Study on Plasma Treatment of electrode for CCFL (CCFL 전극의 플라즈마 처리에 관한 연구)

  • Park, Hyun-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.3
    • /
    • pp.1308-1312
    • /
    • 2011
  • CCFL(Cold Cathode Fluorescent Lamp)for BLU of LCD and special lighting has been widely utilized. The removal of oxide film formed on electrode of CCFL in manufacturing process is required. In this pape Plasma treatment was carried out to remove the oxide film. To ensure the optimum process, the analysis of sheet resistance, XRD, AFM and solder test was conducted. A minimum sheet resistance and the maximum percentage of the solder coverage ratio were measured in optimal process conditions such as plasma power consumption 600W and processing time of 70 seconds. As the plasma treatment is confirmed to be due to removal of copper oxide, this process is expected to be used as a treatment of electrode for CCFL.

Fabrication and Characteristics of Flat Fluorescent Lamp (평판형광램프의 제작 및 특성)

  • 권순석;임민수;임기조
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.8-12
    • /
    • 2002
  • In this paper, we studied a flat fluorescent lamp with high luminance for LCD backlighting. The lamps have simple structures with ITO glass, insulator layer, phosphor layer, electrode layer and gas gap. The firing voltage was decreased with increasing the frequency. It was considered that this tendency was resulted from the space charge effect due to Xe and Ar positive ions trapped in gas gap. Decrease of uniform voltage at higher drive frequency is due to the remaining space charges which are produced by preceding period. As a result, luminance of 2700[cd/m$^2$] and maximum luminous efficiency of 51[m/W] were obtained with luminance uniformity of 96[%] in operation(700[V$\_$rms/], 80[kHz].

A Fluorescent Lamp Modeling for Inductor Ballast (인덕터 안전기용 형광램프 모델링)

  • 이진우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.9-14
    • /
    • 2004
  • The fluorescent lamp has been successfully modeled by employing the radial variation of particle density and considering driving circuit effects on the characteristics of discharge process. The electron energy distribution is assumed to have a Maxwellian. The electron mobility and the ambipolar diffusion coefficients are considered to vary with an electron energy rather than a simple uniform value. Energy states of mercury atom in the discharge process are regarded as six levels rather than simple 4 or 5 levels. These discharge processes have been accurately solved by numerically employing mixed the FDM and the 2nd Runge-Kutta method. This model was applied to analyzing real circuit. Simulation and experimental results were presented to verify the feasibility of the modeling. Simulation and experimental results were presented to verify the feasibility of the modeling.

Scanning backlight Driver for Mercury free flat fluorescent lamp (무수은 면광원 램프용 Scanning Backlight 구동회로)

  • Oh, Eun-Tae;Jung, Yong-Min;Lee, Kyung-In;Yoo, Ho-Won;Lee, Jun-Young
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.553-555
    • /
    • 2008
  • 현재 사용하고 있는 LCD(Liquid Crystal Display) Backlight용 램프는 주로 CCFL(Cold Cathod Fluorescent Lamp)과 EEFL(External Electrode Fluorescent Lamp)이 사용되고 있다. 하지만 이 램프는 수은을 사용하여 RoHS(the Restriction of the use of certain Hazardous Substances in electrical and electronic equipment)규제가 점점 강화되면서 사용이 제한되고 있으며, 이에 따라 수은을 사용하지 않는 램프의 제작이 불가피해지고 있다. 또한 LCD TV는 CRT와 PDP와는 다른 LCD만의 Hold-type 특성과 LC(Liquid Crystal)의 응답속도로 인하여 Motion Blur현상이 나타나는 단점이 있다. 본 논문에서는 RoHS 규제를 만족시키는 무수은 면광원 램프를 구동하기 위한 인버터를 제안한다. 제안한 인버터는 포워드 방식을 사용하여 반도체 소자 및 자기 소자의 수를 줄여서 구동회로가 간단하다. 또한 면광원 램프를 세로방향으로 6블록으로 나누어 스캔구동을 하여 Motion Blur현상을 저감 시켰다. 끝으로 실험을 통하여 제안한 인버터의 유용성을 입증하였다.

  • PDF

Electrical Characteristics of the Contour-Vibration-Mode Piezoelectric Transformer using PNW-PMN-PZT Ceramics (PNW-PMN-PZT세라믹스를 이용한 윤곽진동모드 압전트랜스포머의 전기적특성)

  • 류주현;오동언
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.7
    • /
    • pp.602-608
    • /
    • 2002
  • In this study, microstructural and piezoelectric characteristics of PNW-PMN-PZT ceramics manufactured using attrition milling method were investigated. Sintering temperature of the ceramics was varied from $1080^{\circ}C$ to $1240^{\circ}C$. With increasing sintering temperature, dielectric constant increased. In the specimen sintered at $1120^{\circ}C$, electromechanical coupling factor(Kp) and density showed the maxinum values of 0.546 and 7.78[$g/\textrm{cm}^3$], respectively. In the specimen sintered at $1160^{\circ}C$, mechanical quality factor(Qm) also showed the maxinum value of 1,943. Contour vibration mode piezoelectric transformer with the size of $27.5{\times}27.5{\times}2.5mm$ using PNW-PMN-PZT ceramics was manufactured and its driving characteristics for T5 fluorescent lamp was investigated. Taking into consideration temperature rise of 6.8[$^{\circ}C$] and efficiency of 98.23%, it can be concluded that the transformer is suitable for driving the T5 fluorescent lamp.

Flat Fluorescent Lamp(EEL) and LCD TV Backlight Using EEL as a Light Source (면광원 램프 및 이를 이용한 LCD TV용 백라이트)

  • Park, Jong-Lee;Kim, Chung-Soo;Lim, Sung-Kyoo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.14 no.2 s.43
    • /
    • pp.1-8
    • /
    • 2007
  • A flat fluorescent lamp (FFL) was developed as a light source for LCD TV Backlight. The channels of FFL were realized by forming the flat glass at high temperature. The performance of the backlight with FFL was shown to improve by optimizing the FFL channel profile that has elliptical shape, 4.4 mm height and 1.4 mm sealing distance. In this paper, the brightness uniformity of LCD TV backlights was investigated by optical simulation of FFL channel profiles. The brightness of LCD TV using FFL with the optimized channel profile was shown to be $576\;cd/m^2$.

  • PDF

Luminescent Characteristics of External Electrode Fluorescent Lamp(EEFL) for LCD Backlight Applications (LCD Backlight용 외부전극 형광램프의 발광특성)

  • 이순석;임성규
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.12
    • /
    • pp.1016-1021
    • /
    • 2002
  • Luminescent characteristics of FLs were studied according to the structure of electrode for LCD backlight applications. The luminance and luminous efficiency of the FLs fabricated under same conditions were measured and evaluated as functions of magnitude of applied voltage and widths of external electrode. The luminance and luminous efficiency of CCFL at 12 V were 27600 cd/$m^2$ and 35.3 lm/w, respectively The luminance of EEFLS increased as the widths of external electrode increased, and the luminous efficiency of EEFLS showed to increase to 20 mm of electrode width) and to decrease at wider than 20 m of electrode widths. The luminance and luminous efficiency of EEFL with 20 mm of electrode widths were 21600 cd/$m^2$ and 26500 cd/$m^2$, 35.6 lm/w and 34.8 lm/w at 12 V, 14 V, respectively.

A Study on the Equivalent Model of an External Electrode Fluorescent Lamp Based on Equivalent Resistance and Capacitance Variation

  • Cho, Kyu-Min;Oh, Won-Sik;Moon, Gun-Woo;Park, Mun-Soo;Lee, Sang-Gil
    • Journal of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.38-43
    • /
    • 2007
  • An External Electrode Fluorescent Lamp (EEFL) has longer lifespan, higher power efficiency and higher luminance than a Cold Cathode Fluorescent Lamp (CCFL). Moreover, it is easy to drive them in parallel. Therefore, the EEFL is expected to quickly replace the CCFL in LCD backlight systems. However, the EEFL has more complex characteristics than the CCFL with a resistive component, because it has both a resistive component by plasma and a capacitive component by external electrode. In this paper, values of resistance and capacitance are measured at several power levels and at several operating frequencies. They are expressed by a numeral formula based on a linear approximation that represents the equivalent resistance and capacitance as a function of power. Then we made block diagram of the equivalent circuit model using numerical expressions. Simulation waveforms and experimental results are presented to verify the feasibility of the equivalent model.

Photoreactivation Study of Wastewater Treatment Effluent Disinfected by UV-disinfection for Water Reuse (용수재이용을 위한 하수처리 유출수의 UV 소독 후 광회복 조사)

  • 윤춘경;정광욱;함종화;전지홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.3
    • /
    • pp.84-93
    • /
    • 2003
  • Photoreactivation of microorganism following UV-disinfection is one of the research topics of interest in assessing the UV-disinfection performance. Apparent photoreactivation was examined under fluorescent lamp and solar radiation as well as in darkness. Total coliform, fecal coliform, and Escherichia coli were used as indicator microorganisms, and their concentration was monitored with time after UV-disinfection. Under the darkness, their initial concentration of 10∼30 MPN/100 mL increased to the level of 100 MPN/100 mL after 24 hours, which implied that part of damaged microorganisms by UV-disinfection might be repairable with time. Under the fluorescent lamp, photoreactivation was more apparent that their concentration increased up to 1,000 MPN/100 mL which might significantly impair the water uses specially in reuse of reclaimed wastewater. However, their concentration further decreased down to below 2 MPN/100 mL under the solar radiation primarily due to additional disinfection by solar radiation rather than photoreactivation. Samples not disinfected by UV-disinfection also demonstrated substantial decrease of their concentration under solar radiation from about 5,000 MPN/100 mL to less than 30 MPN/100 mL in 24 hours. But direct reuse of effluent without disinfection is not recommended because natural decay by solar radiation may take time and be affected by climatic conditions. The result suggests that photoreactivation of pathogenic microorganisms may not be concerned in agricultural reuse of reclaimed wastewater because solar radiation may provide further disinfection after UV-disinfection.

Discharge characteristics of Flat Fluorescent Lamp (FFL(Flat Fluorescent Lamp)의 방전 특정)

  • Kwon, Soon-Seok;Ryu, Jang-Ryeol
    • 전자공학회논문지 IE
    • /
    • v.44 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • This experiment was analysed the discharge characteristics of FFL(flat fluorescent lamp). FFL is operated by sine and pulse wave source. We use FFL which has the electrodes covered with dielectric, observed the discharge characteristics of FFL by V-Q Lissajous' figure. When FFL is operated with pulsed, the discharge current flows after the applied voltage is risen. When the duty ratio increases, the number of metastable xenon atoms seem to increase. Consequently, the 172nm radiation becomes strong as the duty ratio increases.