• 제목/요약/키워드: Flue-gas

검색결과 606건 처리시간 0.024초

Numerical Study on NO Emission with Flue Gas Dilution in Air and Fuel Sides

  • Cho Eun-Seong;Chung Suk Ho
    • Journal of Mechanical Science and Technology
    • /
    • 제19권6호
    • /
    • pp.1358-1365
    • /
    • 2005
  • Flue gas recirculation (FGR) is widely adopted to control NO emission in combustion systems. Recirculated flue gas decreases flame temperature and reaction rate, resulting in the decrease in thermal NO production. Recently, it has been demonstrated that the recirculated flue gas in fuel stream, that is, the fuel induced recirculation (FIR), could enhance much improved reduction in NO per unit mass of recirculated gas, as compared to conventional FGR in air. In the present study, the effect of dilution methods in air and fuel sides on NO reduction has been investigated numerically by using $N_2$ and $CO_2$ as diluent gases to simulate flue gases. Counterflow diffusion flames were studied in conjunction with the laminar flamelet model of turbulent flames. Results showed that $CO_2$ dilution was more effective in NO reduction because of large temperature drop due to the larger specific heat of $CO_2$ compared to $N_2$. Fuel dilution was more effective in reducing NO emission than air dilution when the same recirculation ratio of dilution gas was used by the increase in the nozzle exit velocity, thereby the stretch rate, with dilution gas added to fuel side.

90kW급 우드칩 온수 보일러 특성 및 성능 시험 (Measurement of Efficiency and Flue Gas Concentration of 90 kW Woodchip Boiler)

  • 강새별;김종진;최규성;이웅진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.194-197
    • /
    • 2008
  • We measured the efficiency and flue gas concentration of a 90kW woodchip boiler which is for heating water of lodging. At nominal operating condition, the fuel, woodchip is fed into the boiler at a rate of 22.6 kg/h. In order to determine the efficiency of the boiler, we measured the water flow rate, woodchip flow rate, heating value and water content of woodchip, temperature of inlet and outlet of heating water. The results of test show that the power output of the woodchip boiler is 90.0 kW(77,400 kcal/h) and the thermal efficiency of the boiler is 88.5%. By using a gas analyser, flue gas concentrations are measured. The results show that O2 in the flue gas is 10.2%, CO concentration is 393 ppm and NOx concentration is 74 ppm.

  • PDF

양방향 펄스 전원에 의한 배기가스의 제거 (The Removal of Flue Gas by Using Bidirectional Pulse Generator)

  • 전재룡;성기범;고광철;강형부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2224-2226
    • /
    • 1999
  • Non-thermal plasma techniques is applied in many fields. Recently acid rain, global warming, ozone depletion, and smog are preeminent environmental problems. The cause for this environmental problems is the flue gas. Non-thermal plasma techniques has an attention for the solution of flue gas. Non-thermal plasma is used for the removal of flue gas composed of NOx, etc. This field has grown dramatically. This experiment is performed by using cylinder type reactor under the condition of room temperature and atmosphere pressure. NO gas is used instead of flue gas. Bidirectional pulse generator is used instead of the unidirectional pulse generator to increase the efficiency.

  • PDF

습증기를 포함한 연소가스의 폐열회수를 위한 열교환기 성능 예측 (Performance Prediction of Heat Exchanger for Waste Heat Recovery from Humid Flue Gases)

  • 정동운;이상용;이한주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.276-281
    • /
    • 2000
  • A simulation program using the mass transfer correlation was constructed to analyze 1-D simplified condensing flow across the tube bank. Higher efficiency was anticipated by reducing the flue gas temperature down below the dew point where the water vapor in the flue gas is condensed at the surface of the heat exchanger; that is, the heat transfer by the latent heat is added to that by the sensible heat. Thus, there can be an optimum operating condition to maximize the heat recovery from the flue gas. The temperature rises of the flue gas and the cooling water between the inlet and the outlet of the tube bank were compared with the experimental data reported previously. The predicted results agree well with the experimental data. Using this simulation program, the parametric studies have been conducted fur various operating conditions, such as the velocities and temperatures of the vapor/gas mixture and the cooling water, the number of the rows, and the conductivity of the wall material.

  • PDF

KIER의 NOx 및 연소배가스 처리기술 개발현황 (R&D Status of NOx and Flue-gas Treatment Technologies in KIER)

  • 민병무;최상일
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 제26회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.295-300
    • /
    • 2003
  • In Korea, the emission standards for air pollutants will be more tighten from Jan. 2005. Especially, the new emission standards is focused on the nitrogen oxide. From this trend of standards, nitrogen oxide emission is hot issue in energy fields. Also, we have a new environmental problem, the carbon dioxide emission, which are related to the global warming. To solve the environmental problems, we must define the situation of clean-up technologies level in Korea and decide the direction of R&D for flue gas cleaning technologies. Now, this paper discus briefly on the De-NOx R&D activities and the large scale testing facility for flue gas clean-up technologies in Korea Institute of Energy Research. These discussions are contribute to the increasing of the R&D activities for flue gas clean-up technologies in Korea.

  • PDF

흡착/촉매 공정개선을 위한 사이클론 내 유동특성 및 활성탄 체류시간 산정 (Flow Characteristics and Residence Time of Activated Carbon in the Cyclone for Optimized Design of an Adsorption/Catalysis Reactor)

  • 최청렬
    • 대한기계학회논문집B
    • /
    • 제31권5호
    • /
    • pp.416-424
    • /
    • 2007
  • In adsorption/catalytic process, numerical analysis has been performed to identify the flow characteristics of flue gas in the cyclone and to estimate the residence time of activated carbon using Computational Fluid Dynamics (CFD) technique. To consider flue gas and activated carbon particles simultaneously, Euler-Lagrangian model was employed so that residence time could be obtained from the numerical analysis directly. The numerical analysis has been performed with different three particle sizes and compared each flow characteristics with particle’ size. Fundamental flow patterns of flue gas and activated carbon particles, pressure distribution, residence time of flue gas, and activated carbon particles and distribution of activated carbon have been obtained from the numerical analysis.

Two-dimension Numerical Simulation of Stack Flue Gas Dispersion

  • Park, Young-Koo;Wu, Shi-Chang
    • 한국응용과학기술학회지
    • /
    • 제29권1호
    • /
    • pp.33-39
    • /
    • 2012
  • A numerical simulation of plume from a stack into atmospheric cross flow is investigated using a two-dimension model. The simulation is based on the ${\kappa}{\sim}{\varepsilon}$ turbulence model and a finite volume method. In this paper, it mostly researches how the wind velocity affects the flue gas diffusion from an 80 m high stack. Wind velocity is one of the most important factors for flue gas diffusion. The plume shape size, the injection height, the NO pollutant distribution and the concentration at the near ground are presented with two kinds of wind velocities, 1 m/s and 5 m/s. It is found that large wind velocity is better for flue gas diffusion, it generates less downwash. Although the rise height is lower, the pollutant dilutes faster and more sufficient.

$Co_{2}$ Fixation by Chlorella KR-1 Using Flue Gas and its Utilization as a Feedstuff for Chicks

  • Lee, Jin-Suk;Kim, Deog-Keun;Lee, Joon-Pyo;Park, Soon-Chul;Koh, Jong-Ho;Ohh, Sang-Jip
    • Journal of Microbiology and Biotechnology
    • /
    • 제11권5호
    • /
    • pp.772-775
    • /
    • 2001
  • A highly $CO_2$ tolerant microalga, Chlorella KR-1, has been isolated and used to fix $CO_2$ from actual flue gas. Growth of Chlorella KR-1 with the supply of flue gas from a liquified natural gas boiler was comparable to that obtained with 10% $CO_2$. Chlorella KR-1 produced from $CO_2$ fixation using the flue has about 50% crude protein with balanced amino acid profiles. Toxicity was not detected when the microalga was used as a feedstuff for chicks. These results indicate that the KR-1 cells could be a favorable protein source for poultry.

  • PDF

소각기의 배기가스 유로에 이젝터를 적용한 시스템의 성능 분석 (Performance Analysis on the Ejector System in Flue-gas Discharge Channel of Marine Incinerator)

  • 윤상국;장호길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권6호
    • /
    • pp.773-778
    • /
    • 2011
  • 선박용 소각기는 각종 폐기물의 연소로 인한 해양환경 오염 우려로 국제해사기구에 의한 기준이 점점 강화되어지고 있다. 본 연구는 배기가스의 온도를 낮추고 연소실의 연소가스가 원활하게 배출되도록 배기가스의 배출 유로를 3개로 하고, 배기통로 내에 보조 이젝터를 설치한 시스템의 성능 향상에 대하여 Ansys를 사용하여 유동 해석을 수행하였다. 해석결과, 배기가스 유로의 다채널화에 의하여 배기가스 온도가 국제해사기구 기준보다 낮게 유지되었으며, 통로에 설치한 보조 이젝터가 배기가스 배출에 매우 효과적인 장치인 것으로 분석되었다.

백필터를 활용한 흡착/촉매 통합공정 시스템의 반응기 내 유동특성 및 체류시간에 대한 수치해석적 연구 (Numerical Analysis on Flow Characteristics in the Reactor of an Integrated Adsorption/Catalysis Process with Bag Filters)

  • 최청렬;구윤서
    • 한국대기환경학회지
    • /
    • 제23권2호
    • /
    • pp.203-213
    • /
    • 2007
  • Numerical analysis has been performed to understand flow characteristics in the reactor with bag filters in an integrated adsorption/catalytic process which can treat dioxin and $NO_{x}$ together. Computational fluid dynamics technique was employed with Euler-Lagrangian model to consider flue gas and activated carbon particles simultaneously, so that residence time of flue gas and activated carbon particle could be obtained from the numerical analysis directly. The numerical analysis has been performed with different three particle sizes and compared each flow characteristics with particle's size. Fundamental flow patterns of flue gas and activated carbon particles, pressure distribution, residence time of flue gas and activated carbon particles, and distribution of activated carbon have been obtained from the numerical analysis. Flow patterns of flue gas and activated carbon particles in the reactor were very complicated and they moved along very various paths. Therefore, their residence time in the reactor was also various. The results obtained would be effectively used to estimate the removal efficiency in the reactor once the residence time is combined with the reaction equation.