• Title/Summary/Keyword: Fluid Management

Search Result 513, Processing Time 0.025 seconds

Evaluation of the mixing and Hydrodynamic Behavior in rapid mixing stage on using Computational Fluid Dynamics (전산유체역학를 이용한 급속혼화공정 교반효과 및 유동 평가)

  • Cho, Youngman;Yoo, Soojeon;Yoo, Pyungjoung;Kim, Daeyoung;Hwangbo, Bonghyeong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.799-810
    • /
    • 2009
  • With time, the stable management of turbidity is becoming more important in the water treatment process. So optimization of coagulation is important for the improvement of the sedimentation efficiency. we evaluated the mixing and hydrodynamic behavior in the coagulation basin using Computational Fluid Dynamics (CFD). The items for evaluation are a location and the speed of agitator and angle of an injection pipe. The results of the CFD simulation, the efficacy of mixing in the coagulation basin was not affected according to one or two injection pipe and angle of an injection pipe. If there is a agitator near outlet of coagulation basin, the efficacy of mixing don't improve even though the speed of agitator increase. So location of agitator is perfect when it locate center at the inlet stream. The coagulation basin at this study, the proper speed of agitator is form 20rpm to 30rpm.

Real-time line control system for automated robotic assembly line for multi-PCB models

  • Park, Jong-Oh;Hyun, Kwang-Ik;Um, Doo-Gan;Kim, Byoung-Doo;Cho, Sung-Jong;Park, In-Gyu;Kim, Young-Sik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1915-1919
    • /
    • 1991
  • The efficiency of automated assembly line is increased by realizing the automation of each assembly cell, monitoring the line information and developing the real-time line control system it. which production flow is controllable. In this paper, the several modules which are important factors when constructing automated real-time control system, such as, line control S/W module, real-time model change module, error handling module and line production management S/W module, are developed. For developing these important programming modules, real-time control and multi-tasking techniques are integrated. In this paper, operating method of real-time line control in PCB automated assembly line is proposed and for effective control of production line by using multi-tasking technique, proper operating method for relating real-time line control with multi-tasking is proposed by defining the levels of signals and tasks. CIM-Oriented modular programming method considering expandability and flexibility will be added for further research in the future.

  • PDF

Analysis of Drainage Efficiency of Different Type of Drainage using Computational Fluid Dynamic Method (유동해석을 통한 배수지형태에 따른 배수효율분석)

  • Cho, Jung-Yeon;Go, Sun-Ho;Kim, Hong-Gun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.2
    • /
    • pp.34-43
    • /
    • 2017
  • Large amounts of household water are required as common households change from the single-residence types of the past to group-residence types. Therefore, the management of reservoirs is urgently required to ensure the supply of clean household water to users. Important considerations for household water include the duration for which the water is stored in the reservoir, the disinfectant's dilution capacity, and the size of the reservoir to allow for the amount of water required for emergencies and firefighting. The drainage efficiency was analyzed in this study using computational fluid analysis for existing rectangular reservoirs and the newly proposed hexagonal reservoir. Thus, it was determined that the centrifugal force generated at the inlet was maintained until the outlet due to the approximately circular shape of the hexagonal reservoir. The findings of this study verified that the centrifugal force improved the flow rate by approximately 35% compared to existing rectangular reservoirs and that drainage was performed efficiently without stagnation zone.

A method to prevent cerebrospinal fluid leakage: Reinforcing acellular dermal matrix

  • Lee, Hojune;Eom, Ye Seul;Pyon, Jai-Kyong
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.1
    • /
    • pp.45-48
    • /
    • 2020
  • In neurosurgical cases, problems related to wound healing can vary from simple wound dehiscence to multilayer defects. This study demonstrates an effective method to prevent persistent cerebrospinal fluid (CSF) leakage using reinforcing acellular dermal matrix in neurosurgical patients with wound dehiscence. A 52-year-old woman was admitted for management of recurrent glioblastoma. After tumor removal surgery, the patient experienced sustained CSF leakage from the wound despite reparative attempts. The plastic surgery team performed wound repair procedure after remnant tumor removal by the neurosurgery team. Acellular dermal matrix was applied over the mesh plate to prevent CSF leakage and the postoperative status of the patient was evaluated. No sign of CSF leakage was found in the immediate postoperative period. After 3 years, there were no complications including CSF leakage, wound dehiscence, and infection. We hereby propose this method as a feasible therapeutic alternative for preventing CSF leakage in patients experiencing wound problem after neurosurgical procedures.

Analysis of land-based circular aquaculture tank flow field using computational fluid dynamics (CFD) simulation (전산 유체 역학(CFD)을 이용한 원형 양식 사육 수조 내부 유동장 해석)

  • KWON, Inyeong;KIM, Taeho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.56 no.4
    • /
    • pp.395-406
    • /
    • 2020
  • The objectives of this study were to develop the optimal structures of recirculating aquaculture tank for improving the removal efficiency of solid materials and maintaining water quality conditions. Flow analysis was performed using the CFD (computational fluid dynamics) method to understand the hydrodynamic characteristics of the circular tank according to the angle of inclination in the tank bottom (0°, 1.5° and 3°), circulating water inflow method (underwater, horizontal nozzle, vertical nozzle and combination nozzle) and the number of inlets. As the angle in tank bottom increased, the vortex inside the tank decreased, resulting in a constant flow. In the case of the vertical nozzle type, the eddy flow in the tank was greatly improved. The vertical nozzle type showed excellent flow such as constant flow velocity distribution and uniform streamline. The combination nozzle type also showed an internal spiral flow, but the vortex reduction effect was less than the vertical nozzle type. As the number of inlets in the tank increased, problems such as speed reduction were compensated, resulting in uniform fluid flow.

A Ballooning Phenomenon of Torque Converter Torus Size for Automatic Transmissions (자동변속기용 토크컨버터 토러스 사이즈에 따른 팽창 현상)

  • Jang, Jaeduk;Lee, Woongcheol;Sung, Dukhwan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.6
    • /
    • pp.702-708
    • /
    • 2016
  • The torque converter is deformed according to the rotating speed and control pressure when engine power is transferred to the transmission. This deformation, which is called ballooning phenomenon, occurs mainly at the outer side by the centrifugal force of the automatic transmission fluid (ATF) and the control pressure from the valve body. Although the torque converter is slightly deformed when rotating, the ballooning phenomenon affects fluid performance, efficiency and durability. Thus, expansion characteristics analysis is important in determining torus size, control pressure and structure. In this paper, an analysis equation and FEM model was developed to investigate the expansion characteristics. Using this model, structural analysis was performed to investigate the relationships between deformation and the torus diameter. The results were confirmed by comparing with the test results.

An Integrated Numerical Analysis Framework for Engineering Education in e-Science Environment (e-사이언스 환경에서 공학 교육을 위한 통합 수치 해석 프레임워크)

  • Park, Sook-Young;Kang, Hye-Jeong;Kim, Yoon-Hee
    • The Journal of Korean Association of Computer Education
    • /
    • v.15 no.2
    • /
    • pp.67-73
    • /
    • 2012
  • The analytical experiments for fluid dynamics lead a sequence of complex scientific computations composing of numerical equations and require enormous computing resources with appropriate management tools. Currently most studies on e-Science environment for numerical studies focus on solving specific problems to drag out the best performance of matters and have less interest in providing a common framework to apply for diverse numerical domains in engineering education, especially for fluid dynamics. This paper presents an integrated e-Science experiment tool which could be easily applicable to solve various numerical analyses in fluid dynamics. As a proof-of-concept, an integrated e-Science framework with three numerical analyses has been designed and implemented over UNICORE that runs over grid computing environment.

  • PDF

Validation of Synovial Fluid Clinical Samples for Molecular Detection of Pathogens Causing Prosthetic Joint Infection Using GAPDH Housekeeping Gene as Internal Control

  • Jiyoung Lee;Eunyoung Baek;Hyesun Ahn;Youngnam Park;Geehyuk Kim;Sua Lim;Suchan Lee;Sunghyun Kim
    • Biomedical Science Letters
    • /
    • v.29 no.4
    • /
    • pp.220-230
    • /
    • 2023
  • Identification of the pathogens causing infection is important in terms of patient's health management and infection control. Synovial fluids could be used as clinical samples to detect causative pathogens of prosthetic joint infections (PJIs) using molecular diagnostic assays, therefore, normalization and validation of clinical samples are necessary. Microbial culture is considered the gold standard for all infections, including PJIs. Recently, molecular diagnostic methods have been developed to overcome the limitation of microbial culture. Therefore, guideline for validating clinical samples to provide reliable results of molecular diagnostic assays for infectious diseases is required in clinical field. The present study aimed to develop an accurate validating method of synovial fluid clinical samples using GAPDH gene as an internal control to perform the quantitative PCR TaqMan probe assay to detect pathogens causing PJIs.

The Role of Chest CT Scans in the Management of Empyema (농흉에서 전산화 단층촬영의 의의)

  • Heo, Jeong-Suk;Kwun, Oh-Yong;Sohn, Jeong-Ho;Choi, Won-Il;Hwang, Jae-Seok;Han, Seung-Beom;Jeon, Young-June;Kim, Jung-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.4
    • /
    • pp.397-404
    • /
    • 1994
  • Background: To decide the optimal antibiotics and application of chest tube, examination of pleural fluid is fundamental in the management of empyema. Some criteria for drainage of pleural fluid have been recommended but some controversies have been suggested. Recently, newer radiologic methods including ultrasound and computed tomography scanning, have been applied to the diagnosis and management of pleural effusions. We undertook a retrospective analysis of 30 patients with pleural effusion who had CT scans of the chest in order to apply the criteria of Light et al retrospectively to patients with loculation and to correlate the radiologic appearance of pleural effusions with pleural fluid chemistry. Method: We analyzed the records of 30 out of 147 patients with pleural effusion undergoing chest CT scans. Results: 1) Six of the pleural fluid cultures yielded gram negative organisms and three anaerobic bacterias and one Staphylococcus aureus and one non-hemolytic Streptococci. No organism was cultured in ninteen cases(63.0%). 2) The reasons for taking chest CT scans were to rule out malignancy or parenchymal lung disease(46.7%), poor response to antibiotics(40.0%), hard to aspirate pleural fluid(10.0%) and to decide the site for chest tube insertion(3.3%). 3) There was no significant correlations between ATS stages and loculation but there was a tendency to loculate in stage III. 4) There was a significant inverse relationship between the level of pH and loculation(p<0.05) but there appeared to be no relationship between pleural fluid, LDH, glucose, protein, loculation and pleural thickening. 5) In 12 out of 30, therapeutic measures were changed according to the chest CT scan findings. Conclusion: We were unable to identify any correlations between the plerual fluid chemistry, ATS stages and loculations except pH, and we suggest that tube thoracotomy should be individualized according to the clinical judgement and serial observation. All patients with empyema do not need a chest CT scan but a CT scan can provide determination of loculation, guiding and assessing therapy which should decrease morbidity and hospital stay.

  • PDF

Numerical Analysis of Heat Transfer and Solidification in the Continuous Casting Process of Metallic Uranium Rod (금속 우라늄봉의 연속주조공정에 대한 열전달 및 응고해석)

  • Lee, Ju-Chan;Lee, Yoon-Sang;Oh, Seung-Chul;Shin, Young-Joon
    • Journal of Korea Foundry Society
    • /
    • v.20 no.2
    • /
    • pp.80-88
    • /
    • 2000
  • Continuous casting equipment was designed to cast the metallic uranium rods, and a thermal analysis was carried out to calculate the temperature and solidification profiles. Fluid flow and heat transfer analysis model including the effects of phase change was used to simulate the continuous casting process by finite volume method. In the design of continuous casting equipment, the casting speed, pouring temperature and cooling conditions should be considered as significant factors. In this study, the effects of casting speed, pouring temperature, and air gap between the uranium and mold were investigate. The results represented that the temperature and solidification profiles of continuous casting equipment varied with the casting speed, pouring temperature, and air gap.

  • PDF