• Title/Summary/Keyword: Fluid flow measuring device

Search Result 23, Processing Time 0.039 seconds

Development of device measuring very high torque via torque arm with attached load cells (로드셀과 토크암을 이용한 대용량 토크 측정장치 개발에 관한 연구)

  • Lee, Y.B.;Han, S.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.1
    • /
    • pp.6-10
    • /
    • 2010
  • A measurement of very high torque for track drive unit in construction equipment is usually in difficulties due to the requirement of a torque meter with high capacity, and the limitation of geometry for an experimental set-up. To improve the troublesome problem, a new device was proposed, where a torque transmitted through the torque arm can be measured by load cells attached at each torque arm. The experimental set-up of the new device was carried out in order to measure the torque values for a mechanical feedback type planetary gear box, in which the power flow circulates itself in a closed-loop. The new device enables to measure torque values of 60,000Nm. Additionally, the measured values were estimated statistically in the aspect of their repeatability and reproducibility, so that an acceptable behaviour as a measuring device can be confirmed.

  • PDF

An experimental study of the time based mass flow controller for semiconductor industry (반도체용 시간식 질량유량계의 특성에 관한 연구)

  • Chang, Young-Chul
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.2
    • /
    • pp.55-58
    • /
    • 2008
  • The objective of the research is to design, manufacture and test a Mass Flow Controller(MFC) capable of measuring compressible fluid flows based on a "bucket and stop-watch"method. The basic principle is the measurement of time, where the time taken to fill and empty a bucket of known volume is measured. This method of flow measurement is a new concept when compared to a commercilized current mass flow controller. For the flow meter to be able to compete with established designs it not only must be comparable in cost and robustness, it must be very accurate and reliable as well. This device should be able to handle fluid flows in the range of 0.1ml/min to 10ml/min within an accuracy of ${\pm}$1%. A possible application for a device such as this is in electronics industry where arsenic gas is used in the production of silicon chips.

  • PDF

Viscosity Measurement in the Capillary Tube Viscometer under Unsteady Flow (비정상유동장에서 모세관점도계의 점도측정)

  • Park, Heung-Jun;Yoo, Sang-Sin;Suh, Sang-Ho
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.825-828
    • /
    • 2000
  • The objective of the present study is to develop a new device that the viscous characteristics of fluids are determined by applying the unsteady flow concept to the traditional capillary tube viscometer. The capillary tube viscometer consists of a small cylindrical reservoir, capillary tube, a load celt system oat measures the mass flow rate, interfacers, and computer. Due to the small size of the reservoir the height of liquid in the reservoir decreases as soon as the liquid in the reservoir drains out through the capillary and the mass flow rate in the capillary decreases as the hydrostatic pressure in the reservoir decreases resulting in a decrease of the shear rate in the capillary tube. The instantaneous shear rate and. driving force in the capillary tube are determined by measuring the mass flow rate through the capillary, and the fluid viscosity is determined from the measured flow rate and the driving force.

  • PDF

An experimental study of Incompressible time based mass flow controller (비압축성 시간식 질량유량계의 특성에 관한 연구)

  • Chang, Young-Chul
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.3
    • /
    • pp.55-58
    • /
    • 2008
  • The objective of this research is to design, manufacture and test a mass flow controller capable of measuring compressible as well as incompressible fluid flows based on a 'bucket and stop-watch' method. The basic principle behind such a system is the measurement of time, where the time taken to fill and empty a bucket of known volume is measured. This device should be able to handle fluid flows in the range of 0.1 ml/min to 10 ml/min within an accuracy of ${\pm}$1%. For the flow meter to be able to compete with established designs, it must be not only comparable in cost and robustness, but also very accurate and reliable as well.

  • PDF

Effect of Dentin Desensitizer on the Hypersensitivity of Teeth with Non-carious Cervical Lesions Subsequent to Ultrasonic Scaling (지각과민처치제가 초음파 스케일링 처리한 비우식성 치경부 병소가 있는 치아의 지각과민증에 주는 영향)

  • Cho, Jae-Hyung;Seok, Soohwang;Lee, Sang-Hyeok;Lim, Bum-Soon
    • Korean Journal of Dental Materials
    • /
    • v.43 no.1
    • /
    • pp.17-28
    • /
    • 2016
  • The aim of this study was to evaluate the changes in dentinal permeability after application of dentin desensitizer on exposed dentin immediately after ultrasonic scaling to teeth with non-carious cervical lesions. Thirty caries-free extracted molars were fixed to slide glasses after horizontally being sectioned at 5 mm below the cemento- enamel junction (CEJ). The prepared specimen was connected to a fluid flow measuring device (nano-Flow), and a V-shaped cavity was formed at the CEJ to imitate the non-carious cervical lesion. After no fluid leakage was confirmed in the connected system with specimen, tooth surface was treated ultrasonic cleaning with piezoelectric ultrasonic scalers until dentinal tubules were exposed. And 6 different desensitizers were applied on exposed dentin. Real-time measurements of dentinal fluid flow were performed during ultrasonic scaling and application of dentin desensitizer. To evaluate the occlusion of exposed dentinal tubules, tooth surface was examined by SEM. Following results were observed. After ultrasonic scaling, more dentinal tubules were exposed on the tooth with non-carious cervical lesions compared to tooth without lesions. The rate of fluid flow measured with nano-Flow system had correlation with the degree of dentin occlusion observed with SEM after application of desensitizers on exposed dentin. Desensitizers with glutaraldehyde and HEMA did not decrease the rate of fluid flow and did not show dentin occlusion. Desensitizers with oxalate showed the limited effects on the rate of fluid flow and dentinal tubule occlusion. Desensitizer with resin monomer showed the significant effect on the rate of fluid flow and dentin occlusion.

Measuring rheological properties using a slotted plate device

  • Kee, Daniel-De;Kim, Young-Dae;Nguyen, Q. Dzuy
    • Korea-Australia Rheology Journal
    • /
    • v.19 no.2
    • /
    • pp.75-80
    • /
    • 2007
  • The slotted plate technique has previously been shown to be a successful method for directly measuring the static yield stress of suspensions. In this study, we further establish the usefulness of the slotted plate device as a rheometer especially at low shear rates, taking advantage of the extremely low speeds of the slotted plate technique. Newtonian fluids, a shear thinning fluid, and yield stress fluids were tested using the slotted plate device and the results were compared with those from a commercial rheometer using different standard flow geometries. The relationship between the stress on the plate and the viscosity for the slotted plate device obtained by dimensional analysis (drag) predicts a linear relationship between the force at the plate and the plate speed, consistent with the experimental data. The slotted plate device can measure viscosities at very low shear rates. The apparent viscosity - shear-rate data obtained from the slotted plate device are complementary to those obtained using a commercial rheometer. That is : the slotted plate can measure viscosity in the shear rate range $10^{-7}<\dot{\gamma}<10^{-3}\;s^{-1}$, while the commercial rheometer measures viscosity at shear rates higher than $10^{-3}\;s^{-1}$.

A Micro-Flow Sensor With Multiple Temperature Sensing Elements for Wide Range Flow Velocity Measurement (다단계 온도 감지막을 가진 고영역 흐름측정용 마이크로 흐름센서)

  • Chung Wan-Young;Kim Tae-Yong;Seo Yong-Su
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.1
    • /
    • pp.85-92
    • /
    • 2006
  • A new silicon micro flow sensor with multiple temperature sensing elements was proposed and fabricated in considering wide range flow velocity measuring device. Thermal mass flow sensor measures the asymmetry of temperature profile around the heater which is modulated by the fluid flow. A micro mass flow sensor was normally composed of a central heater and a pair of temperature sensing elements around it. A new 2-D wide range micro flow sensor structure with three pairs of temperature sensing elements and a central heater was proposed and numerically simulated by Finite Difference Formulation to confirm the feasibility of the wide flow range sensor structure. To confirm the simulation result, the new flow sensor was fabricated on silicon substrate and the basic flow sensing properties of the sensor were measured.

Real-time measurement of dentinal fluid flow during desensitizing agent application (상아질 지각과민 처치제의 적용 중에 일어나는 상아세관액 유동의 실시간 측정)

  • Kim, Sun-Young;Kim, Eun-Joo;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.313-320
    • /
    • 2010
  • Objectives: The aim of this study was to examine changes in the dentinal fluid flow (DFF) during desensitizing agent application and to compare permeability after application among the agents. Materials and Methods: A Class 5 cavity was prepared to exposure cervical dentin on an extracted human premolar which was connected to a sub-nanoliter fluid flow measuring device (NFMD) under 20 cm water pressure. DFF was measured from before application of desensitizing agent (Seal&Protect, SP; SuperSeal, SS; BisBlock, BB; Gluma desensitizer, GL; Bi-Fluoride 12, BF) through application procedure to 5 min after application. Results: DFF rate after each desensitizing agent application was significantly reduced when compared to initial DFF rate before application (p < 0.05). SP showed a greater reduction in DFF rate than GL and BF did (p < 0.05). SS and BB showed a greater reduction in DFF rate than BF did (p < 0.05). Conclusions: Characteristic DFF aspect of each desensitizing agent was shown in NFMD during the application procedure.

The study of three dimentional flow field using defocusing method in micromixer (Defocusing 기법을 이용한 마이크로 믹서내의 3 차원 유동장 측정연구)

  • Kim, Su-Heon;Yoon, Sang-Youl;Kim, Kyung-Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.99-102
    • /
    • 2005
  • This study was conducted for obtaining the optimized data to build the mixer or micro fluid device as measuring the three dimensions flow field in micro mixer. To acquire the rapid diffusion on the region of low Reynolds (Re < 100), the staggered herringbone mixer using chaotic advection was selected in this case. At first, by conducting the numerical analytical virtual experiment using CFD-ACE+, three dimensions flow field in the micro mixer was estimated As this flow field was proven using defocusing particle tracing method, the behavior of micro flow with three dimensional aspects could be analyzed. Numerical analysis and flow pattern in the micro mixer by experimental verification made to be able to analyze the chaotic advection. These can be important sources for building more optimized form. Verifying the information of three dimensional flow structure, these information can be used as the data for developing and improving the $\mu$ -TAS.

  • PDF