• 제목/요약/키워드: Fluid shear stress

검색결과 401건 처리시간 0.024초

Synthesis and Electrorheological Effect of the Suspensions Composed of Nano Sized Hollow Polyaniline Derivatives

  • Choi Ung-Su
    • KSTLE International Journal
    • /
    • 제7권1호
    • /
    • pp.18-21
    • /
    • 2006
  • The electrorheology of hollow PANI derivative suspensions in silicone oil was investigated by varying the electric fields and shear rates, respectively. The hollow PANI derivative susepnsions showed a typical electrorheological (ER) response caused by the polarizability of an amide polar group and shear yield stress due to the formation of chains upon application of an electric field. The shear stress for the hollow PANI succinate suspension exhibited an electric field power of 0.67. On the basis of the experimental results, the newly synthesized hollow PANI derivative suspensions were found to be an anhydrous ER fluid.

뉴턴유체와 혈액의 맥동유동시 탄성혈관의 운동이 벽면전단응력분포에 미치는 영향 (Effects of Elastic Blood Vessel Motions on the Wall Shear Stresses for Pulsatile Flow of a Newtonian Fluid and Blood)

  • 노형운;김재수;박길문;서상호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.318-323
    • /
    • 2001
  • Characteristics of the pulsatile flow in a 3-dimensional elastic blood vessel are investigated to understand the blood flow phenomena in the human body arteries. In this study, a model for the elastic blood vessel is proposed. The finite volume prediction is used to analyse the pulsatile flow in the elastic blood vessel. Variations of the pressure, velocity and wall shear stress of the pulsatile flow in the elastic blood vessel are obtained. The magnitudes of the velocity waveforms in the elastic blood vessel model are larger than those in the rigid blood vessel model. The wall shear stresses on the elastic vessel vary with the blood vessel motions. Amplitude indices of the wall shear stress for blood in the elastic blood vessel are $4\sim5$ times larger than those of the Newtonian fluid. As the phase angle increased, point of the phase angle is are moved forward and the wall shear stresses are increased for blood and the Newtonian fluid.

  • PDF

A Paradigm for the Viscosity of Fluids

  • Kim, Won-Soo;Chair, Tong-Seek;Pak, Hyung-Suk
    • Bulletin of the Korean Chemical Society
    • /
    • 제9권4호
    • /
    • pp.213-217
    • /
    • 1988
  • A new paradigm for the viscosity of fluid is presented by considering the fact that the viscosity is equal to the shear stress divided by the shear rate. The shear stress is obtained from the sum of kinetic and internal pressures of fluid, and the shear rate is found from the phonon velocity divided by the mean free path of the phonon. The calculated viscosities for various simple substances are in excellent agreements with those of the observed data through the wide temperature range covered both of liquid and gas phase.

Effect of Wall Groove Characteristics on Yield Stress Measurement of Magnetorheological Fluid

  • Tian, Zuzhi;Guo, Chuwen;Chen, Fei;Wu, Xiangfan
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.281-285
    • /
    • 2017
  • To suppress the wall slip effect and improve the yield stress measurement precision of magnetorheological fluid, measurement disks with different grooves are first manufactured. Then, the influence of groove characteristics on the yield stress of magnetorheological fluid is investigated by the method of experiments. Finally, the optimization wall grooves of measurement disks are obtained, and the yield stress of a self-prepared magnetorheological fluid is measured. Results indicate that the groove type and groove width have a slight influence on the shear yield stress, whereas the measured yield stress increases with enhanced groove density, and the optimized groove depth is 0.3 mm. The measured shear yield stress of self-prepared MR fluid can be improved by 18 % according to the optimized grooved disks, and the maximum yield stress can reach up to 65 kPa as the magnetic flux density is 0.5 T.

MR 유체의 자기유동 특성에 대한 실험연구 (Experimental study on Magnetic Flow Characteristics of MR Fluid)

  • 이석현;김기영;백대성;권영철;박삼진
    • 한국산학기술학회논문지
    • /
    • 제14권8호
    • /
    • pp.3611-3616
    • /
    • 2013
  • MR 유체의 물리특성은 자기장에 의해 영향을 받는다. 본 연구에서는 MR 유체의 자기장에 의한 유동변화를 실험적으로 조사하고자, MR 유체의 밀도와 점도를 변경하면서 자기장에 의한 유동 가시화와 전단응력 변화를 측정하였다. 이를 위해 밀도 3종, 점도 3종에 대한 MR 유체를 제조하였고 MR 유체 가시화 실험장치를 제작하였다. 자기장이 인가되면, MR 유체 파우더의 유동흐름은 띠를 형성하면서 자기장이 인가되지 않은 경우와는 다른 유동흐름을 보여주었다. 또한 전단응력은 인가전류와 밀도가 높을수록 더 크게 증가하였으며, 인가전류 2.0A에서 MR 유체의 밀도가 $1300kg/m^3$에서 $1700kg/m^3$ 로 변하면 전단응력은 33% 정도 증가하였다.

부유식 폴리머 인공심장 밸브의 축대칭 혈류 해석 (Axisymmetric analysis of blood flow for a floating type polymer artificial heart valve)

  • 성현찬;정기석;김경훈;고형종;박찬영;민병구;심은보
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.703-704
    • /
    • 2002
  • The two major problems related to the blood flow in a floating type polymer valve are thrombus formation and hemolysis. It is well known that the shear stress in the fluid and flow separation around the valve are blamed for such disastrous phenomena. In this viewpoint, through study of the flow field around the valve is imperative to improve design of the valve. The aim of this study is to investigate the fluid flow around a floating type polymer valve. The numerical method employed in this study is the finite element software called ADINA. Incompressible viscous flow is assumed for blood using the assumption of Newtonian fluid. In this study, two prominent features of the axisymmetric flow around the floating type polymer valve are observed: jet-like flows observed near the gap between the conduit and the valve, and recirculating flow downstream of the valve. We also provided a detailed description of shear stress field according to the variation of flow conditions. The shear stress in fluid has its maximum value near the gap between the valve and the conduit.

  • PDF

전단 자극에 의한 심방 근세포 칼슘 웨이브의 발생: Phospholipase C-이노시톨 1,4,5-삼인산 수용체 신호전달의 역할 (Activation of a Ca2+ wave by Shear Stress in Atrial Myocytes: Role of Phospholipase C-inositol 1,4,5-Trisphosphate Receptor Signaling)

  • 김준철;우선희
    • 약학회지
    • /
    • 제59권4호
    • /
    • pp.158-163
    • /
    • 2015
  • Cardiac myocytes are subjected to fluid shear stress during each contraction and relaxation. Under pathological conditions, such as valve disease, heart failure or hypertension, shear stress in cardiac chamber increases due to high blood volume and pressure. The shear stress induces proarrhythmic longitudinal global $Ca^{2+}$ waves in atrial myocytes. In the present study, we further explored underlying cellular mechanism for the shear stress-induced longitudinal global $Ca^{2+}$ wave in isolated rat atrial myocytes. A shear stress of ${\sim}16dyn/cm^2$ was applied onto entire single myocyte using pressurized fluid puffing. Confocal $Ca^{2+}$ imaging was performed to measure local and global $Ca^{2+}$ signals. Shear stress elicited longitudinally propagating global $Ca^{2+}$ wave (${\sim}80{\mu}m/s$). The occurrence of shear stress-induced atrial $Ca^{2+}$ wave was eliminated by the inhibition of ryanodine receptors (RyRs) or inositol 1,4,5-trisphosphate receptors ($IP_3Rs$). In addition, pretreatment of phospholipase C (PLC) inhibitor U73122, but not its inactive analogue U73343, abolished the generation of longitudinal $Ca^{2+}$ wave under shear stress. Our data suggest that shear-induced longitudinal $Ca^{2+}$ wave may be induced by $Ca^{2+}$-induced $Ca^{2+}$ release through the RyRs which is triggered by $PLC-IP_3R$ signaling in atrial myocytes.

회전식 점도계를 이용한 ERF의 겉보기 점도 특성 (Apparent Viscosity Properties of Electro-Rheological Fluid by Using Rotational Viscometer)

  • 장성철;이진우;김태형;박종근
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.196-201
    • /
    • 2001
  • Electro-Rheological(ER) fluids change their apparent viscosity according to the electric field strength. Therefore, there are many practical applications using the ER fluids. ER effect on the dispersive system of polarizable fine powder/dielectric oil has been investigated. The electrical and rheological properties of starch based ER fluid were reported. Yield stress of the fluids were measured on the couette cell type rheometer as a function of electric fields, particle concetrations, and temperatures. The electric field is applied by high voltage DC power supply, The outer cup is connected to positive electrode(+) and the bob becomes ground(-). And the temperatures the viscosity(or shear stress) versus shear rates were measured. In this experiment shear rates were increased from 0 to 200s$^{-1}$ in 2 minutes. This thesis presents Bingham properties of ER fluids subjected to temperature variations. The temperature dependence of the viscosity was determined for ER fluids consisting of 35 weight % starch particles in automatic transmission oil.

  • PDF