• 제목/요약/키워드: Flow-Rate

검색결과 12,712건 처리시간 0.049초

공기의 온도-엔트로피 선도 상에서 13 종류의 물성치 작도 (Plotting of 13 Kinds of Properties on Temperature-Entropy Chart of Air)

  • 김덕진;김덕봉
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1191-1196
    • /
    • 2009
  • The T-s chart of air displays graphically the thermophysical properties, so it is very conveniently used in various thermal systems. In previous study, the software analyzing 31 kinds of values in water system and 32 kinds of values in air-conditioning system were developed. In this study, the software drawing 13 kinds of quantity of state on air properties as ideal gas and analyzing 25 kinds of values in any air system was developed. The 13 kinds of quantity of state on air properties are temperature, pressure, specific volume, specific internal energy, specific enthalpy, specific entropy, specific exergy, exergy ratio, density, isobaric specific heat, isochoric specific heat, ratio of specific heat, and velocity of sound, and the 25 kinds of values including 13 kinds are mass flow rate, volume flow rate, internal energy flow rate, enthalpy flow rate, entropy flow rate, exergy flow rate, heat flow rate, power output, power efficiency, reversible work, lost work, and relative humidity. The developed software can draw any range of chart and analysis any state or process on air system. Also, this supports various document-editing functions such as power point. We wish to this chart is a help to design, analysis, and education in air system field.

  • PDF

물의 T-s 선도 상에서 26 종류의 물성치 작도 및 시스템 해석 프로그램 개발 (Program Development for Drawing of 26 Properties and System Analysis on T-s Diagram of Water or Vapor)

  • 김덕진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.157-164
    • /
    • 2008
  • The temperature-entropy diagram of water or vapor displays graphically the thermophysical properties, so it is very conveniently used in various thermal systems. On general T-s chart of water, there are temperature, pressure, quality, specific volume, specific enthalpy, specific entropy. However, various state and process values besides above properties can be plotted on T-s diagram. In this study, we developed the software drawing twenty six kinds of properties, that is temperature, pressure, quality, specific volume, specific internal energy, specific enthalpy, specific entropy, specific exergy, exergy ratio, density, isobaric specific heat, isochoric specific heat, ratio of specific heat, coefficient of viscosity, kinematic coefficient of viscosity, thermal conductivity, prandtl number, ion product, static dielectric constant, isentropic exponent, velocity of sound, joule-thomson coefficient, pressure coefficient, volumetric coefficient of expansion, isentropic compressibility, and isothermal compressibility. Also, this software can analyze and print the system values of mass flow rate, volume flow rate, internal energy flow rate, enthalpy flow rate, entropy flow rate, exergy flow rate, heat flow rate, power output, power efficiency, and reversible work. Additionally, this software support the functions such as MS-Power Point.

  • PDF

수소 유량에 따른 IZO 박막의 구조적 및 전기적 특성 (Structural and Electrical Characteristics of IZO Thin Films Deposited at Different Hydrogen Flow Rate)

  • 홍경림;이규만
    • 반도체디스플레이기술학회지
    • /
    • 제18권3호
    • /
    • pp.7-11
    • /
    • 2019
  • We have investigated the effect of the hydrogen flow rate on the characteristics of IZO thin films for the TCO (transparent conducting oxide). For this purpose, IZO thin films are deposited by RF magnetron sputtering at 300℃ with various H2 flow rate. To investigate the influences of the ambient gases, the flow rate of hydrogen in argon was varied from 0.1 sccm to 1 sccm. The IZO thin films deposited at 300℃ show crystalline structure having an (222) preferential orientation. The electrical resistivity of the crystalline-IZO films deposited at 300℃ and hydrogen gas of 0.8sccm was 3.192×10-4Ω cm, the lowest value. As the hydrogen gas flow rate increased, the resistivity tended to decrease. The XPS profiles showed that the number of oxygen vacancy decreased as the hydrogen flow rate increased. The transmittance of the IZO films deposited at 300℃ were showed more than 80%.

Semi-batch Jet Loop Reactor에서 연소 배가스중 CO2를 이용한 알칼리 폐수 중화 (Neutralization of Synthetic Alkaline Wastewater with CO2 in a Semi-batch Jet Loop Reactor)

  • 손민기;성호진;이제근
    • 한국연소학회지
    • /
    • 제18권2호
    • /
    • pp.17-22
    • /
    • 2013
  • In this study, we tested the absorption of $CO_2$ in combustion gas into an alkaline wastewater to simultaneously control $CO_2$ and wastewater. During the experiment, we investigated the effects of operating parameters on neutralization characteristics of the wastewater by using $CO_2$ in a bench-scale semi-batch jet loop reactor (0.1 m diameter and 1.0 m in height). The operating parameters investigated in the study are gas flow rate of 1.0-2.0 L/min, liquid recirculation flow rate of 4-32 L/min, and liquid temperature of $20-25^{\circ}C$. It was shown that the initial pH of wastewater rapidly decreased with increased gas flow rate for a given liquid recirculation flow rate. This was due to the increase in the gas holdup and the interfacial area at higher gas flow rate in the reactor. At constant gas flow rate, the time required to neutralize the wastewater initial pH of 10.1 decreased with liquid recirculation flow rate ($Q_L$), reached a minimum value in the range of $Q_L$ = 16-24 L/min, and then increased with further increase in $Q_L$. Further, the time required to neutralize the wastewater was shortened at higher temperatures.

Semi-batch Jet Loop Reactor에서 연소 배가스중 CO2를 이용한 알칼리 폐수 중화 (Neutralization of Synthetic Alkaline Wastewater with CO2 in a Semi-batch Jet Loop Reactor)

  • 손민기;성호진;이제근
    • 한국연소학회지
    • /
    • 제18권3호
    • /
    • pp.38-43
    • /
    • 2013
  • In this study, we tested the absorption of $CO_2$ in combustion gas into an alkaline wastewater to simultaneously control $CO_2$ and wastewater. During the experiment, we investigated the effects of operating parameters on neutralization characteristics of the wastewater by using $CO_2$ in a bench-scale semi-batch jet loop reactor (0.1 m diameter and 1.0 m in height). The operating parameters investigated in the study are gas flow rate of 1.0-2.0 L/min, liquid recirculation flow rate of 4-32 L/min, and liquid temperature of $20-25^{\circ}C$. It was shown that the initial pH of wastewater rapidly decreased with increased gas flow rate for a given liquid recirculation flow rate. This was due to the increase in the gas holdup and the interfacial area at higher gas flow rate in the reactor. At constant gas flow rate, the time required to neutralize the wastewater initial pH of 10.1 decreased with liquid recirculation flow rate ($Q_L$), reached a minimum value in the range of $Q_L$ = 16-24 L/min, and then increased with further increase in $Q_L$. Further, the time required to neutralize the wastewater was shortened at higher temperatures.

하나로 비상 보충수 공급계통의 노심 주입 냉각유량 해석 (THE ANALYTIC ANALYSIS OF THE CORE INJECTION COOLING FLOW RATE FOR EMERGENCY WATER SUPPLY SYSTEM IN HANARO)

  • 박용철;김봉수;김경연;우종섭
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 추계 학술대회논문집
    • /
    • pp.39-44
    • /
    • 2005
  • In HANARO, a multi-purpose research reactor of 30 MWth, the emergency water supply system consists essentially of an emergency water storage tank located in the level of about thirteen meter (13 m) above the reactor core, a three inch ('3\%') diameter water injection pipe line including injection valves from the tank to the reactor cooling inlet pipe and a test loop to do periodic system performance test. When the water level of the reactor pool comes down to the extremely low due to a loss of reactor pool water accident the emergency water stored in the tank should be fed to the core by the gravity force and at that time the design flow rate is eleven point four kilogram per second (11.4 kg/s). But it is impossible periodically to measure the injection flow rate under the emergency condition because the normal water level should be maintained during the reactor operation. This paper describes a flow network analysis to simulate the flow rate under the emergency condition. As results, it was confirmed through the analysis results that the calculated flow rate agrees with the design requirement under the emergency condition.

  • PDF

압력섭동에 의한 유량변동 측정 정량화 (Quantifying the Variation of Mass Flow Rate generated by Pressure Fluctuation)

  • 길태옥;김동준;조성호;안규복;한영민;윤영빈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.152-156
    • /
    • 2007
  • 로켓 엔진에서 연소챔버 내의 압력섭동에 의해 발생되는 추진제 유량변동에 대한 현상을 파악하는 것은 매우 중요하다. 이를 위해 압력섭동이 발생되었을 때 유량변동의 측정에 대한 정량화를 수행하였다. 오리피스 내의 유동의 속도를 알기 위해 오리피스 내의 압력을 측정한 후 이론식에 입각하여 속도를 풀었고, 액막두에 측정장치를 이용하여 오리피스 내에서의 면적을 측정하였다. 정상상태에서의 속도 및 유량을 분석값과 비교한 결과, 매우 작은 오차내에서 일치함을 알 수 있었다. 따라서, 본 연구에서 도출된 이론식을 바탕으로 비정상상태에서의 유량 변동 측정을 수행하는데 큰 역할을 할 수 있을 것이다.

  • PDF

사이클론 분리기 시스템 내에서의 가스 주입 유속에 따른 세라믹 입자 거동 전산모사 (Numerical investigation of ceramic particle movement for injected gas flow rate in cyclone separator system)

  • 우효상;심광보;정용재
    • 한국결정성장학회지
    • /
    • 제13권3호
    • /
    • pp.145-151
    • /
    • 2003
  • 전산유체역학을 이용하여 전형적인 구조를 갖는 사이클론 분리기 시스템 내에서의 주입 가스 유동 및 입자 거 동해석을 통해 가스 주입 유속에 따른 입자 거동 양상을 3차원적으로 해석하였다. 해석 결과는 Navier-stokes 방정식을 이용한 유체 유동 현상과 Lagrangian 접근법을 이용한 입자 거동 경로 추적을 결합시켜 도출되었다. 주입 유속이 증가함에 따라 내부 압력 손실이 증가하였고 이런 내부 압력 변화는 분리기 내의 유체의 유동 양상에 영향을 미쳤다. 입자의 거동은 유체의 유동에 의해 결정되었으며 일정 유속에 대해서는 입자의 크기에 크게 의존하였다. 그리고 주입 유속의 증가는 입자의 경로를 증가시키면서 분리기의 하부 영역으로 이동시켰다. 이로 인해 분리기내에 존재하는 입자의 최소 크기가 작아지며 일정 크기의 입자의 경우 분리율이 증가하였다. 결론적으로 가스 유입 유속의 변화는 내부의 유체 유동 변화와 입자 거동 양상에 중요한 요인이 된다.

Effects of Reynolds Number and Shape of Manifold on Flow Rate in Separator for Polymer Electrolyte Fuel Cell (ICCAS 2004)

  • Huang, Chaii;Ozawa, Yoshikuni;Ennoji, Hisayuki;Iijima, Toshio
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.68-71
    • /
    • 2004
  • Recently, a great deal of research and development of a fuel cell have been carried out to solve problems on the drain of fossil fuel, air pollution and global warning. In order to improve the efficiency of a fuel cell, it is necessary to clarify the flow in separator. In this study, distributions of velocity flow rate and pressure, and streamlines are examined in detail from numerical analysis with CFD code. In the experiment the distribution of flow rate is measured and flow in the each grooves of the separator is visualized by dye method changing Reynolds number. Furthermore, effects of size of the inlet and outlet manifolds and shape of ribs near the inlet outlet on the distributions of flow and pressure are examined.

  • PDF

난방시 실별 연동형 세대자동유량제어 시스템 (Auto Flow Rate Regulating System Synchronized with Room Control)

  • 김영균;김남근;서범석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.77-82
    • /
    • 2009
  • If we can supply accurate minute flow rate to the households, we can solve many problems that are occurring in consequences of uncontrolled flow rate for the households. Therefore, this paper presents an innovative solution to the source of the problems by illustrating how we can control the flow rate to the household. This paper proves such problems even can be solved in a case when there is a room turned off the heating.

  • PDF