• 제목/요약/키워드: Flow balancing

검색결과 152건 처리시간 0.024초

유연 PCB 자동삽입라인의 부하 평준화를 위한 작업흐름선택모델 (Job Route Selection Model for Line Balancing of Flexible PCB Auto-Insertion Line)

  • 함호상;김영휘;정연구
    • 대한산업공학회지
    • /
    • 제20권4호
    • /
    • pp.5-21
    • /
    • 1994
  • We have described the optimal process route selection model for the PCB(printed circuit board) auto-insertion line. This PCB assembly line is known as a FFL(flexible flow line) which produces a range of products keeping the flow shop properties. Under FFL environments, we have emphasized the balancing of work-loads in order to maximize total productivity of PCB auto-insertion line. So we have developed a heuristic algorithm based on a work-order selection rule and min-max concept for the job route selection model.

  • PDF

턱관절 균형과 경맥유주의 상응관계 연구 (The Relationship between the Temporomandibular Joint (TMJ) and Meridian Flow)

  • 손인철
    • 턱관절균형의학회지
    • /
    • 제1권1호
    • /
    • pp.1-8
    • /
    • 2011
  • Objectives: TMJ is the joint that connects the mandible to the skull, and it balances the body by holding the skull in the right position. The Meridian flows through the whole body. The objective of this study is to examine and clarify the relationship between the Temporomandibular Joint (TMJ) and the Meridian flow, especially around the TMJ. Methods: We reviewed the literature on the 8 Extra Meridians and the 12 Main Meridians around the TMJ. Results & Conclusion: Eight Extra Meridians keep the balance and harmony of the TMJ, and also play an important role in maintaining equilibrium of Yin and Yang of the whole body. The 12 Main Meridians, twelve Meridian Divergence (12經別) and Meridian Sinew also play an important role in the balance and harmony of the whole body based on the function of the Vicera and Bowels (臟腑). So it is conceivable that the role of TMJ is important in terms of health care.

  • PDF

4-레벨 인버터의 DC-링크 전압 균형을 위한 향상된 전압 제어 기법 (An Improved Voltage Control Scheme for DC-Link Voltage Balancing in a Four-Level Inverter)

  • 김래영;이요한;최창호;현동석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권10호
    • /
    • pp.544-554
    • /
    • 1999
  • Multi-level inverters are now receiving widespread interest form the industrial drives for high power variable speed applications. Especially, for the high power variable speed applications, a diode clamped multi-level inverter has been widely used. However, it has the inherent problem that the voltage of the link capacitors fluctuates. This paper describes a voltage control scheme effectively to suppress the DC-link potential fluctuation for a diode clamped four-level inverter. The current to flow from/into the each link capacitor is analyzed and the operation limit is obtained when a conventional SVPWM is used. To overcome the operation limit, a modified carrier-based SVPWM is proposed. Various simulation and experiment results are presented to verify the proposed voltage control scheme for DC-link voltage balancing.

  • PDF

Congestion-Aware Handover in LTE Systems for Load Balancing in Transport Network

  • Marwat, Safdar Nawaz Khan;Meyer, Sven;Weerawardane, Thushara;Goerg, Carmelita
    • ETRI Journal
    • /
    • 제36권5호
    • /
    • pp.761-771
    • /
    • 2014
  • Long-Term Evolution employs a hard handover procedure. To reduce the interruption of data flow, downlink data is forwarded from the serving eNodeB (eNB) to the target eNB during handover. In cellular networks, unbalanced loads may lead to congestion in both the radio network and the backhaul network, resulting in bad end-to-end performance as well as causing unfairness among the users sharing the bottleneck link. This work focuses on congestion in the transport network. Handovers toward less loaded cells can help redistribute the load of the bottleneck link; such a mechanism is known as load balancing. The results show that the introduction of such a handover mechanism into the simulation environment positively influences the system performance. This is because terminals spend more time in the cell; hence, a better reception is offered. The utilization of load balancing can be used to further improve the performance of cellular systems that are experiencing congestion on a bottleneck link due to an uneven load.

Multi-objective Unbalanced Distribution Network Reconfiguration through Hybrid Heuristic Algorithm

  • Mahendran, G.;Sathiskumar, M.;Thiruvenkadam, S.;Lakshminarasimman, L.
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.215-222
    • /
    • 2013
  • Electrical power distribution systems are critical links between the utility and customer. In general, power distribution systems have unbalanced feeders due to the unbalanced loading. The devices that dependent on balanced three phase supply are affected by the unbalanced feeders. This necessitates the balancing of feeders. The main objective of reconfiguration is to balance the loads among the phases subject to constraints such as load flow equations, capacity and voltage constraints and to reduce the real power loss, while subject to a radial network structure in which all loads must be energized. Therefore, the distribution system reconfiguration problem has been viewed as multi-objective problem. In this paper, the hybrid heuristic algorithm has been used for reconfiguration, which is the combination of fuzzy and greedy algorithms. The purpose of the introduction of greedy is to refrain the searching for the period of phase balancing. The incorporation of fuzzy helps to take up more objectives amid phase balancing in the searching. The effectiveness of the proposed method is demonstrated through modified IEEE 33 bus and modified IEEE 125 bus radial distribution system.

공동주택 온수난방 시스템의 적정 열공급을 위한 배관망 시뮬레이션 (Simulation of Pipe Network for Optimum Heat Supply in the Hot Water Heating System of Apartment House)

  • 김주용;민만기;최영돈
    • 설비공학논문집
    • /
    • 제5권3호
    • /
    • pp.157-168
    • /
    • 1993
  • Pipe network of hot water heat supply system in an apartment house was analyzed. Flowrate and supply heat capacity of each household in which constant flowrate balancing valve is installed in a single zone system were calculated and the results were investigated. In the existing piping system, the non-uniformity of heat supply with floors due to the static pressure and temperature difference between supply main and return main can not be avoided and this tendency get intense with the increase of the height of building. The non-uniformity of heat supply can be prevented by the installation of balancing valve at each household, however if the performance of supply pump is not sufficient to overcome the energy loss due to the installation of balancing valve for constant flow rate or if the selection of the valve capacity is not adequate, the valves will may lose their controllability.

  • PDF

오픈플로우 기반의 과학실험데이터센터 네트워크의 성능 향상을 위한 스케줄링 알고리즘 (A Scheduling Algorithm for Performance Enhancement of Science Data Center Network based on OpenFlow)

  • 공정욱;민석홍;이재용;김병철
    • 한국정보통신학회논문지
    • /
    • 제21권9호
    • /
    • pp.1655-1665
    • /
    • 2017
  • 최근 많은 클라우드 서비스 제공자, 기업, 연구소 등에서 데이터센터를 활발히 구축하고 있다. 일반적으로 데이터 센터는 부하 분산을 위해 ECMP 데이터 포워딩 기법을 사용하여 트리 토폴로지 형태로 구축된다. 본 논문에서는 트리 토폴로지와 팻트리 토폴로지를 살펴보고, 또한 MLAG와 ECMP 같은 부하 분산 기술을 알아본다. 그리고 데이터 센터내의 호스트에 저장되어 있는 특정 파일을 데이터센터 외부로 효율적으로 송신할 수 있는 스케줄링 알고리즘을 제안한다. 제안된 알고리즘은 팻트리 토폴로지와 오픈플로우 프로토콜을 이용한다. 수치해석을 통해 성능 분석을 수행하며, ECMP의 성능과 비교한다. 이러한 성능 비교를 통해 평균처리율과 파일전송완료시간에 있어서 제안된 알고리즘의 성능이 우수함을 보인다.

도시부 주행 차로수 일치에 따른 효과 분석 - 국도32호선 대전광역시 통과구간 대상 - (Effectiveness Analysis of Lane Balancing in Urban Areas)

  • 장일준
    • 대한토목학회논문집
    • /
    • 제31권2D호
    • /
    • pp.203-208
    • /
    • 2011
  • 우리나라 대부분의 도시는 지속적인 개발에 따라 교통 수요가 급속도로 증가하고 있다. 이에 따라 도로용량 증대를 위한 도로 확장 등이 이루어지고 있으나 동일 교통 특성을 지니는 구간 내에서 일부 구간만의 확장으로 전체적인 주행 차로 수 균형이 유지되고 있지 않아 차량 소통 및 교통안전 측면에서 문제가 발생하고 있다. 본 연구에서는 국도 32호선 대전광역시 통과 구간 중 직진 주행 차로 수가 일치하지 않는 구간을 중심으로 차로 수 불일치에 따른 문제점을 분석하고 차로 수를 일치하였을 경우의 효과에 대한 분석을 실시하였다. 분석 방법으로는 마이크로 시뮬레이션인 VISSIM을 활용하였으며 개선 전후의 평균 통행속도, 지체도, 상충 수 등을 비교 분석하였다. 분석결과 주행 차로 수 일치에 따라 지체도가 감소하고 평균 통행속도가 증가하였다. 본 연구결과는 주행 차로 수 일치의 중요성을 부각시켜 향후 도로확장 등 개선 공사 시행에서 병목현상 개선 및 차량 상충 감소에 기여할 것으로 판단된다.

정풍량방식 덕트에서 이중압력측정방법을 이용한 취출구 풍량조정 (Balancing air flow at terminal in CAV duct system with DPM method)

  • 이대우;박명식;박영우
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.66-78
    • /
    • 1998
  • Adequate ventilation with the proper amount of air to the right place is important factor to achieve a good Indoor air climate. Thus it is of prime importance that the ventilation system is working properly. This requires reliable pressure loss calculation to balance the air flow through duct systems. So a computer program for balancing CAV duct system is developed In this study. The results of CAV duct system is compared with the "Balans" code developed by Larsen from Norway. To obtain the pressure drop characteristics of damper at duct terminal, some experiments are performed using DPM(Dual Pressure Measurement) system. To adjust the resistance of damper, present study suggests that some special diffusers should be designed and damper producers should give the data of air flow vs. pressure drop to the customs when they manufacture the damper. One of the results concludes that the working time can be reduced from several minutes to several seconds per damper in the present experimental site, if the DPM system and the air volume adjusting process are used.

  • PDF

온돌난방제어 시 시스템저항 변화에 따른 유량 밸런싱에 관한 연구 (A Study for Flow-rate Balancing when the System Resistance Changes in the Control of the Radiant Floor Heating System)

  • 최정민;이규남;류성룡;김광우;여명석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.129-134
    • /
    • 2005
  • The behavior of whole system is affected by a minor change of system in the hydronic radiant floor heating system. Under partial load condition, the change of system resistance causes overflow of supply water. This unexpected effect is the cause of several problems in the heating system. In this study, we find some factors were validated with several computer simulations. After validation of this result, several conceptual solutions are evaluated to prevent overflow.

  • PDF