Browse > Article

Photoreactivation Study of Wastewater Treatment Effluent Disinfected by UV-disinfection for Water Reuse  

윤춘경 (건국대학교 지역건설환경공학과)
정광욱 (건국대학교 대학원 지역건설환경공학과)
함종화 (건국대학교 대학원 지역건설환경공학과)
전지홍 (건국대학교 대학원 지역건설환경공학과)
Publication Information
Magazine of the Korean Society of Agricultural Engineers / v.45, no.3, 2003 , pp. 84-93 More about this Journal
Abstract
Photoreactivation of microorganism following UV-disinfection is one of the research topics of interest in assessing the UV-disinfection performance. Apparent photoreactivation was examined under fluorescent lamp and solar radiation as well as in darkness. Total coliform, fecal coliform, and Escherichia coli were used as indicator microorganisms, and their concentration was monitored with time after UV-disinfection. Under the darkness, their initial concentration of 10∼30 MPN/100 mL increased to the level of 100 MPN/100 mL after 24 hours, which implied that part of damaged microorganisms by UV-disinfection might be repairable with time. Under the fluorescent lamp, photoreactivation was more apparent that their concentration increased up to 1,000 MPN/100 mL which might significantly impair the water uses specially in reuse of reclaimed wastewater. However, their concentration further decreased down to below 2 MPN/100 mL under the solar radiation primarily due to additional disinfection by solar radiation rather than photoreactivation. Samples not disinfected by UV-disinfection also demonstrated substantial decrease of their concentration under solar radiation from about 5,000 MPN/100 mL to less than 30 MPN/100 mL in 24 hours. But direct reuse of effluent without disinfection is not recommended because natural decay by solar radiation may take time and be affected by climatic conditions. The result suggests that photoreactivation of pathogenic microorganisms may not be concerned in agricultural reuse of reclaimed wastewater because solar radiation may provide further disinfection after UV-disinfection.
Keywords
Photoreactivation; Reactivation; UV-disinfection; Fluorescent lamp; Solar radiation; Wastewater; Water reuse;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Solar disinfection of drinking water and diarrhoea in Massai children: a controlled field trial /
[ Ronan,M.C.;E.M.Michael;J.Tina;G.G.Kevin;B.Joseph ] / Early Reports
2 Effects of high intensity light on Ultraviolet-Irradated and Non-Irradiated Fish Pathogenic Bacteria /
[ Liltved,H.;B.ladnfald ] / Water Research   DOI   ScienceOn
3 /
[ Alexander, J. Horne;Charles R. Glodman ] / Limnology
4 /
[ Ministry of Environment(M.O.E) ] / The Water Quality Reports of Wastewater Treatment Plant in 3-Quarter
5 Fecal coliform removal in wastewater treatment plants studied by plant counts and enzymatic methods /
[ Isabelle,G.;P.Crop;P.Servais ] / Water Research
6 /
[ George,T.;F.L.Burton ] / Wastewater Engineering(Treatment, Disposal, and Reuse)
7 Assessment of photoreactivation following ultraviolet light disinfection /
[ Koji,K.;N.Kamico;K.Yamamoto;S.Ohgaki ] / Water Science and Technology   DOI
8 /
[ Nelson,D.L.;M.C.Michael ] / Lehninger Principle of Biochemistry
9 UV Disinfection /
[ Lee,K.H.;S.C.Lee ] / Journal of Environmental Hi-Technology
10 Manual - Guidelines for water reuse /
[ US. EPA. ] / EPA/625/R-921004
11 /
[ Ron,C.;G.Tchobanoglous ] / Small and Decentralized Wastewater Management Systems
12 Assessment of Photo reactivation follow UV Light Disinfection /
[ Kashimada,K.;N.Kamikp;K.Yamamoto;S.Ohggaki ] / Water Science and Technology   DOI
13 /
[ Tokebe,K. ] / DNA Repair
14 /
[ Ministry of Environment ] / Guidelines for Setting Disinfection System in Wastewater Treatment Plant
15 Photoreactivation of enterohemorrhagic escherichia coli following UV disinfection /
[ Tosa,K.T.;T.Hirata ] / Water Research   DOI   ScienceOn
16 Solar disinfection(SODIS): simulation of solar radiation for global assessment and application for point-of-use water treatment in Haiti /
[ Peter,M.O.;P.Shanaban;F.P.Martin ] / Water Research   DOI   ScienceOn
17 /
[ National Water Research Institute ] / UV Disinfection Guidelines for Wastewater Reclamation and Disinfection Research Needs Identification
18 /
[ APHA ] / Standard Methods for the Examination of Water and Wastewater(19th Ed.)
19 UV Disinfection and its Facility /
[ Yeom,C.M.;S.H.Cho;H.W.Jung;J.Y.Yoon ] / Journal of the KSWW
20 Researches on the effect of light upon bacteria and other organisms /
[ Downes,A.;T.P.Blunt ] / Proc. R. Soc.
21 /
[ Snicer,G.A.;J.P.Mally,Jr.;A.B.Margolin;P.H.Shannon ] / UV inactivation of Viruses in Natural Water
22 Comparative effectiveness of UV wavelengths for the inactivation of Cryptosporidium parvum oocyts in water /
[ Linden,K.G.;G.Shin;M.D.Sobsey ] / Water Science and Technology
23 UV Disinfection for Drinking Water Treatment /
[ Lee,S.H. ] / KSWQ · KWWA Processing of 2002 fall conference