• Title/Summary/Keyword: Flowable composite

Search Result 106, Processing Time 0.031 seconds

A STUDY ON PHYSICAL PROPERTIES OF FLOWABLE COMPOSITE RESINS (유동성 복합레진의 물리적 성질에 대한 연구)

  • Kim, Ji-Young;Jeong, Byung-Cho;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.423-429
    • /
    • 2002
  • Recently, the clinical uses of flowable composite resins have increased because of fast, convenient and excellent accessibility, but little has been reported about physical properties of flowable resins. The purpose of this study was to measure and compare the physical properties(compressive strength, relative flowability, relative radiopacity) of 4 contemporary flowable composite resins(Filtek flow, Tetric Flow, Revolution Palfique Estelite LV high flow). The results were as follows; 1. There were no significant differences between 4 flowable composite resins in compressive strength, but all were lower than that of traditional hybrid composite resin(p<0.001). 2. The relative flowability were increased in order of Palfique Estelite LV high flow, Revolution, Filtek flow, Tetric Flow and sealant(p<0.001), but there were no significant differences between Filtek flow and Tetric Flow. 3. There were significant differences between flowable composite resins in relative radiopacity and they showed similar or higher radiopacity than dentin(p<0.001), especially Tetric Flow and Filtek Flow showed higher radiopacity than enamel(p<0.001). This results suggested that the stress of application area have to be considered since flowable composite resins have lower compressive strength than hybrid composite, and the differences of flowability between these flowable composite resins can be considered when they are selected. All tested flowable composite resins showed optimal radiopacity to ISO's recommend.

  • PDF

A COMPARATIVE STUDY BETWEEN DEGREE OF CONVERSION AND FLEXURAL STRENGTH OF COMPOSITE RESINS

  • Lee Seong-Hee;Pae Ahran;Kim Sung-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.333-342
    • /
    • 2006
  • Statement of problem. Although many studies have been carried out to investigate the correlation between the degree of conversion and the flexural strength of composite resins, there is minimal information in the literature attempting to compare degree of conversion, flexural strength and their correlation between restorative composite resins and flowable composite resins. Purpose. The purposes of this study were to measure the degree of conversion and flexural strength of composite resins with different rheological behavior and to correlate the two properties. Materials and methods. Four restorative (Vit-1-escence, Z-250, Tetric ceram, Esthet-X) and four flowable (Aeliteflo, Admiraflow, Permaflo, Revolution) light-curing composite resins were investigated. The degree of conversion(DC) was analyzed with Fourier transfer infra-red spectroscopy(FTIR) spectrum by a potassium bromide(KBr) pellet transmission method. The spectrum of the unpolymerized specimen had been measured before the specimen was irradiated for 60s with a visible light curing unit. The Poiymerized specimen was scanned for its in spectrum. The flexural strength(FS) was measured with 3-point bending test according to ISO 4049 after storage in water at $37^{\circ}C$ for 24 hours. The data were statistically analyzed by an independent sample t-test and one-way ANOVA at the significance level of 0.05. The dependence of flexural strength on the degree of conversion was also analyzed by regression analysis. Results. Mean DC and FS values ranged from 43% to 61% and from 84.7MPa to 156.7MPa respectively. DC values of the flowable composite resins were significantly higher than those of restorative composite resins (P < 0.05). The FS values of restorative composite resins were greater than those of flowable composite resins. No statistically significant correlation was observed between the DC and the FS tested in any of the composites. The dependence of FS on DC in restorative or flowable composite resins was not significant. Conclusion. It can be concluded that radical polymerization of the organic matrix is not a major factor in determining flexural strength of the commercially available composite resins.

Effect of flowable resin composite on bond strength to wedge shaped cavity walls.

  • Ogata, M.;Pereira, PNR.;Harada, N.;Nakajima, M.;Nikaida, T.;Tagami, J.
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.558.1-558
    • /
    • 2001
  • Flowable resin composite is a relatively new restorative material. It has been reported that a low viscosity, low modulus intermediate resin applied between the bonding agent and restorative resin act as an "elastic buffer" that can relieve contraction stress. This in-vitro study aimed to evaluate the effect of flowable composite resin as a restorative material on regional tensile bond stredgth to cervical wedge shaped cavity walls. (omitted)

  • PDF

Survival Rates of Class II Restoration in Primary Molar with Flowable Resin Composite (유동성 복합레진을 이용한 유구치 II급 수복의 생존율)

  • Seo, Hyejun;Park, Soyoung;Lee, Eungyung;Jeong, Taesung;Shin, Jonghyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.12-20
    • /
    • 2021
  • The purpose of this retrospective study was to evaluate the survival rate by comparing Class II restoration using flowable resin composite with stainless steel crown in primary molars. Electronic medical records and radiographs of 1,504 primary molars with proximal caries of 590 patients from June 2015 to August 2019 were analyzed. With the collected data, survival analysis was performed using the Kaplan-Meier method. The 1-year survival rate of flowable resin composite in the primary molar was 98.5%, 3-year survival rate was 87.7%, and mean survival time was 39 months. There was no statistically significant difference between flowable resin composite and stainless steel crown (p = 0.896). Within the limits of this study, Class II restoration using flowable resin composite can be considered a promising option for the treatment of proximal caries in primary molars.

Retentive strength of different intracanal posts in restorations of anterior primary teeth: an in vitro study

  • Memarpour, Mahtab;Shafiei, Fereshteh;Abbaszadeh, Maryam
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.4
    • /
    • pp.215-221
    • /
    • 2013
  • Objectives: To determine the retentive strength and failure mode of undercut composite post, glass fiber post and polyethylene fiber post luted with flowable composite resin and resin-cement. Materials and Methods: Coronal parts of 120 primary canine teeth were sectioned and specimens were treated endodontically. The teeth were randomly divided into 6 groups (n = 20). Prepared root canals received intracanal retainers with a short composite post, undercut composite post, glass fiber post luted with flowable resin or resin-cement, and polyethylene fiber post luted with flowable resin or resin-cement. After crown reconstruction, samples were tested for retentive strength and failure mode. Statistical analysis was done with one-way ANOVA and Tukey tests (p < 0.05). Results: There were statistically significant differences between groups (p = 0.001). Mean bond strength in the undercut group was significantly greater than in the short composite post (p = 0.030), and the glass fiber post (p = 0.001) and the polyethylene fiber post group luted with resin-cement (p = 0.008). However, the differences between the undercut group and the groups with flowable composite as the luting agent were not significant (p = 0.068, p = 0.557). Adhesive failure was more frequent in the fiber post groups. Conclusions: Although the composite post with undercutting showed the greatest resistance to dislodgement, fiber posts cemented with flowable composite resin provided acceptable results in terms of retentive strength and fracture mode.

Microleakage of posterior packable composite resin at the gingival margins of class II cavities

  • Choi, Su-Jin;Kwon, Hyuk-Choon
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.585.1-585
    • /
    • 2001
  • The use of flowable composite resins as liners in class II packable composite resins has been suggested by some manufacturers. However, the contributions of this technique are unproven. Objectives: The aim of this study was to compare the gingival microleakage in class II packable composite restorations with or without the use of flowable composite resins as liners.. Method: Slot cavities were prepared on both proximals of 80 extracted human molars and randomly assigned to 8 groups of 20 each.(중략)

  • PDF

Comparison of microleakage after load cycling for nanofilled composite resin fillings with or without flowable resin lining (Nanofilled 복합레진으로 와동 충전 시 flowable 레진 사용 유무에 따른 피로시험 후의 미세 변연 누출 비교)

  • Han, Sun-Deok;Kim, Won;Choi, Ji-Young;Oh, Nam-Sik;Lee, Myung-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.342-347
    • /
    • 2009
  • Statement of problem: when using resin for class II restoration, micoleakage by instrumentation can be regarded as the primary negative characteristic. A review of the available literature suggests that using flowable resin as liner to decreased microleakage. Purpose: The aim of this study was to determine the influence of the nanofilled flowable resin lining on marginal microleakage after load cycling in class II composite restoration fillings using nanofiller resin. Material and methods: 24 extracted premolars were prepared with class II cavity. F group was restored the nanofilled resin with the nanofilled flowable resin as liner. NF group was restored the nanofilled resin only. After restoration, an experiment was performed on 2 groups using a 300N load at 104, 105 and 106 cycles. Prior to and before each load cycling, it was gauged length on total marginal microleakage, axial marginal microleakage and buccal, gingival, lingual marginal microleakage. Data were analyzed with the Mann-Whitney test & Kruskal-Wallis test. Results: There were statistically significant differences between 2 groups and between individual groups. (P <.05) The result showed less microleakage in teeth restored by the nanofilled resin, which was lined by the nanofilled flowable resin. Conclusion: There was significant reduction in microleakage when the nanofilled flowable resin lining was placed underneath the nanofilled resin in class II composite restoration fillings.

The influence of flowable composite lining in Class II composite restoration

  • Lee, Jung-Min;Park, Jeong-Won;Kim, Sung-Kyo
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.575-575
    • /
    • 2001
  • The purpose of this study is to investigate the influence of flowable composite lining on microleakage at gingival dentin margin in Class II composite restoration. Sixty extracted human molars were prepared as box-only Class II form on the mesial and distal surfaces. The prepared cavities were randomly assigned to six groups.(omitted)

  • PDF

Effect of dentin roughening and type of composite material on the restoration of non-carious cervical lesions: an in vivo study with 18 months of follow-up

  • Sanjana Verma;Rakesh Singla;Gurdeep Singh Gill;Namita Jain
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.4
    • /
    • pp.35.1-35.14
    • /
    • 2023
  • Objectives: The purpose of this study was to evaluate the impact of dentin roughening and the type of composite resin used (either bulk-fill flowable or nanohybrid) on the restoration of non-carious cervical lesions (NCCLs) with an 18-month follow-up period. Materials and Methods: This prospective split-mouth study included 36 patients, each with a minimum of 4 NCCLs. For each patient, 4 types of restorations were performed: unroughened dentin with nanohybrid composite, unroughened dentin with bulk-fill flowable composite, roughened dentin with nanohybrid composite, and roughened dentin with bulk-fill flowable composite. A universal bonding agent (Tetric N Bond Universal) was applied in self-etch mode for all groups. The restorations were subsequently evaluated at 6, 12, and 18 months in accordance with the criteria set by the FDI World Dental Federation. Inferential statistics were computed using the Friedman test, with the level of statistical significance established at 0.05. Results: The 4 groups exhibited no significant differences in relation to fracture and retention, marginal staining, marginal adaptation, postoperative hypersensitivity, or the recurrence of caries at any follow-up point. Conclusions: Within the limitations of the present study, over an 18-month follow-up period, no significant difference was present in the clinical performance of bulk-fill flowable and nanohybrid composite restorations of non-carious cervical lesions. This held true regardless of whether dentin roughening was performed.

Polymerization Shrinkage and Stress of Silorane-based Dental Restorative Composite (Silorane-기질 치아 수복용 복합레진의 중합수축과 중합수축응력)

  • Lee, In-Bog;Park, Sung-Hwan;Kweon, Hyun-Jeong;Gu, Ja-Uk;Choi, Nak-Sam
    • Composites Research
    • /
    • v.26 no.3
    • /
    • pp.182-188
    • /
    • 2013
  • The purpose of this study was to measure the volumetric polymerization shrinkage kinetics and stress of a silorane-based dental restorative composite and compare it with those of conventional methacrylate-based dental composites. Two methacrylate-based composites (Z250, Z350 flowable) and one silorane-based composite (P90) were investigated. The volumetric polymerization shrinkage of the composites during light curing was measured using a laboratory-made volume shrinkage measurement instrument based on the Archimedes' principle, and the polymerization stress was also determined with the strain gage method. The shrinkage of silorane-based composites (P90) was the lowest, and that of Z350 flowable was the highest. Peak polymerization shrinkage rate was the lowest in P90 and the highest in Z350 flowable. The time to reach peak shrinkage rate of P90 was longer than those of the methacrylate-based composites. The polymerization shrinkage stress of P90 was lower than those of the methacrylate-based composites.