• Title/Summary/Keyword: Flow-supply Characteristics

Search Result 449, Processing Time 0.025 seconds

Experimental Study on the Water Hammer Absorption Effects of Water Hammer Arrester in the Water Supply Piping System (급수관로계에 설치된 수격흡수기의 수격흡수효과에 관한 실험적 연구)

  • Choi, Jung-Geun;Lee, Suk-Jong;Lee, Myoeng-Ho;Sung, Jae-Yong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.3
    • /
    • pp.396-402
    • /
    • 2006
  • In this study, dynamic characteristics of water hammer pressure in water supply piping system with water hammer arrester has been investigated experimentally to characterize the transient pressure of water hammer in high rise building. Experiments were conducted to verify the absorption effects by water hammer arresters with 3 different gas volumes of water hammer pressure generated by sudden valve closure. As the results, it has been found that zoning and sizing of pipe diameter for suitable flow velocity and water hammer arresters with effective pressure absorption capacity have to be installed to protect water hammer problems in building water supply piping system.

Power Flow Analysis of Railroad System Using Supply Network Method (급전회로망 해석기법을 활용한 고속전철 조류해석 기법)

  • Yun, Jae-Yeong;Choe, Heung-Gwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.12
    • /
    • pp.602-607
    • /
    • 2000
  • This paper presents the new simulation algorithms using network methods to analysis the steady-state train voltage distribution characteristics in ac auto-transformer fed railroads. In general, the supply system of railroads is composed of non-symmetrical and unbalance transmission line. Therefore, the general method using simplified old algorithms have the self-contradictory errors because the supply line of train railroads is completely unbalanced. In this paper, the simulation results of new developed algorithms is compared with those of EMTP to confirm the effectiveness.

  • PDF

Cold Flow and Ignition Tests for Technology Demonstration Model of 75-Tonf Thrust Chamber (75톤급 연소기 기술검증 시제 수류시험 및 점화시험)

  • Kim, Mun-Ki;Han, Yeoung-Min;Kim, Jong-Gyu;Ahn, Kyu-Bok;Lee, Kwang-Jin;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.97-100
    • /
    • 2009
  • Cold flow and ignition tests were performed for a technology demonstration model of a 75-tonf thrust chamber which is a candidate liquid rocket engine for a next Korea Space Launch Vehicle. The test facility was modified to support the new concepts of the thrust chamber such as ignition system, film cooling and LOx leading supply. The hydrodynamic characteristics of the supply pipelines, thrust chamber and igniter as well as the filling time of the propellants were obtained through the cold flow tests on the LOx and kerosene and the ignition cyclogram was determined using the results. The ignition test was successfully accomplished according to the cyclogram and therefore, a basic information was obtained for further hot firing tests.

  • PDF

Performance Characteristics of a Main Oxidizer Shutoff Valve for Liquid Rocket Engines (액체로켓엔진용 연소기 산화제 개폐밸브 성능 특성)

  • Jeong, Daeseong;Hong, Moongeun;Han, Sangyeop
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.4
    • /
    • pp.28-35
    • /
    • 2017
  • A main oxidizer shutoff valve controls the supply of the oxidizer flow into the combustion chamber of a liquid rocket engine. This shutoff valve also carries out the pre-chilling of oxidizer supply lines by permitting recycling flow for stable transient start of the engine. In the present paper, the flow tests for the recycling line of the valve were conducted in order to evaluate the cooling performance of the main oxidizer shutoff valve. In addition, cryogenic life-cycle tests were performed with an assumption of the increase of spring constant with increasing valve operating times due to ductile-brittle transition effects.

Numerical Simulation on Smoke Movement in Multi-Compartment Enclosure Fires under Pressurized Air Supply Conditions (급기가압 조건에서 복합 구획 공간 화재의 연기 거동에 대한 수치해석 연구)

  • Ko, Gwon Hyun
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.15-21
    • /
    • 2018
  • This study examined the flow characteristics of fire smoke under pressurized air ventilation conditions by carrying out fire simulations on multi-compartment enclosure, including room, ancillary room and stair case. Fire simulations were conducted for the air-leakage test facility, which was constructed to measure the effective leakage area and aimed to improve the understandings of fire and smoke movement by analyzing the overall behaviors of fire smoke flow and pressure distributions of each compartment. The simulation results showed that the heat release rate of the fires was controlled sensitively by the amount of air supplied by the ventilation system. An analysis of the velocity distributions between the room and ancillary room showed that fire smoke could be leaked to the ancillary room through the upper layer of the door, even under pressurized air supply conditions. From these results, it was confirmed that the fire size and spatial characteristics should be considered for the design and application of a smoke control system by a pressurized air supply.

Numerical analysis on effect of hole size on Emergency Evacuation Support System (수치해석을 통한 비상피난지원 시스템의 급기구 크기에 따른 유동분석)

  • Kim, Ji Tae;Park, Won Hee;Lee, Duck Hee;Ro, Kyoung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.324-329
    • /
    • 2020
  • The emergency evacuation support system provides a safe means of evacuation by preventing the inflow of smoke through the formation of a smoke shield curtain in fire situations and pressurizing fresh air to the inside of the smoke shield curtain. In this study, numerical analysis was performed to examine the effects of the hole size on the flow inside the smoke curtain. As the air supply size decreased, the flow rate through the air supply was formed relatively uniformly from the inlet to the outlet length of the emergency support system. In addition, the size of the air supply hole was more than 20 mm, the flow rate was very low near the outlet, so the air supply hole size should be smaller than 20 mm. In addition, the minor loss of the air supply hole was calculated to be K = 1.5 from the numerical results. Therefore, the proper design of an emergency evacuation support system is possible using the flow characteristics according to the size and minor loss of the air supply hole.

The Characteristics of Current Distribution and Electrical Insulation on High-Tc Superconducting Cable (고온 초전도 케이블의 전류 분포 및 전기절연 특성)

  • ;;;;Takataro Hamajima
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.6
    • /
    • pp.271-277
    • /
    • 2003
  • It is important to control layer current distributions of coaxial multi-layer HTS cables, because a homogeneous layer current distribution decreases AC loss and can supply the largest operational current. We have extended the theory that treat the operational current more than the critical current by considering V-I nonlinear characteristics of HTS tapes including flux flow resistance and contacting resistance between the cable and terminals. It is important to investigate the current distribution under the condition of operational current more than the critical current of cable, because the cable has experiences of fault current. In order to verify the extended theory, we have fabricated a two layers cable with the same twisting layer pitch. It was observed that almost all the operational current less than the critical current flowed on the outer layer because of its lower inductance. In case of operational current more than critical currents of layers, the flux flow resistances affect strongly current waveform and thereby the currents of layers were determined by the flux flow resistances. And we investigated breakdown characteristics in $LN_{2}$/paper composite insulation system for the application to a HTS cable. In this experiment, we got some information out of that the electrical characteristics of the insulation materials depends on the condition of butt gap.

Flow Analysis around within Sump in a Pump Station using by the CFD (CFD에 의한 펌프장 Sump내 유동해석)

  • Roh, Hyung-Woon;Kim, Jae-Soo;Suh, Sang-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.89-94
    • /
    • 2002
  • n general, the function of intake structure, whether it be a open channel, a fully wetted tunnel, a sump or a tank, is to supply an evenly distributed flow to a pump station. An even distribution of flow, characterized by strong local flow, can result in formation of surface or submerged vortices, and with certain low values of submergence, may introduce air into pump, causing a reduction of capacity and efficiency, an increase in vibration and additional noise. Uneven flow distribution can also increase or decrease the power consumption with a change in total developed head. To avoid these sump problems pump station designers are considered intake structure dimensions, such as approaching upstream, baffle size, sump width, width of pump cell and so on. From this background, flow characteristics of intake within sump are investigated numerically to obtain the optimal sump design data. The sump model is designed in accordance with HI code.

  • PDF

Harmonic Generation and System Response Characteristics in Electrified Railway(I) - Focused on System Response Characteristics - (전기철도에서의 고조파 발생과 계통응답특성(I) - 계통응답특성을 중심으로 -)

  • Oh Kwang-Hae;Lee Chang-Mu
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.493-498
    • /
    • 2003
  • Harmonic current originating from electric locomotives can be magnified due to the impedance characteristics of power supply circuit and bring about various problems. That is, electromagnetic interference with communication lines, operational trouble in signaling, overheat and/or vibration in power capacitor, mis-operation in protection relay and so on. Therefore, the exact assessment of the harmonic current flow must be undertaken at design and planning stage for the electric traction systems. For these reasons, this study propose a new approach to model and to analyse traction power feeding system focused on system response to current and voltage harmonic(PART I ). Measurements of harmonics are also performed for railway power supply systems under normal operation. Spectrum and distortion analyses in measurement data are variously described in PART II

  • PDF

Harmonic Generation and System Response Characteristics in Electrified Railway(I) - Focused on System Response Characteristics - (전기철도에서의 고조파 발생과 계통응답특성(I) - 계통응답특성을 중심으로 -)

  • 오광해;이장무
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.1
    • /
    • pp.60-64
    • /
    • 2004
  • Harmonic current originating from electric locomotives can be magnified due to the impedance characteristics of power supply circuit and bring about various problems. That is, electromagnetic interference with communication lines, operational trouble in signaling, overheat and/or vibration in power capacitor, mis-operation in protection relay and so on. Therefore, the exact assessment of the harmonic current flow must be undertaken at design and planning stage for the electric traction systems. for these reasons, this study propose a new approach to model and to analyse traction power feeding system focused on system response to current and voltage harmonic(PART I). Measurements of harmonics are also performed for railway power supply systems under normal operation. Spectrum and distortion analyses in measurement data are variously described in PART II.