• Title/Summary/Keyword: Flow condition

Search Result 5,289, Processing Time 0.031 seconds

An Implementation of the Robust Inviscid Wall Boundary Condition in High-Speed Flow Calculations

  • Kim, Moon-Sang;Jeon, Byung-Woo;Kim, Yong-Nyun;Kwon, Hyeok-Bin;Lee, Dong-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.671-680
    • /
    • 2001
  • Boundary condition is one of the major factors to influence the numerical stability and solution accuracy in numerical analysis. One of the most important physical boundary conditions in the flowfield analysis is the wall boundary condition imposed on the body surface. To solve a two-dimensional Euler equation, totally four numerical wall boundary conditions should be prescribed. Two of them are supplied by the flow tangency condition. The other two conditions, therefore, should be prepared additionally in a suitable way. In this paper, four different sets of wall boundary conditions are proposed and then applied to solve high-speed flowfields around a quarter circle geometry. A two-dimensional compressible Euler solver is prepared based on the finite volume method. This solver hires three different upwind schemes; Steger-Warmings flux vector splitting, Roes flux difference splitting, and Lious advection upstream splitting method. It is found that the way to specify the additional numerical wall boundary conditions strongly affects the overall stability and accuracy of the upwind schemes in high-speed flow calculation. The optimal wall boundary conditions should be also chosen very carefully depending on the numerical schemes used to solve the problem.

  • PDF

Solutions of the Navier-Stokes equation in slip flow region (Slip flow 영역에서 Navier Stokes 방정식의 해석 연구)

  • Park, W.H.;Kim, T.K.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.597-602
    • /
    • 2000
  • In a MEMS(micro-electro mechanical system), the fluid may slip near the surface of a solid and have a discontinuous temperature profile. A numerical prediction in this slip flow region can provide a reasonable guide for the design and fabrication of micro devices. The compressible Navier-Stokes equation with Maxwell/smoluchowski boundary condition is solved for two simple systems; couette flow and pressure driven flow in a long channel. We found that the couette flow could be regarded as an incompressible system in low speed regions. For the pressure driven flow system, we observed nonlinear distribution of pressure in the long channel and numerical results showed a good agreement with the experimental results.

  • PDF

Analysis of Performance Characteristics by Inner Flow Path of Side Channel Type Ring Blower (사이드 채널형 링블로워의 임펠러 내부 유로에 따른 성능변화 분석)

  • Lee, Kyoung-Yong;Choi, Young-Seok;Jeong, Kyung-Ho;Park, Woon-Jean
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.4
    • /
    • pp.67-71
    • /
    • 2012
  • This study analyzed performance changes by an inner flow path of impeller groove for side channel type ring blower using CFD. Two models have the same side channel and clearance while one has an inner flow path and the other doesn't. To analyze the performance change of a ring blower, overall performance and local flow field were analyzed. For the overall performance, pressure increase and impeller torque were checked under the design flow condition. Under the design flow condition, pressure increase was greater for the model with the inner flow path. The model with the inner flow path showed improved efficiency because the area subject to torque decreased due to the creation of inner flow path. To analyze local flow field, a section was created from the representative location of each impeller groove toward the direction of radius. Inner channel pressure distribution depending on the rotation direction shows that the model with the inner flow path has pressure equilibrium of working fluid through the inner flow path. Velocity distribution of inside impeller groove shows that flow field was coupled and appeared to form an inner wall where the flow field was stabilized.

A Study on the Deposition Condition for Stoichimetric $\textrm{Ta}_2\textrm{O}_5$ Thin Films by DC Magnetron Reactive Sputtering Technique (DC Magnetron 반응성 스퍼터링 방법을 이용한 stoichiometric $\textrm{Ta}_2\textrm{O}_5$막의 증착조건에 관한 연구)

  • Jo, Seong-Dong;Baek, Gyeong-Uk
    • Korean Journal of Materials Research
    • /
    • v.9 no.6
    • /
    • pp.551-555
    • /
    • 1999
  • The deposition condition to obtain stoichiometric $Ta_2$O\ulcorner films, which is still controversial, using magnetron reactive sputtering was studied. The films were deposited by varying $O_2$gas flow rate with sputtering power and Ar gas flow rate of 200W and 60 sccm fixed. At the conditions of $O_2$ gas flow rate over 20 sccm, amorphous Tantalum oxide films with the refractive index of 2.1 and dielectric constant of 25 were deposited. Among those films, the capacitors dielectric properties of the film deposited at the condition of $O_2$ gas flow rate 50 sccm was best, the leakage current was 1$\times$10\ulcornerA/$\textrm{cm}^2$ at the electric field strength of 0.5 MC/cm and the breakdown field strength was over 2.0 MV/cm. This result could be explained from the analysis comparing with a standard sample using RBS because the composition of the film deposited at this condition was closest to the stoichiometric $Ta_2$O\ulcorner. The result of XPS analysis convinced that this film was stoichiometric $Ta_2$O\ulcorner film. A maximum cathode voltage was observed when $O_2$gas flow rate was 30 sccm. This shows that the Schiller's proposition that one can obtain stoichiometric films at the condition of maximum cathode voltage is not correct and more oxygen than that of the maximum voltage condition is necessary to deposit the stoichiometric Ta$_2$O\ulcorner films.

  • PDF

Analysis of Flow through High Pressure Bypass Valve in Power Plant (발전소용 고압 바이패스 밸브의 유동해석)

  • Cho, An-Tae;Kim, Kwang-Yong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2558-2562
    • /
    • 2007
  • In the present work, flow characteristics analysis has been performed for steam turbine bypass control valve (single-path type). The numerical analysis is performed by solving three-dimensional Reynolds-averaged Navier-Stokes (RANS) equations. Shear stress transport (SST) model is used as turbulence closure. Symmetry condition is applied at the mid plane of the valve while adiabatic condition is used at the outer wall of the cage. Grid independency test is performed to find the optimal number of grid points. The pressure and temperature distributions on the outer wall of the cage are analyzed. Mass flow rate at maximum plug opening condition is compared with the designed mass flow rate.

  • PDF

Predictions of Microscale Separated Flow using Langmuir Slip Boundary Condition (Langmuir 미끄럼 경계조건을 이용한 미소 박리유동의 예측)

  • Lee, Do-Hyung;Meang, Joo-Sung;Choi, Hyung-Il;Na, Wook-Sang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1097-1104
    • /
    • 2003
  • The current study analyzes Langmuir slip boundary condition theoretically and it is tested in practical numerical analysis for separation-associated flow. Slip phenomenon at the channel wall is properly implemented by various numerical slip boundary conditions including Langmuir slip model. Compressible backward-facing step flow is compared to other analysis results with the purpose of diatomic gas Langmuir slip model validation. The numerical solutions of pressure and velocity distributions where separation occurs are in good agreement with other numerical results. Numerical analysis is conducted for Reynolds number from 10 to 60 for a prediction of separation at T-shaped micro manifold. Reattachment length of flows shows nonlinear distribution at the wall of side branch. The Langmuir slip model predicts fairly the physics in terms of slip effect and separation.

Gas Flow in a Rapidly Rotating Pipe with Azimuthal-Varying Thermal Wall Condition (회전방향 온도변화를 갖는 매우 빠르게 회전하는 파이프 내의 기체유동)

  • Park, Jun-Sang;Hyun, Jae-Min
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.628-633
    • /
    • 2003
  • An analysis on the steady-state has been made of flow of a compressible fluid rapidly-rotating in a pipe. The flow is induced by an small arbitrary azimuthally-varying thermal forcing added on the basic state of rigid body isothermal rotation. The system Ekman number is assumed to be very small value. Analytic solutions have been obtained for axisymmetric and non-axisymmetric types, in which the axisymmetric solution comes from the azimuthally-averaged wall boundary condition and the non-axisymmetric solution from fluctuating wall boundary condition.

  • PDF

Characteristics of Noise Attenuation with the Variation of Flow Condition and Hole Shape of Perforated Intruding Tues in Muffler (유동조건과 내부관 구명형상의 변화에 따른 소음기의 소음저감 특성)

  • Jung, Jin-Nyon;Kim, Won-Jin;Cho, Bum-Rae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.10
    • /
    • pp.87-93
    • /
    • 1999
  • To propose a useful modelling method for an actual muffler, the noise attenuation effects of muffler was investigated according to the flow condition and the hole shape of tubes. In this work, the finite element method was used to calculate the transmission loss of muffler, The noise attenuation characteristics of four different types of muffler in the hole shape of tubes were compared mutually to find a more simple equivalent model. Analytical results showed that the overall value of transmission loss increases and the peaks of transmission loss curve shift to the low frequency with mean flow for the given muffler, Also the noise attenuation characteristics of the equivalent model having the split holes is almost the same as those of the actual muffler having many circular holes.

  • PDF

Corrosion Behavior of Nickel-Plated Alloy 600 in High Temperature Water

  • Kim, Ji Hyun;Hwang, Il Soon
    • Corrosion Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.61-67
    • /
    • 2008
  • In this paper, electrochemical and microstructural characteristics of nickel-plated Alloy 600 were investigated in order to identify the performance of electroless Ni-plating on Alloy 600 in high-temperature aqueous condition with the comparison of electrolytic nickel-plating. For high temperature corrosion test of nickel-plated Alloy 600, specimens were exposed for 770 hours to typical PWR primary water condition. During the test, open circuit potentials (OCP's) of all specimens were measured using a reference electrode. Also, resistance to flow accelerated corrosion (FAC) test was examined in order to check the durability of plated layers in high-velocity flow environment at high temperature. After exposures to high flow rate aqueous condition, the integrity of surfaces was confirmed by using both scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). For the field application, a remote process for electroless nickel-plating was demonstrated using a plate specimen with narrow gap on a laboratory scale. Finally, a practical seal design was suggested for more convenient application.

Performance Characteristics of Cooling Tower on Small Absorption Chiller (가정용 흡수식 냉온수기용 냉각탑의 성능특성)

  • Sarker M.M.A;Kim Eun-Pi;Jeong Seok-Kwon;Min Kyung-Hyun;Kim Jae-Dol;Yoon Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.7
    • /
    • pp.1145-1151
    • /
    • 2004
  • The experiment of thermal performance about cross flow type cooling tower was conducted in this study. Generally the ambient air condition can affect the thermal performance of cooling tower to improve or not. However it is hard to control the cooling water temperature that we want under bad air condition or during rainy season. In this paper, the effect of variables, which the ambient air have. especially wet-bulb temperature, are experimentally investigated for controlling the cooling water temperature more successfully. The result is that there is appropriate air flow rate in respective air condition to preserve the cooling performance in the cooling tower and the maximum air flow rate can't overcome the approach under bad air condition.