• 제목/요약/키워드: Fluorescence spectroscopy

검색결과 419건 처리시간 0.037초

Review of Neurosurgical Fluorescence Imaging Systems for Clinical Application

  • Kim, Hong Rae;Lee, Hyun Min;Yoo, Heon;Lee, Seung Hoon;Kim, Kwang Gi
    • Journal of the Optical Society of Korea
    • /
    • 제20권2호
    • /
    • pp.305-313
    • /
    • 2016
  • A number of fluorescence imaging techniques for use in the surgical removal of glioma have been developed over the course of the long history of neurosurgery. Various biomarkers, biochemical agents, and detection systems for glioma have also been developed. This review focuses on 5-aminolevulinic acid (5-ALA), which is used to detect glioma. Numerous forms of fluorescence-guided surgery use 5-ALA, which is helpful to the surgeon. The surgical microscope system is the observational method generally used with 5-ALA, while the loupe, endoscope, and exoscope are simpler alternatives. A system is needed for minimal resection and other issues that arise during neurosurgery. Such an enhanced system should be able to detect low-grade tumors and provide information on microinvasive diseases, resulting in an improved survival rate and better surgical skills. Development of systems that fulfill certain needs would help protect the brain function of the patient and broaden the use of such systems in neurosurgery.

Planar Laser-Induced Fluorescence (PLIF) Measurements of a Pulsed Electrothermal Plasma Jet

  • Kim, Jong-Uk;Kim, Youn J.;Byungyou Hong
    • Journal of Mechanical Science and Technology
    • /
    • 제15권12호
    • /
    • pp.1808-1815
    • /
    • 2001
  • The characteristics of a pulsed plasma jet originating from an electrothermal capillary discharge have been investigate using laser-induced fluorescence (LIF) measurement. Previous emission measurements of a 3.1 kJ plasma jet show trial upstream of the Mach disk the temperature and electron number density are about 14,000 K and and 10$\^$17/ cm$\^$-3/, while downstream of the Mach dick tole values are about 25,000 K and 10$\^$18/ cm$\^$-3/, respectively. However, these values are barred on line-of-sight integrated measurements that may be misleading. Hence, LIF is being used to provide both spatially and temporally resolved measurements. Our recent work has been directed at using planar laser-induced fluorescence (PLIF) imaging of atomic copper in the plasma jet flow field. Copper is a good candidate for PLIF studies because it is present throughout the plasma and has electronic transitions that provide an excellent pump-detect strategy. Our PLIF results to date show that emission measurements may give a misleading picture of the flow field, as there appeals to be a large amount of relatively low temperature copper outside the barrel shock. which may lead to errors in temperature inferred from emission spectroscopy. In this paper, the copper LIF image is presented and at the moment, relative density of atomic copper, which is distributed in the upstream of the pulsed plasma jet, is discussed qualitatively.

  • PDF

Diagnostics of Magnetron Sputtering Plasmas: Distributions of Density and Velocity of Sputtered Metal Atoms

  • Sasaki, Koichi
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.98-99
    • /
    • 2012
  • Deposition of thin films using magnetron sputtering plasmas is a well-developed, classical technology. However, detailed investigations using advanced diagnostics are insufficient in magnetron sputtering, in comparison with plasma-aided dry etching and plasma-enhanced chemical vapor deposition. In this talk, we will show examples of diagnostic works on magnetron sputtering employing metal targets. Diagnostic methods which have fine spatial resolutions are suitable for magnetron sputtering plasmas since they have significant spatial distributions. We are using two-dimensional laser-induced fluorescence spectroscopy, in which the plasma space is illuminated by a tunable laser beam with a planer shape. A charge-coupled device camera with a gated image intensifier is used for taking the picture of the image of laser-induced fluorescence formed on the planer laser beam. The picture of laser-induced fluorescence directly represents the two-dimensional distribution of the atom density probed by the tunable laser beam, when an intense laser with a relatively wide line-width is used. When a weak laser beam with a relatively narrow linewidth is used, the laser-induced fluorescence represents the density distribution of atoms which feel the laser wavelength to be resonant via the Doppler shift corresponding to their velocities. In this case, we can obtain the velocity distribution function of atoms by scanning the wavelength of the laser beam around the line center.

  • PDF

Raman and Fluorescence Studies of Thermotropic Liquid-Crystalline Oligomers with Different Type of Coils

  • Chae, Jong-Bok;Yu, Soo-Chang;Lee, Youn-Sik
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권2호
    • /
    • pp.193-199
    • /
    • 2007
  • Raman and fluorescence spectroscopies were employed to study the coil effects on the intermolecular structure of a rod-coil liquid crystalline (LC) oligomer, the esterification products of ethyl 4-[4'-oxy-4-biphenylcarbonyloxy]- 4'-biphenylcarboxylate with poly(propylene)oxides (PPO) (DP=12) and poly(ethylene oxide)s (PEO) (DP=12). Three different vibrational modes (carbonyl, aromatic C-H, and aromatic C=C) obtained from the Raman experiment at variable temperature indicate that PPO and PEO coils induce the hydrogen bonding in a different manner. Further information about the micro-environment around the mesogenic unit obtained by fluorescence excitation spectra of P12-4 (LC with PPO coil) and 12-4 (LC with PEO coil) suggests that the mesogenic unit of P12-4 is quite different from that of 12-4 in intermolecular structure. This study supports the results obtained only from Raman spectroscopy, providing more accurate information about the intermolecular structural changes of liquid crystalline polymers at a molecular level during the phase transitions.

Interaction of Norfloxacin with Super-Coiled DNA

  • Hwangbo, Hyun-Jung;Lee, Young-Ae;Park, Jung-Hag;Lee, Yong-Rok;Kim, Jong-Moon;Yi, Seh-Yoon;Kim, Seog K.
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권5호
    • /
    • pp.579-582
    • /
    • 2003
  • Norfloxacin, that inhibits the action of topoisomerase Ⅱ, binds to wide variety of DNA. The binding mode of this drug to double- and super-coiled DNA (ds- and scDNA) is compared in this study by various spectroscopic methods, including absorption, fluorescence, and circular dichroism(CD) spectroscopy. Hypochromism in the absorption band, negative and positive induced CD bands (respectively in 240-260 nm and 270-300 nm region) are apparent for the norfloxacin that bound to both the dsDNA and scDNA. A decrease in fluorescence is also noticed in the presence of both DNAs. Since the spectroscopic characteristics are the same for both complexes, it is imperative that the binding mode of the norfloxacin is similar in ds- and scDNA. In the presence of $Mg^{2+}$, which is a cofactor in the topoisomerase Ⅱ action, the fluorescence intensity of the scDNA-norfloxacin complex increased and the resulting fluorescence intensity and shape was identical to that in the absence of scDNA. Therefore, the addition of an excess amount of $Mg^{2+}$ may result in the extrusion of norfloxacin from scDNA.

폴리아크릴산 용액에서의 옥사카르보시안닌 색소분자의 회합현상에 대한 반응속도론적 연구 (Kinetic Studies of the Aggregation of 3,3'-Diethyl Oxacarbocyanine onto Polyacrylic Acid)

  • 이홍;임은숙;배현옥
    • 대한화학회지
    • /
    • 제38권11호
    • /
    • pp.792-799
    • /
    • 1994
  • 균일 수용액과 polyacrylic acid(PAA) 존재하에서 3,3'-diethyl oxacarbocyanine(DOC)의 spectra변화를 흡수 및 형광분광학적인 방법으로 연구하였다. 균일 수용액에서 DOC의 농도변화에 따른 흡수 spectra변화는 dimer의 형성에 기인하는 것으로 설명하였다. PAA의 존재하에서 P/D변화에 의한 형광세기의 변화는 흡수 분광학적 방법과 유사한 결과를 얻었다. PAA와 DOC의 상호작용의 반응속도론적인 연구를 흡수 및 형광 정지흐름법으로 수행하였다. PAA-DOC계에서 관측된 이완효과는 두 개의 이완과정이 존재한다고 가정함으로써 정량적으로 설명할 수 있었다.

  • PDF

탄소 나노튜브와 DNA와의 결합을 통한 나노-바이오 마커 응용 (Carbon Nanotube DNA Bioconjugates as Nano-Bio Markers)

  • 황응수;조승범;홍상현;정혜진;차창용;최재붕;김영진;백승현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.668-671
    • /
    • 2005
  • Carbon nanotubes exhibit strong fluorescence emissions in the region of near infrared regions where most biomolecules are transparent. Such signals are highly sensitive to environment variations as well as adsorption of specific biomolecules. In this research, single walled carbon nanotubes(SWNTs) are assembled with different types of DNAs and used to target specific types of DNAs. Dot blot investigations and corresponding raman spectroscopy observations demonstrated excellent selectivity of carbon nanotube-DNA bioconjugates. The results show possibility of using SWNT as generic nano-bio markers for precise detection of different kinds of genes.

  • PDF