CFD에 의한 펌프장 Sump내 유동해석

Flow Analysis around within Sump in a Pump Station using by the CFD

  • 노형운 (조선대학교 항공우주공학과) ;
  • 김재수 (조선대학교 항공우주공학과) ;
  • 서상호 (숭실대학교 기계공학과)
  • 발행 : 2002.12.01

초록

n general, the function of intake structure, whether it be a open channel, a fully wetted tunnel, a sump or a tank, is to supply an evenly distributed flow to a pump station. An even distribution of flow, characterized by strong local flow, can result in formation of surface or submerged vortices, and with certain low values of submergence, may introduce air into pump, causing a reduction of capacity and efficiency, an increase in vibration and additional noise. Uneven flow distribution can also increase or decrease the power consumption with a change in total developed head. To avoid these sump problems pump station designers are considered intake structure dimensions, such as approaching upstream, baffle size, sump width, width of pump cell and so on. From this background, flow characteristics of intake within sump are investigated numerically to obtain the optimal sump design data. The sump model is designed in accordance with HI code.

키워드