Numerical Analysis of Y-shaped Check Valve for Power Plant (발전소용 Y형 체크밸브에 관한 수치해석 연구)

  • Lee, Jae-Hun;Kim, Si-Pom;Jeon, Rock-Won;Lee, Geun-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.1
    • /
    • pp.129-135
    • /
    • 2016
  • Various type of valves are manufactured for different industrial uses. Among them, check valves are used to allow fluid to flow in one direction but not in the opposite direction. There are many different types of check valves, but Y-shaped check valves are widely used these days. Not many studies have been carried out on Y-shaped check valves and the flow coefficients obtained through numerical analysis have the problem of low reliability. In order to solve this problem, this study performed flow analysis, flow-structure coupled analysis, and flow coefficient measurement experimentally, and through these analyses derived and verified the flow coefficients and assessed the structural safety based on numerical analysis.

A Study on the Flow Field Analysis with a High-frequency Ultrasonic by PIV Measurement (PIV 계측에 의한 고주파수 초음파 유동장 해석에 관한 연구)

  • Lee, Sang-Bum;Song, Min-Geun;Son, Seung-Woo;Jeong, Gwang-Su;Ju, Eun-Sun
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.727-732
    • /
    • 2001
  • The purpose of this study is to compare the time mean velocity distribution, the time mean kinetic energy, and the time mean turbulence intensity between vertical and horizontal flow fields in a coaxial circular pipe by PIV measurement. Experiments are performed at a Reynolds number 2,000, measuring regions divided as the section regions A, B, C, D in flow fields. The angle of the high-frequency ultrasonic is selected in the direction of $45^{\circ}$ to the flow axes and it is reflected several times. In results, it is clarified that the effect of gravity is given in the vertical flow field compared with the horizontal flow field and the ultrasonic affects the turbulence enhancement. And kinetic energy and turbulence intensity with ultrasonic are shown slightly bigger than those in flow field without it.

  • PDF

Capillary Flow in Different Cells of Thuja orientalis, Gmelina arborea, Phellodendron amurense

  • Chun, Su Kyoung
    • Journal of the Korea Furniture Society
    • /
    • v.28 no.3
    • /
    • pp.248-258
    • /
    • 2017
  • A study was carried out to observe the 1% aqueous safranine solution flow speed in longitudinal and radial directions of softwood Thuja orientalis L., diffuse-porous wood Gmelina arborea Roxb., and ring-porous wood Phellodendron amurense Rupr., Longitudinal flow was considered from bottom to top while the radial flow was considered from bark to pith directions. In radial direction, ray cells and in longitudinal direction tracheids, vessel and wood fiber were considered for the measurement of liquid penetration speed at less than 12% moisture contents(MC). The variation of penetration speed for different species was observed and the reasons behind for this variation were explored. The highest radial penetration depth was found in ray parenchyma of T. orientalis but the lowest one was found in ray parenchyma of P. amurense. The average liquid penetration depth in longitudinal trachied of T. orientalis was found the highest among all the other cells. The penetration depth in fiber of G. arborea was found the lowest among the other longitudinal cells. It was found that cell dimension and also meniscus angle of safranine solution with cell walls were the prime factors for the variation of liquid flow speed in wood. Vessel was found to facilitate prime role in longitudinal penetration for hardwood species. The penetration depth in vessel of G. arborea was found highest among all vessels. Anatomical features like ray parenchyma cell length and diameter, end-wall pits number were found also responsible fluid flow differences. Initially liquid penetration speed was high and the nit gradually decreased in an uneven rate. Liquid flow was captured via video and the penetration depths in those cells were measured. It was found that even in presence of abundant rays in hardwood species, penetration depth of liquid in radial direction of softwood species was found high. Herein the ray length, lumen area, end wall pit diameter determined the radial permeability. On the other hand, vessel and fiber structure affected the longitudinal flow of liquids. Following a go-stop-go cycle, the penetration speed of a liquid decreased over time.

Measurement of Developing Turbulent Flows in a 90-Degree Square Bend with Spanwise Rotation

  • Choi Young Don;Kim Dong Chul;Lee Kun Hee
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.7
    • /
    • pp.1503-1516
    • /
    • 2005
  • Mean flow and turbulence properties of developing turbulent flows in a 90 degree square bend with span-wise rotation are measured by a hot-wire anemometer. A slanted wire is rotated into 6 orientations and the voltage outputs from them are combined to obtain the mean velocity and the Reynolds stress components. Combined effects of the centrifugal and Coriolis forces due to the curvature and the rotation of the bend on the mean motion and turbulence structures are investigated experimentally. Results show that the two body forces can either enhance or counteract each other depending on the flow direction in the bend.

Measurement of Residual Stress Distribution in Injection-Molded Short Fiber Composites (단섬유 복합재료 사출성형물의 잔류응력 측정)

  • 김상균;이석원;윤재륜
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.10a
    • /
    • pp.61-63
    • /
    • 2001
  • Residual stress distribution in injection-molded short fiber composites was determined using layer-removal method. Polysterene with 3 vol% carbon fibers was injection-molded into the tensile specimen. With milling machine layer-removal process was conducted and the curvature data were acquired. Treuting and Read analysis which is assuming isotropic material, and White analysis considering anisotropy due to the fiber orientation were used to calculate residual stress of the flow direction through the thickness direction and compared with each other.

  • PDF

A Study on Wave Observation System with GPS Arrayed Buoys by using MUSIC Method

  • Yoo, Yun-Ja;Song, Chae-Uk;Kouguchi, Nobuyoshi;Fujii, Hidenobu
    • Journal of Navigation and Port Research
    • /
    • v.27 no.6
    • /
    • pp.677-682
    • /
    • 2003
  • The long-period gravity wave, the wave period from some ten seconds to some minutes, induces not only the big sway of a ship moored and berthed in the harbor due to the horizontal long-distance motion of a water but also strong exfoliated flow and vortices near the harbor entrance. They muse serious problems on the safety navigation of vessels entering and leaving the harbor, but this gravity wave has not been searched sufficiently yet. Then it is quite important to reveal the characteristics of this long-period gravity wave ana to solve various problems induced by this wave. The long-period gravity wave measurement system with arrayed buoys installed the kinematic GPS was already proposed, which provides the precise propagating direction of the long-period gravity wave. In this paper, the observation results of the wave measurement system are shown by the MUSIC method And the propagating wave direction was estimated precisely enough in comparison with other results used other method.

Air Flow Rate Measurement in Multi Point Injection Engine U sing Ultrasonic Sensors (초음파센서를 이용한 전자식 연료분사엔진의 흡기유량측정)

  • Park, K.S.;Kim, J.I.;Kauh, S.K.;Noh, S.T.;Lee, J.H.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.3
    • /
    • pp.58-65
    • /
    • 1995
  • In this study an air flow meter was developed for MPI engine using ultrasonic sensors. The major characteristcs of the ultrasonic flow meter are high speed response, flow direction recognition and linear output. The air flow rate measurements were conducted at upstream of the throttle and intake manifold. The characteristics of the ultrasonic flow meter are compared with those of the Bosch hot wire flow meter at both steady and unsteady engine conditions.

  • PDF

Capillary Flow in Different Cells of Metasequoia glyptostroboides, Anthocephalus cadamba, and Fraxinus rhynchophylla (메타세콰이어, 카담, 물푸레나무 세포내강의 액체이동)

  • Chun, Su Kyoung
    • Journal of the Korea Furniture Society
    • /
    • v.29 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • A study was carried out to observe the 1% aqueous safranine solution flow speed in longitudinal and radial directions of softwood Metasequoia glyptostroboides, diffuse-porous wood Anthocephalus cadamba and ring-porouswood Fraxinus rhynchophylla. In radial direction, ray cells and in longitudinal direction, tracheids, vessel and wood fiber were considered for the measurement of liquid penetration speed at less than 12% moisture contents (MC). The length, lumen diameter, pit diameter, end wall pit diameter and the numbers of end wall pits determined for the flow rate. The liquid flow in the those cells was captured via video and the capillary flow rate in the ones were measured. Vessel in hardwood species and tracheids in softwood was found to facilitate prime role in longitudinal penetration. Anatomical features like the length and diameter, end-wall pit numbers of ray parenchyma were found also responsible fluid flow differences. On the other hand, vessel and fiber structure affected the longitudinal flow of liquids. Therefore, the average liquid penetration depth in longitudinal tracheids of Metasequoia glyptostroboides was found the highest among all cells considered in Anthocephalus cadamba and Fraxinus rhynchophylla In radial direction, ray parenchyma of Metasequoia glyptostroboides was found the highest depth and the one of Fraxinus rhynchophylla was the lowest. The solution was penetrated lowest depth in the wood fiber of Fraxinus rhynchophylla. The large vessel of Fraxinus rhynchophylla was found the lowest depth among the vessels. The solutin was penetrated to the wood fiber of Anthocephalus cadamba higher than the one of Fraxinus rhynchophylla.

  • PDF

Capillary Flow in Different Cells of Larix Kaempferi, Betula Davurica, Castanea crenata (일본잎갈나무, 물박달나무, 밤나무 세포내강의 액체이동)

  • Chun, Su Kyoung
    • Journal of the Korea Furniture Society
    • /
    • v.28 no.1
    • /
    • pp.88-93
    • /
    • 2017
  • A study was carried out to observe the 1% aqueous safranine solution flow speed in longitudinal and radial directions of softwood Larix kaempferi (Lamb.)Carriere, diffuse-porous wood Betula davurica Pall.. and ring-porouswood Castanea crenata S.etZ. In radial direction, ray cells and in longitudinal direction, tracheids, vessel and wood fiber were considered for the measurement of liquid penetration speed at less than 12% moisture contents (MC). The length, lumen diameter, pit diameter, end wall pit diameter and the numbers of end wall pits determined for the flow rate. The liquid flow in the those cells was captured via video and the capillary flow rate in the ones were measured. Vessel in hardwood species and tracheids in softwood was found to facilitate prime role in longitudinal penetration. Anatomical features like the length and diameter, end-wall pit numbers of ray parenchyma were found also responsible fluid flow differences. On the other hand, vessel and fiber structure affected the longitudinal flow of liquids. Therefore, the average liquid penetration depth in longitudinal tracheids of Larix kaempferi was found the highest among all cells considered in Betula davurica and Castanea crenata, In radial direction, ray parenchyma of Larix kaempferi was found the highest depth and the one of Betula davurica was the lowest. The solution was penetrated lowest depth in the wood fiber of Castanea crenata. The large vessel of Castanea crenata was found the lowest depth among the vessels. The solutin was penetrated to the wood fiber of Betula davurica higher than the one of Castanea crenata.

Measurement of Flow Velocity and Flow Visualization with MR PC Image (MR PC 영상을 이용한 유체 흐름 분석)

  • Kim, S.J.;Lee, D.H.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.127-130
    • /
    • 1997
  • Phase-contrast(PC) methods have been used for quantitative measurements of velocity and volume flow rate. In addition, phase contrast cine magnetic resonance imaging (MRI) combines the flow dependent contrast of PC MRI with the ability of cardiac cine imaging to produce images throughout the cardiac cycle. In this method, the through-plane velocity has been encoded generally. However, the accuracy of the flow data can be reduced by the effect of flow direction, finite slice thickness, resolution, pulsatile flow pattern, and so on. In this study we calculated the error caused by misalignment of tomographic plane and flow directon. To reduce this error and encode the velocity for more complex flow, we suggested 3 directional velocity encoding method.

  • PDF