-to-target cell (E/T) ratio. The interaction between THP-1 and 22RV1 was monitored by confocal fluorescence microscopy. For preparing the radiolabeled THP-1, the cells were treated at the activity of ~ 740 kBq of [89Zr]Zr(oxinate)4/5 × 106 cells. Radiolabeled cells were analyzed for determination of cell-associated radioactivity by gamma counting and viability using MTS assay. In the cytotoxicity assay, THP-1 cells did not have any cytotoxicity even when the Ac4ManNAz concentration was 100 µM. In confocal microscopy and flow cytometry, THP-1 cells were efficiently labeled ADIBO-Cy5.5 in a dose-dependent manner, and the dose of 100 µM was the optimal concentration for the following experiments. The clusters of PSMA ligand-conjugated THP-1 cells and 22RV1 cells were identified, indicating cell-cell recognition over the cell surface between two types of cells. Cell radiolabeling efficiency was 54.5 ± 17.8%. THP-1 labeled with 0.09 ± 0.03 Bq/cell showed no significant cytotoxicity compared to unlabeled THP-1 up to 7 days. We successfully demonstrated that Ac4ManNAz treated cells were efficiently conjugated with ADIBO-GUL for preparing the PSMA-targeting cells, and [89Zr]Zr(oxinate)4 could be used to label cells without toxicity. It suggested that PSMA-ligand conjugated cell therapy could be improved cell targeting and be monitored by PET imaging.

CONFOCAL LASER SCANNING MICROSCOPIC MORPHOLOGY OF DENTIN-RESIN INTERFACE AND ITS RELATIONSHIP WITH SHEAR BOND STRENGTH (상아질-레진 계면의 공초점 현미경적 형태 및 전단결합강도와의 관계)

  • Choi, Nak-Won;Cho, Byeong-Hoon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.310-321
    • /
    • 1999
  • In this in vitro study, confocal laser scanning microscopic morphology of dentin-resin interface and its relationship to shear bond strength were investigated after the exposed dentin surfaces were treated with 3 different kinds of dentin adhesive systems[three-step; Scotchbond Multi-Purpose Plus(SMPP), self-priming bonding resin; Single Bond(SB), self-etching primer; Clearfil Liner Bond 2(LB2)]. 52 extracted human molar teeth without caries and/or restorations. The experimental teeth were randomly divided into three groups of seventeen teeth each. In five teeth of each group, class V cavities(depth: 1.5mm) with 900 cavosurface angles were prepared at the cementoenamel junction on buccal and lingual surfaces. Bonding resins of each dentin adhesive system were mixed with rhodamine B. Primer of SMPP was mixed with fluorescein. In group 1. the exposed dentin was conditioned with etchant, applied with above primer and bonding resin of SMPP. In group 2, with etchant and self-priming bonding agent of SB. In group 3, with self-etching primer and bonding agent of LB2. After treatment with dentin adhesive systems, composite resin were applied and photocured. The experimental teeth were cut longitudinally through the center line of restoration and grounded so that about $90{\mu}m$-thick wafers of buccolingually orientated dentin were obtained. And, $70{\sim}80{\mu}m$-thick wafers sectioned horizontally, thus presenting a dentinal tubules at 900 to the cut surface of a remaining tooth, were obtained. Primer of SMPP mixed with rhodamine B was applied to these wafers. Confocal laser scanning microscopic investigations of these wafers were done within of 24 hours after treatment. To measure shear bond strength, the remaining twelve teeth of each group were grounded horizontally below the dentinoenamel junction, so that no enamel remained. After applying dentin adhesive systems on the dentin surface, composite was applied in the shape of cylinder. The cylinder was 5mm in diameter, and 2mm in thickness. Shear bond strength was measured using Instron with a cross-head speed of 0.5mm/min. It was concluded as follows ; 1. Hybrid layer of SMPP(mean: $4.56{\mu}m$) was thicker than that of any other groups. This value was not statistically significant thicker than that of SB(mean: $3.41{\mu}m$, p>0.05), and significant thicker than that of LB2(mean: $1.56{\mu}m$, p<0.05). There was a statistical difference between SB and LB2(p<0.05). 2. Although there were variations in the length of resin tag even in a sample, and in a group, most samples in SMPP and SB showed resin tags extending above $20{\mu}m$. But samples in LB2 showed resin tags of $10{\mu}m$ at best. 3. Besides primer's infiltration into demineralized peritubular dentin and dentinal tubules, fluorophore of primer was detected in the lateral branches of dentinal tubules. 4. All groups demonstrated statistically significant differences from one another(p<0.05), with shear bond strengths given in descending order as follows: SMPP(18.3MPa), SB(16.0MPa) and LB2(12.4MPa). 5. LB2 having thinnest hybrid layer($1.56{\mu}m$) showed the lowest shear bond strength(12.4MPa).

  • PDF