• 제목/요약/키워드: Fluid-Structure Coupled Analysis

검색결과 181건 처리시간 0.029초

Hydroelastic Vibration Analysis of Structures in Contact with Fluid

  • Chung, Kie-Tae;Kim, Young-Bok;Kang, Ho-Seung
    • Selected Papers of The Society of Naval Architects of Korea
    • /
    • 제2권1호
    • /
    • pp.18-28
    • /
    • 1994
  • In the vibration analysis of submerged or floating bodies such as ships and offshore structures, the coupled system between fluid and structure should be considered using the compatibility conditions on the wetted surface. It is well known that the hydroelastic vibration analysis of structures in contact with fluid can be done by applying the finite element method(FEM) to structures and the boundary element method(BEM) to the fluid domain. However, such an approach is impractical due to the characteristics of the fully coupled added mass matrix of fluid on the entire wetted surface. To overcome this difficulty, an efficient approach based on a reanalysis scheme is proposed in this paper. The proposed method can be applied for cases of higher local modes and beam-like modes for which three-dimensional reduction factors are not known. The three dimensional reduction factors are not needled and thus the restrictions can be removed in the analyses of non-beam like modes or local vibration modes by considering fluid-structure interaction. The validity and calculation efficiency of the proposed method are proved through numerical examples.

  • PDF

전산구조진동/전산유체 기법을 연계한 저속 유동박리 유발 비선형 진동특성 연구 (Nonlinear Characteristics of Flow Separation Induced Vibration at Low-Speed Using Coupled CSD and CFD technique)

  • 김동현;장태진;권혁준;이인
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.140-146
    • /
    • 2002
  • The fluid induced vibration (FIV) phenomena of a 2-D.O.F airfoil system have been investigated in low Reynolds number incompressible flow region. Unsteady flows with viscosity are computed using two-dimensional incompressible Navier-stokes code. To validate developed Navier-Stokes code, steady and unsteady flow fields around airfoil are analyzed. The present fluid/structure interaction analysis is based on the most accurate computational approach with computational fluid dynamics (CSD) and computational structural dynamics (CSD) techniques. The highly nonlinear fluid/structure interaction phenomena due to severe flow separations have been analyzed fur the low Reynolds region (R$_{N}$ =500~5000) that has a dominancy of flow viscosity. The effect of R$_{N}$ on the fluid/structure coupled vibration instability of 2-DOF airfoil system is presented and the effect of initial angle of attack on the dynamic instability are also shown.own.

  • PDF

등가강성모델 기반의 양방향 유체구조 연성해석을 적용한 NREL Phase VI 풍력 로터 시스템의 공력특성 평가 (Evaluation of Aerodynamic Characteristics of NREL Phase VI Rotor System Using 2-Way Fluid-Structure Coupled Analysis Based on Equivalent Stiffness Model)

  • 차진현;송우진;강범수;김정
    • 대한기계학회논문집A
    • /
    • 제36권7호
    • /
    • pp.731-738
    • /
    • 2012
  • 본 논문은 상용 유한요소코드인 ANSYS Workbench 12.1과 CFX 12.1을 이용하여 NREL Phase VI Rotor에 대한 공력특성을 입구풍속 7m/s 경우에 대해 연구하였다. 공탄성 효과를 고려하기 위해 약결합 양방향 유체구조 연성기법을 사용하여 타워구조를 제외한 로터파트에 대해서 해석이 수행되었다. 블레이드 끝단의 초기 피치각은 $3^{\circ}$로 설정하였고, 구조해석모델은 등가강성기법을 적용하였다. 신뢰성 있는 수렴판정 결과의 확보를 위해 블레이드 루터부의 굽힘모멘트를 실시간으로 모니터링 하였다. 해석의 신뢰성을 검증하기 위하여 해석결과를 NREL/NASA Ames 풍동 실험결과와 비교 분석하였다.

면진된 유체저장탱크의 비선형 유체-구조물 상호작용 해석 (Analysis of Fluid-Structure Interactions Considering Nonlinear Free Surface Condition for Base-isolated Fluid Storage Tank)

  • 김문겸;임윤묵;조경환;정승원;어준
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.481-488
    • /
    • 2003
  • A fluid-structure-isolator interaction program was developed in this study. The behavior of liquid regions are simulated by the boundary element method, and then the technique of analyzing the free surface motion in time domain is developed by using the nonlinear free surface boundary condition(NFBC) and the condition of interface between the structure and the fluid. Structure regions are modeled by the finite element method. In order to construct the governing equation of the fluid structure interaction(FSI)problem in time domain, the finite elements for a structure and boundary elements for liquid are coupled using the equilibrium condition, the compatibility condition and NFBC. The isolator is simulated by equation proposedin 3D Basis Me. In order to verify the validity and the applicability of the developed fluid- structure -Isolator interaction program, The horizontal forced vibration analysis was performed. The applicability of the developed method is verified through the artificial seismic analysis of real size liquid storage tank.

  • PDF

고층건물의 풍하중 유발 진동해석 (Wind Load Induced Vibration Analysis for Tall Structure)

  • 김동현;김유성;김요한;김동만;이종욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.658-659
    • /
    • 2009
  • In this study, fluid-induced vibration (FIV) analyses have been conducted for tall building structure. In order to investigate the aeroelastic responses of tall building due to wind load, advanced computational analysis system based n computational fluid dynamics(CFD) and computational structural dynamics (CSD) has been developed. Fluid domains are modeled using the computational grid system with local grid deforming technique. A fully implicit time marching scheme based on the Newmark direct integration method is used for computing the coupled aeroelastic governing equations of tall structure for fluid-structure interaction (FSI) problems. Detailed aeroelastic responses and results are presented to show the physical phenomenon of the tall building.

  • PDF

Fully coupled FSI analysis of Francis turbines exposed to sediment erosion

  • Chitrakar, Sailesh;Cervantes, Michel;Thapa, Biraj Singh
    • International Journal of Fluid Machinery and Systems
    • /
    • 제7권3호
    • /
    • pp.101-109
    • /
    • 2014
  • Sediment erosion is one of the key challenges in hydraulic turbines from a design and maintenance perspective in Himalayas. The present study focuses on choosing the best design in terms of blade angle distribution of a Francis turbine runner which has least erosion effect without influencing the efficiency and the structural integrity. A fully coupled Fluid-Structure-Interaction (FSI) analysis was performed through a multi-field solver, which showed that the maximum stress induced in the optimized design for better sediment handling, is less than that induced in the reference design. Some numerical validation techniques have been shown for both CFD and FSI analysis.

경계요소-유한요소 연계법에 의한 구형 수조구조물의 동적거동 특성해석 (Analysis of Dynamic Behavior of Flexible Rectangular Liquid Containers by the Coupled Boundary Element-Finite Element Method)

  • 고현무;박장호;김재관
    • 대한토목학회논문집
    • /
    • 제14권5호
    • /
    • pp.1033-1042
    • /
    • 1994
  • 2차원 경계요소-유한요소 연계법을 사용하여 구형 수조구조물의 동적거동 특성을 파악하였다. 비점성, 비압축성 이상유체의 운동은 경계요소법으로 모델링하였으며 구조물의 운동은 유한요소법으로 모델링하였다. 경계요소법의 적용시 Singularity를 소거한 경계적분식을 사용하였다. 유체와 구조물의 경계면에서 적합조건과 평형조건을 만족시킴으로써 경계요소와 유한요소를 연계하였다. 유체-구조물 상호작용의 영향은 유체의 부가질량행렬과 유체 유동에 의한 강성행렬로 연계된 유체-구조물계에 반영된다. 연계된 유체-구조물계의 고유치 문제로부터 수조구조물의 고유진동수외 고유모드를 구하였으며 수평 및 수직 자바운동에 의하여 수조구조물에 발생하는 유체동압력과 자유수면의 유동도 산출하였다.

  • PDF

Seismic response analysis of an oil storage tank using Lagrangian fluid elements

  • Nagashima, Toshio;Tsukuda, Takenari
    • Coupled systems mechanics
    • /
    • 제2권4호
    • /
    • pp.389-410
    • /
    • 2013
  • Three-dimensional Lagrangian fluid finite element is applied to seismic response analysis of an oil storage tank with a floating roof. The fluid element utilized in the present analysis is formulated based on the displacement finite element method considering only volumetric elasticity and its element stiffness matrix is derived by using one-point integration method in order to avoid volumetric locking. The method usually adds a rotational penalty stiffness to satisfy the irrotational condition for fluid motion and modifies element mass matrices through the projected mass method to suppress spurious hourglass-mode appeared in compensation for one-point integration. In the fluid element utilized in the present paper, a small hourglass stiffness is employed. The fluid and structure domains for the objective oil storage tank are modeled by eight-node solid elements and four-node shell elements, respectively, and the transient response of the floating roof structure or the free surface are evaluated by implicit direct time integration method. The results of seismic response analyses are compared with those by other method and the validation of the present analysis using three-dimensional Lagrangian fluid finite elements is shown.

부가질량 효과와 호흡모드를 고려한 구조-유체연성진동해석 (The Effect of Added Mass of Water and Breath Mode in Fluid-Structure Coupled Vibration Analysis)

  • 배성용
    • 동력기계공학회지
    • /
    • 제9권4호
    • /
    • pp.71-76
    • /
    • 2005
  • Marine structures are often in contact with inner or outer fluid as stern, ballast and oil tanks. The effect of interaction between fluid and structure has to be taken into consideration when we estimate the dynamic response of the structure appropriately. Fatigue damages can also be sometimes observed in these tanks which seem to be caused by resonance. Thin walled tank structures in ships which are in contact with water and located near engine or propeller where vibration characteristics are strongly affected by the added mass of containing water. Therefore it is essentially important to estimate the added mass effect to predict vibration characteristics of tank structures. But it is difficult to estimate exactly the magnitude of the added mass because this is a fluid-structure interaction problem and is affected by the free surface, vibration modes of structural panels and the depth of water. I have developed a numerical tool of vibration analysis of 3-dimensional tank structure using finite elements for plates and boundary elements for fluid region. In the present study, the effect of added mass of containing water, the effect of structural constraint between panels on the vibration characteristics are investigated numerically and discussed. Especially a natural frequencies by the fluid interaction between 2 panels and a breath mode of the water tank are focused on.

  • PDF