• Title/Summary/Keyword: Flow-supply Characteristics

Search Result 449, Processing Time 0.023 seconds

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

A Study on the Characteristics Using Pig Manure Under Aerobic Air Flow Rate During Composting (돈분이용 퇴비화과정에서의 공기공급량별 퇴비화 특성변화에 관한 연구)

  • Kwag, J.H.;Kim, J.H.;Jeong, K.H.;Cho, S.H.;Ahn, H.K.;Choi, D.Y.;Jeong, M.S.;Lee, S.C.;Kang, H.S.;Ra, C.S.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.2
    • /
    • pp.131-138
    • /
    • 2011
  • This study was carried out to investigate on the composting characteristics variation accoding to air supply capacity in Pig manure. The composting of pig manure is economical and efficiently process. The fermented compost was added in pig manure mixed with sawdust was composting reators. Air supply capacity levels of fermented compost on the pig manure mixed with sawdust were regulated at 50, 100, 150 and 200$\ell/m^3$/min. respectively. The obtained results can be followed as bellow; The temperature variations of experimental composting piles during composting for the different of T-1 reach $40^{\circ}C$ in 2 days, T-2, T-3 and T-4 reach $60^{\circ}C$ in 2 days and T-3, T-4 maintained until 8 days. The decreases in water contents per each square meter for the different of T-1 (50 l/$m^3$/min), T-2(100 l/$m^3$/min), T-3(150 l/$m^3$/min) and T-4(200 l/$m^3$/min.), The decreases ratio in water contents was T-1, T-2, T-3 and T-4 were 15.4%, 28.8%, 33.4% and 35.2%. The decreases ratio in weight was T-1, T-2, T-3 and T-4 were 7.6%, 15.6%, 16.8% and 16.9% respectively. The variations of oxygen concentration from composting period in case of oxygen discharge concentration T-1, T-2, T-3 and T-4 were 9 ppm. respectively. Fertilizer components after composting were examined. Nitrogen contents of the T-1, T-2, T-3 and T-4 were 0.45%, 0.44%, 0.42% and 0.44%, and P2O5 contents were T-1, T-2, T-3 and T-4 were 0.37%, 0.41%, 0.42% and 0.44% respectively. Therefore, the compost curing air supply of air volumes at least 150$\ell$/min/min. or more to supply the aerobic composting pig manure normally are judged to be possible.

Characterization of Toluene Vapor Removal Efficiency Using Alnus Firma Fruit in a Biological Treatment Process (오리나무 열매를 이용한 생물처리장치에서의 톨루엔 가스 처리효율 특성)

  • 공남식;차수길;서정윤
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.6
    • /
    • pp.689-699
    • /
    • 2003
  • This study was to examine characteristics of treating toluene vapor, which gets to be problematic due to its harmful carcinogenicity and mass generation from various sources, through a biological treatment facility which is environment-friendly and adopts a high-efficient and low-cost clean technology. In order to identify whether Alnus Firma Fruit (AFF) can be used as a media for a bioreactor, its utility and basic operating factors, a study was conducted on pressure drop, supply of nutrient substances and retention time which are operating factors of a biofilter, and eliminating characteristics were compared between AFF and the conventional biological activatedcarbon (BAC) widely used as filter media. In the case of AFF, the initial microbial deposits was 2.3${\times}$10$^{7}$ CFU/g dry AFF, which represents the initial microbial density higher than the case of BAC showing 5.5${\times}$10$^{6}$ CFU/g dry BAC And it took about 2 weeks to acclimate until its eliminating rate got to be increased over 90%. As a result of comparing pressure loss taking place with the lapse of time between BAC and AFF, after 130 days passed at SV 25h$^{-1}$ , BAC showed that its eliminating efficiency had a tendency to drop greatly due to a great pressure loss (0.53\longrightarrow54.7 mm$H_2O$/m) caused by an excess of biomass as accumulated. On the other hand. AFF showed that the pressure drop was 0.53 mm$H_2O$/m, about 2 times as much as the initial pressure loss of 0.4 mm$H_2O$/m, which represents no great change in the pressure loss, and its eliminating efficiency was also shown to be continuously high. Therefore, when AFF was used as a filler for a biological treatment facility, a biological filter enabling improvement of the purifying efficiency to be promoted could be provided, and moreover, the pressure loss was so small that the filler replacement cycle or the back flushing cycle could be extended. So, even in terms of the operating cost, it was identified to be an economical filler When an inorganic material was used as a filler, the biofilters performance acted sensitively on whether nutrient substances were supplied or not. In the case of AFF with low adsorptivity, addition of ethyl-alcohol increased the solubility of toluene, and consequently, biodegradation got to be actively made by microbes, and thus, its eliminating rate could be increased. As the flow velocity and the inflow concentration got to be more increased, its eliminating rate got to be lower, and particularly, an increase in the flow velocity made its eliminating rate drop more greatly than an increase in the concentration.

Experimental Feasibility Study on Low-Temperature Differential Stirling Engines with Water Spray Heat Transfer (스프레이 열전달을 이용한 저온도차 스털링 엔진의 실험적 개념 연구)

  • Jang, Seon-Jun;Lee, Yoon-Pyo;Sim, Kyuho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.6
    • /
    • pp.475-482
    • /
    • 2014
  • This paper presents the results of an experimental feasibility study on low-temperature differential Stirling engines with water spray heat transfer. The water spray enhances the efficiency of the heat transfer from heat sources to the engine and reduces the performance degeneration due to the dead volumes of conventional heat exchangers. A test Stirling engine was developed and an experiment was conducted to determine the characteristics for the initial start-up, steady-state operation, and power output for various flow rates and temperatures of hot supply water. The test results showed that larger flow rates led to reductions in the minimum working temperature of the hot water at start-up. During a series of steady-state operations, higher flow rates and temperatures increased the working speed. Furthermore, the work per cycle and power output were also increased. Eventually, the test Stirling engine had a power level of 0.05 W. Based on this, further research will be conducted to obtain a higher power output and investigate various applications.

Numerical Simulation of Salinity Intrusion into Groundwater Near Estuary Barrage with Using OpenGeoSys (OpenGeoSys를 이용한 하굿둑 인근 지하수 내 염분 침투 수치모의)

  • Hyun Jung Lee;Seung Oh Lee;Seung Jin Maeng
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.4
    • /
    • pp.157-164
    • /
    • 2023
  • The estuary dam is a structure installed and operated in a closed state except when flood event occurs to prevent inland saltwater intrusion and secure freshwater supply. However, the closed state of dam leads to issues such as eutrophication, so it is necessary to examine the extent of saltwater intrusion resulting from the opening of sluice gates. Groundwater, due to its subsurface conditions and slow flow characteristics, is widely analyzed using numerical models. OpenGeoSys, an open-source software capable of simulating Thermal- Hydraulic- Mechanical- Chemical phenomena, was adopted for this study. Simulations were conducted assuming natural flow conditions without dam and operating considering busy farming season, mostly from March to September. Verification of the model through analytical solutions showed error of 3.7%, confirming that OpenGeoSys is capable of simulating saltwater intrusion for these cases. From results simulated for 10 years, considering for the busy farming season, resulted in about 46% reduction in saltwater intrusion length compared to natural flow conditions, approximately 74.36 m. It may be helpful to make choices to use groundwater as a water resource.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

Developmental Characteristics and Weathering Processes of Tafoni at Golgulsa Temple, Gyeongju, South Korea (경주 골굴사 타포니의 발달 특성과 풍화 과정)

  • Shin, Jae Ryul;Choo, Chang Oh;Lee, Jin Kook;Park, Kyung Geun
    • Journal of the Korean association of regional geographers
    • /
    • v.23 no.1
    • /
    • pp.168-177
    • /
    • 2017
  • In order to reveal formation factors and developmental processes of tafoni this study was conducted with petrological analysis including microscopic observation, measurement of water content and water analysis at Golgulsa temple in Gyeongju, South Korea. The direction of the entrance to tafoni at Golgulsa temple tends to coincide with the direction of slope, and this is thought to be related to the direction of wind flow and water supply. Tafoni's initial developmental processes is judged to have grown as a result of a breakaway of rock fragments along with beddings and cracks in rock. Then, tafoni have been enlarged along at the spots that sufficiently accommodate water supply depending on the direction of wind. The results of water analysis of the stagnant water in gnamma implies that a high meltage of Na and Cl compared to other inland areas can be from the adjacent shore. The effects of such saline substances on rock weathering and development of taponi are currently under way through electronic microscopy and geochemical analysis.

  • PDF

The experimental study on the emission characteristics of the coal gas in the condition of high pressure combustion (석탄가스 고압연소시 배기가스 배출특성에 관한 실험적 연구)

  • Hong, Sung Joo;Lee, Min Chul;Kim, Ki Tae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.134-134
    • /
    • 2010
  • Recently, the interest of the study about IGCC(Integrated Gasification Combined Cycle), one of New & Renewable Energy technologies, bas been increased due to the United Nations Framework Convention on Climate Change, the Low Carbon Green Growth policy, etc. Also, with this interest of IGCC, the study on the gas turbine utilizing the synthetic gas is performing actively. In the study of the gas turbine characteristic, the power performance and the combustion efficiency are mainly discussed and also the concern about the exhaust gas is being taken care of due to the increasing awareness of the environment. With this, we would like to go over the exhaust gas emission characteristic by the synthetic gas inflow in this test. In order to conduct such a test, we constructed a synthetic gas supplying system to supply the synthetic gases ($H_2$: hydrogen, $N_2$: nitrogen, CO: carbon monoxide, $CO_2$: carbon dioxide, and $H_2O$: steam) quantitatively and this combustion test was conducted by controlling the supplied synthetic gases artificially. The concentration of the exhaust gases appeared variously depending on the differences of the inflow nitrogen amount and the steam amount, whether or not the carbon dioxide flow in and so on. The results of the test can be able to be utilized for the IGCC study by understanding the exhaust gas emission characteristic of the coal gas turbine by synthetic gas composition.

  • PDF

Operating Characteristics of 0.4 MW-Scale Gas Dispersion Type FGD Absorber (0.4 MW급 가스분사식 배연탈황 흡수탑의 운전 특성)

  • An, Hi-Soo;Kim, Ki-Hyoung;Park, Seung-Soo;Park, Kwang-Kyu;Kim, Young-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.4
    • /
    • pp.415-422
    • /
    • 2008
  • This study was carried out to investigate the effect of operating and design conditions of gas dispersion type of absorber on $SO_2$ removal efficiency. pH difference between upper and lower part of gas dispersing plate of absorber was 0.2, which was relatively low. This was supposed that recirculation capacity of absorbing liquid between froth zone and reaction zone of absorber be increased by oxidation air injection through liquid riser which acted as liquid pump. Test results showed that $SO_2$ removal efficiency was more sensitive than absorber ${\Delta}P$. High $SO_2$ removal even at lower pH resulted from very low concentration of $HSO_3^-$ ion in absorbing liquid because of direct supply of dissolved oxygen into froth zone. 96% of $SO_2$ removal efficiency was obtained under the condition of absorber pH 5.2, flue gas flow rate of $1,530\;Nm^3/hr$, inlet $SO_2$ concentration of 800 ppm, absorber ${\Delta}P$ of 250mmAq. The following equation by a multiple linear regression was obtained to describe the relationship between $SO_2$ removal and operating variables. $$f=1-{\exp}(-1.3939+1.060pH+0.0139{\Delta}P-0.00267G-0.000064SO_2Conc.),\;R^2=0.9719$$

Comparison of Combustion Characteristic with GN2O and GOX as Oxidizer in Hybrid Rocket (하이브리드 로켓의 산화제 종류에 따른 고체연료 연소특성 비교)

  • Lee, Jung-Pyo;Cho, Sung-Bong;Kim, Soo-Jong;Yoon, Sang-Kyu;Park, Su-Hayng;Kim, Jin-Kon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.223-227
    • /
    • 2006
  • In this study, the combustion characteristics was studied with various oxidizer in hybrid propulsion system. In this experiments $GN_2O$ and GOX were used as oxidizer, and PE was used as fuel. The combustion behavior was explained by flame temperature with mass O/F ratio, and the use of $GN_2O$ as the oxidizer caused a increase in combustion efficiency with GOX in the same hybrid motor. The mass flow rate of gaseous oxidizer was controlled by the several chocked orifices that have different diameter, and the oxidizer supply range was $0.0138{\sim}0.0427kg/sec$. As result, the empirical relation for oxidizer type was represented by mass flux of solid fuel, it was obtained with mass transfer number, and mass flux of oxidizer.

  • PDF