• 제목/요약/키워드: Flue-gas

검색결과 607건 처리시간 0.026초

100 MWe 순산소 석탄연소 발전시스템의 개념설계-영동 프로젝트 (Conceptual Design of 100 MWe Oxy-coal Power Plant-Youngdong Project)

  • 최상민
    • 한국연소학회지
    • /
    • 제17권3호
    • /
    • pp.30-45
    • /
    • 2012
  • An existing unit of power plant is considered to refurbish it for possible application of carbon capture and storage(CCS). Conceptual design of the plant includes basic considerations on the national and international situation of energy use, environmental concerns, required budget, and time schedule as well as the engineering concept of the plant. While major equipment of the recently upgraded power plant is going to be reused, a new boiler for air-oxy fired dual mode operation is to be designed. Cryogenic air separation unit is considered for optimized capacity, and combustion system accommodates flue gas recirculation with multiple cleaning and humidity removal units. The flue gas is purified for carbon dioxide separation and treatment. This paper presents the background of the project, participants, and industrial background. Proposed concept of the plant operation is discussed for the possible considerations on the engineering designs.

산업 보일러용 오일버너에서의 저 NOx 연소 연구 (A Study on Low-NOx Combustion in an Oil Burner for an Industrial Boiler)

  • 신명철;김세원;박주원;방병열;양원;고영건
    • 한국연소학회지
    • /
    • 제14권1호
    • /
    • pp.19-24
    • /
    • 2009
  • A novel low NOx oil burner of 0.7 MW (for a 1 ton steam/hr industrial boiler) was designed and tested to investigate the combustion characteristics through in-flame measurement and flue gas analysis. Flame shape was observed by CCD camera and $CH^*/{C_2}^*$ radical distribution in the flame were observed, along with measurement of flue gas composition such as NOx and CO, for various heat inputs, excess airs and pressure of the fuel spary nozzles. The flame showed the two-zone structure: fuel-rich and fuel-lean zone, which was very favorable for the low-NOx combustion, and the NOx emission for haevy oil combustion was significantly reduced to < 150 ppm at 4 % $O_2$, compared with the NOx level of a conventional heavy oil burner.

  • PDF

진동연소기의 NOx 저감 효과 연구 (NOx Reduction Study in Oscillating Combustion Burner)

  • 강상구;;김기성
    • 한국연소학회지
    • /
    • 제12권4호
    • /
    • pp.22-30
    • /
    • 2007
  • The NOx emission characteristics were studied in an oscillating combustion burner equipped with a specially designed proportioning valve. The effects of various parameters on the NOx emission which are important in oscillating combustion were investigated. Also, the effects of coincident application of flue gas recirculation(FGR) were evaluated. The results show that oscillating combustion is an efficient tool for reducing NOx in the burner. Up to 53% of NOx reduction could be acquired in low frequency and small duty ratio conditions. The coincident application of FGR further reduced the NOx emission up to 74%. Thus, this study assured that oscillating combustion technology with FGR could be a fascinating method for NOx reduction in industrial burners.

  • PDF

$CaCo_3-CO_2-NH_3$계에서의 배연탈황 특성 (Characteristics of the Flue Gas Desulfurization in $CaCo_3-CO_2-NH_3$ System)

  • 모세영;이경재;장홍기;손종렬
    • 환경위생공학
    • /
    • 제14권2호
    • /
    • pp.84-89
    • /
    • 1999
  • This experiment was performed to develop the new desulfurization process which can eliminate the possibility of generation of the secondary pollutants by regenerating the limestone from the sulfite/sulfate slurry generated from the wet lime/limestone flue gas desulfurization process by treating it with the ammonium hydroxide and carbon dioxide and using it again. In the experiments, regent grade calcium carbonate was dissolved to obtain the 200ml of sample slurry of the concentration of 2.0~0.4 weight percent. After three times of regeneration and desulfurization process, the coefficients of regeneration and desulfurization efficiencies are calculated/measured. The obtained results are that the coefficients of generation of the first. second, and third regenerated calcium carbonate were 90.88, 92.13, and 91.50%, respectively; and the desulfurization efficiencies of those are 93.4, 94.2 and 93.0%, respectively.

  • PDF

폐기물 소각시 중금속 성분의 거동에 관한 연구 (A Study on Behavior of Heavy Metals during Waste Incineration)

  • 박용이;허철구
    • 한국환경과학회지
    • /
    • 제5권6호
    • /
    • pp.785-799
    • /
    • 1996
  • The incineration tests of mixed industrial wastes using the stoker type incinerator are carried out to investigate the partitioning characteristics of heavy metals during incineration. The results obtained from this study are as follow. The partitioning characteristics of heavy metals throughout this incinerator are found that, at given condition of $700^{\circ}C$, the elements with the relatively high boiling point such as Cr, Cu and Pb are partitioned into a bottom ash, a fry ash captured tv cyclone, and a flue gas stream, 67~88%, 2~19% and 6~16% of initial amount entering the incinerator, respectively, but the Cd and Hg of 75~81% is vaporized into the flue gas. It appears that the partitioning characteristics according to the particle size of ash is different between the bottom ash and the fly ash. For bottom ash, the fraction of partitioning into 75${\mu}{\textrm}{m}$ oversized particles is reatively high. For fly ash, the characteristics of distributions with the particle size can not be clearly shown.

  • PDF

구리 분말을 이용한 $SO_2$ 배기가스의 처리(I) (The Treatment of Flue SO$_2$ Gas by Cu Powder (I))

  • 정국삼;김학성;신창섭
    • 한국안전학회지
    • /
    • 제1권1호
    • /
    • pp.27-32
    • /
    • 1986
  • To remove sulfur dioxide from flue gas by the method of metal oxide, copper powder of average diameter $2.4\mu\textrm{m}$and $51\mu\textrm{m}$ were used in a fixed bed reactor over a, temperature range of $300^{\circ}C-500^{\circ}C$. Copper oxide reacts with sulfur dioxide producing cupric sulfate and it can be regenerated from the latter by using hydrogen or methane. Experimental results showed that the reaction rate was increased by the increase of reaction temperature in the range of $300^{\circ}C-422^{\circ}C$ and the removal efficiency of sulfur dioxide was high in case of small size copper particle. However the removal efficiency was decreased at higher temperature due to decomposition of cupric sulfate. The rate controlling step of this reaction was chemical reaction and deactivating catalysts model can be applied to this reaction. The rate constants for this reaction and deactivation are as follows : k=8,367exp(-10,298/RT) Kd=2.23exp(-8,485/RT)

  • PDF

산소부화화염의 희석방법에 따른 화염특성 변화 (Variation of oxygen-enriched flame characteristics with dilution method)

  • 한지웅;이창언
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.332-337
    • /
    • 2003
  • Oxygen-enriched non-premixed flame characteristics was investigated numerically with variation of dilution methods, which are Flue gas recirculation(FGR) and fuel injection recirculation(FIR). In order to compare flamelets in various oxygen-enrichment conditions reasonably, the adiabatic flame temperature and Damkoller number was held fixed by modulating amount of diluents to fuel and oxidizer stream and by varying global strain rate of flame respectively. Also modified GRI 3.0 reaction mechanism was utilized, which was able to predict oxygen-enriched methane flame correctly. Fundamental flame characteristics such as structure, heat release rate and extinction with FGR and FIR were compared in various oxygen enrichment conditions.

  • PDF

열교환기에서의 유동유발 진동 저감 (Reduction of Flow-Induced Vibration in the Heat Exchanger)

  • 장한기;김승한;이재현;양정렬
    • 소음진동
    • /
    • 제9권6호
    • /
    • pp.1200-1209
    • /
    • 1999
  • This paper reports a peculiar example of flow-induced vibration in a very large plant and the whole procedure of reducing the vibration. During the operation of flue gas desurfurization unit of the thermal power plant, serious vibration was dtected at all around the plant. The worst vibration was recorded on the heat exchanger surface, which weighed 180 tones, as 17.8 m/$s^2$ in vibration amplitude at 34 Hz. To identify the vibration, frequency analysis on the response vibration as well as on the expected excitation forces and the system resonance was executed. This investigation revealed that the cause of the vibration was vortex shedding from the circular pipes in the heat exchanger. Vortices from the pipes excited acoustic resonance in the heat exchanger room, which, in turn, made the structure vibrate. Through inserting the baffles between the pipes, which had an effect of cutting the acoustic wave at resonance frequency, the vibration was eliminated dramatically.

  • PDF

기포분사반응기를 사용한 배연탈황공정의 아황산가스 물질전달 (Mass Transfer of Sulfur Dioxide in Flue Gas Desulfurization Process Utilizing a Jet Bubbling Scrubber)

  • 동종인;나진균;홍지형
    • 한국대기환경학회지
    • /
    • 제8권4호
    • /
    • pp.262-268
    • /
    • 1992
  • The trend of international concerns on environmental conservation and domestic demand of ambient air quality improvement, specially on sulfur dioxide level has resulted in the establishment of mid-term strategy of environmental improvement and stepwise strengthening of emission regulations in this decade in Korea. Development of flue gas desulfurization(FGD) process is becoming an essential task to be accomplished especially for the power plants and large industrial facilities. This study is an initial stage researc focusing on the mass transfer principles in wet type FGD process and the effects of operating variables of a jet bubbling scrubber utilizing limestone slurry on sulfur dioxide removal efficiency. Experimental results showed this type of scrubbing system has some advantages in terms of mass transfer mechanism and removal efficiency. More rigorous research is needed for the reaction system and the comparison with existing FGD processess for the possible development of a process which is compatative in view of installation cost and treatment of by-products.

  • PDF

부극성 직류 코로나 방전에 미치는 자계의 영향 (Effect of Magnetic Field on Negative DC Corona Discharge)

  • 박재윤;김익균;정장근;김건호;김정달;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2308-2310
    • /
    • 1999
  • The effect of magnetic field on NOx removal characteristics from a combustion flue gas has been experimentally investigated for a DC corona discharge reactor with a multipoint plate geometry in our Lab. Combustion flue gas removal efficiency of this type was much higher than that of the other types. In this paper, needle-plate geometry discharge system with applied magnetic field at a right angle to the electric field was made. Input power source was used negative DC. The corona discharge characteristics for this system was investigated and compared with the corona characteristics for the corona discharge system without magnetic field.

  • PDF