• Title/Summary/Keyword: Flow uniform factor

Search Result 95, Processing Time 0.023 seconds

LAMINAR FLOW IN THE ENTRANCE REGION OF HELICAL TUBES FOR UNIFORM INLET VELOCITY CONDITIONS (균일입구유속 조건의 나선관 입구영역의 층류 유동)

  • Kim, Y.I.;Park, J.H.
    • Journal of computational fluids engineering
    • /
    • v.13 no.1
    • /
    • pp.21-27
    • /
    • 2008
  • A numerical study for laminar flow in the entrance region of helical tubes for uniform inlet velocity conditions is carried out by means of the finite volume method to investigate the effects of Reynolds number, pitch and curvature ratio on the flow development. This results cover a curvature ratio range of 1/10$\sim$1/320, a pitch range of 0.0$\sim$3.2, and a Reynolds number range of 125$\sim$2000. It has been found that the curvature ratio does significantly effect on the angle of flow development, but the pitch and Reynolds number do not. The characteristic angle $\phi_c(=\phi/\sqrt{\delta})$, or the non-dimensional length $\overline{l}(=l\sqrt{\delta}cos(atan\lambda)/d)$ can be used to represent the flow development for uniform inlet velocity conditions. In uniform inlet velocity conditions, the growth of boundary layer delays the flow development attributed to centrifugal force, and in which conditions the amplitude of flow oscillations is smaller than that in parabolic inlet velocity conditions. If the pitch increases or if the curvature ratio or Reynolds number decreases, the minimum friction factor and the fully developed average friction factor normalized with the friction factor of a straight tube and the flow oscillations decrease.

A study on a uniformity of flow field in a duct cooler of FGD system (배연탈황설비 덕트쿨러에서의 유동균일화에 관한 연구)

  • 배진효;김광추;박만흥;박경석;이종원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.2
    • /
    • pp.120-130
    • /
    • 2000
  • A flow uniformity in a duct cooler of duct system of FGD(Flue Gas Desulfurization) linking a reheater and a absorber has been investigated in the present study. For this purpose, the flow characteristics according to the geometry of a vertical and horizontal vane in a curved duct of the duct system has been examined with the aid of a numerical simulation. The results indicate that the vertical vane with a little deflection toward a recirculation region makes the flow distribution in the duct cooler more uniform than that without deflection, and horizontal vane does not effect the change of the flow distribution for an angle of inclination. The mean flow uniform factor shows its maximum for duct system without the vane(case NP) and its minimum for the vertical vane with a little deflection(case P-0.8-0) .

  • PDF

Design of Inlet Manifold for PEM Fuel Cells and Numerical Analysis (고분자 전해질 연료전지를 위한 연료주입구 설계 및 수치해석)

  • Uhm, Seung-Bae;Na, Tae-Kyung;Kim, Hong-Suk;Baek, Jung-Sik;Sung, Dong-Mug;Kim, Tae-Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.172-175
    • /
    • 2007
  • The Performance of a PEMFC stack is strongly dependent on the uniform reactants distribution on MEA. The uniform distribution can be achieved by flow-field pattern and manifold design optimized to satisfy operating conditions. This paper investigates uniform reactants distribution in channels by changing manifold shape and inlet mass flow rate. Typical U and Z shape and modified U and Z shape manifolds with buffer zone were designed. To check the uniform reactants distribution, standard deviation of mass flow rate was compared. The numerical results show that the inlet mass flow rate, inlet shape, and manifolds shape are critical factor for uniform distribution.

  • PDF

Friction Factor for Circular Pipe with Uniform Roughness (균일조도 원형관 마찰계수)

  • Yoo, Dong Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.5
    • /
    • pp.165-172
    • /
    • 1993
  • On the basis of Nikuradse laboratory experiments conducted in circular pipe with uniform roughness, five flow regimes are defined with respect to the characteristics of boundary layer such as laminar, transition laminar, smooth turbulent, transition turbulent and rough turbulent flows. Two cases are found for the transition laminar flow: one for the transition between laminar flow and smooth turbulent flow and the other for the one between laminar flow and rough turbulent flow. They all can be clearly determined by the relative roughness or the ratio of pipe diameter to the roughness. Explicit functions are developed for the estimation of pipe friction factor for the various flow conditions including turbulent flow regimes, which have excellent agreement with the Nikuradse laboratory data.

  • PDF

Microstructure and Mechanical Properties of Hot-Stamped 3.2t Boron Steels according to Water Flow Rate in Direct Water Quenching Process (3.2t 보론강 판재 직수냉각 핫스탬핑시 냉각수 유량에 따른 미세조직 및 기계적 특성)

  • Park, Hyeon Tae;Kwon, Eui Pyo;Im, Ik Tae
    • Korean Journal of Materials Research
    • /
    • v.30 no.12
    • /
    • pp.693-700
    • /
    • 2020
  • Direct water quenching technique can be used in hot stamping process to obtain higher cooling rate compared to that of the normal die cooling method. In the direct water quenching process, setting proper water flow rate in consideration of material thickness and the size of the area directly cooled in the component is important to ensure uniform microstructure and mechanical properties. In this study, to derive proper water flow rate conditions that can achieve uniform microstructure and mechanical properties, microstructure and hardness distribution in various water flow rate conditions are measured for 3.2 mm thick boron steel sheet. Hardness distribution is uniform under the flow condition of 1.5 L/min or higher. However, due to the lower cooling rate in that area, the lower flow conditions result in a drastic decrease in hardness in some areas in the hot-stamped part, resulting in low martensite fraction. From these results, it is found that the selection of proper water flow rate is an important factor in hot stamping with direct water quenching process to ensure uniform mechanical properties.

Determination of Thermal Dtress Intensity Factors for the Interface Crack under Vertical Uniform Heat Flow (수직 균일 열유동하에 있는 접합 경계면 균열의 열응력세기계수 결정)

  • 이강용;설창원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.201-208
    • /
    • 1991
  • In case that an interface crack exists in an infinite two-dimensional elastic bimaterial, the crack surface is insulated under traction free and the uniform heat flow vertical to the crack from infinite boundary is given. Temperature and stress potentials are obtained by using complex variable approach to solve Hilbert problems. The results are used to obtain thermal stress intensity factors. Only mode I thermal stress intensity factor occurs in case of the homogeneous material. Otherwise, mode I and II thermal stress intensity factor is much smaller than one of mode II.

Thermal Stress Intensity Factors for Partially Insulated Interface Crack under Uniform Heat Flow (부분 열유동이 있는 접합 경계면균열의 열응력세기계수 결정)

  • 이강용;박상준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.7
    • /
    • pp.1705-1712
    • /
    • 1994
  • Hilbert problems are derived to evaluate thermal stress intensity factors for a partially insulated crack subjected to vertically uniform heat flow in infinite bonded dissimilar materials. In case of fully insulated crack surface, the present solutions of thermal stress intensity factors are reduced into the same as the previous results. For the homogeneous material, mode II thermal stress intensity factor only exists. However, in the bonded dissimilar materials, both mode I and II thermal stress intensity factors are obtained. Specially, in this case, mode II thermal stress intensity factor is dominent. Also, thermal stress intensity factors are strongly influenced by the material properties. Thermal stress intensity factors decrease when the degree of insulation decreases.

Numerical Analysis for the Flow Uniformity in the LP-SCR Reactor (LP SCR 반응기 내 유동 균일도 개선을 위한 해석적 연구)

  • Um, Hyung Sik;Kim, Gun Ho;Kim, Dae Hee;Kim, Kyu Jong;Kim, Jung Rae
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.61-63
    • /
    • 2015
  • In the low pressure selective catalytic reduction (LP SCR) system, the uniformity of both ammonia concentration and exhaust gas flow at the SCR catalyst layer are important design factor for the efficient SCR-deNOx performance. According to the shape of the guide vane and static mixer, numerical simulations were conducted to analyze flow patterns and finally to find out the appropriate alternative for uniform flow at the front of catalyst in the real scale LP SCR reactor. The variations of gas velocity and ammonia concentration were quantitatively evaluated. Based on the present results, the shape was devised to satisfy the design criteria.

  • PDF

An Experimental Study of Turbulent Uniform Shear Flow in a Nearly Two-Dimensional $90^{\circ}$ Curved Duct (I) - Mean Flow Field- (2차원 $90^{\circ}$ 곡관에서 균일전단류의 특성에 대한 실험적 연구 (1) -평균유동장-)

  • 임효재;성형진;정명균
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.3
    • /
    • pp.834-845
    • /
    • 1995
  • An experimental study is made in a nearly two-dimensional 90.deg. curved duct to investigate the effects of interaction between streamline curvature and mean strain on turbulence. The initial shear at the entrance to the curved duct is varied by an upstream shear generator to produce five different shear conditions ; a uniform flow (UF), a positive weak shear (PW), a positive strong shear(PS), a negative weak shear (NW) and a negative strong shear(NS). With the mean field data of the case UF, variations of the momentum thickness, the shape factor and the skin friction over the convex(inner) surface and the concave (outer) surface are scrutinized quantitatively in-depth. It is found that, while the pressure loss due to curvature is insensitive to the inlet shear rates, the distributions of wall static pressure along both convex and concave surfaces are much influenced by the inlet shear rates.

An Experimental Study on Heat Transfer Characteristics with Turbulent Swirling Flow Using Uniform Heat Flux in a Cylindrical Annuli

  • Chang, Tae-Hyun;Lee, Kwon-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.2042-2052
    • /
    • 2003
  • An experimental study was performed to investigate heat transfer characteristics of turbulent swirling flow in an axisymmetric annuli. The static pressure, the local flow temperature, and the wall temperature with decaying swirl were measured by using tangential inlet conditions and the friction factor and the local Nusselt number were calculated for Re=30000∼70000. The local Nusselt number was compared with that obtained from the Dittus-Boelter equation with swirl and without swirl. The results showed that the swirl enhances the heat transfer at the inlet and the outlet of the test tube.