• Title/Summary/Keyword: Flow Value

Search Result 3,536, Processing Time 0.04 seconds

Flow Analyses using FLUENT 5.4 Code for the Bi-directional Flow Tube (FLUENT 5.4 코드를 이용한 양방향 유동 튜브에 대한 유동해석)

  • Kang, Kyoung-Ho;Yun, Byung-Jo;Baek, Won-Pil
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.934-938
    • /
    • 2003
  • Flow analyses using FLUENT 5.4 code were performed to validate the application of the local bidirectional flow tube in case of water and air flow. In this study, sensitivity studies have been performed to optimize the design features of the bi-directional flow tube which can be applied for the various experimental conditions. 2-dimensional axisymmetric steady state flow analyses have been performed. By calculating the differential pressure at both the front and the rear hole of the flow tube, K values were evaluated. The K values show good linearity regardless of the tube sizes and the Re numbers in both water and air flow. And system pressure and water subcooling didn’'t affect the K values. Under the elevated pressure of 80bar with 80K water subcooling, the K value indicates a similar trend with the case of 2bar with 80K water subcooling.

  • PDF

Flow Analysis of Parshall Flume Using FLOW-3D (FLOW-3D에 의한 파샬플륨 흐름 해석)

  • Oh, Byoung-Dong;Kim, Kyoung-Ho;Lee, Whan-Gi;An, Sang-Do
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.5
    • /
    • pp.375-386
    • /
    • 2004
  • A water shortage is one of the most important factors for development and management of water resources. For reliable water shortage measurement in a stream, Korea Water Resources Corporation(KOWACO) founded five foot Parshall flume at Yong-dam experimental watershed in 2000. The Parshall flume has a specially designed shape to facilitate flow measurements by eliminating sediment deposition problem that could lead to an incorrect measurement. In this study, computational fluid dynamics(CFD) model was used to analyze flow behavior of Parshall Flume under free discharge of five headwater level cases. The flow rates computed by CFD model are compared with those by ISO's formula, USBR's formula and stage-discharge rating curves. Flow rates computed by ISO's and USBR's formula are mostly same, but flow rate by CFD model is larger than empirical value by 9% and flow rate by stage-discharge rating curves is less than empirical value by 16%.

Effect of sewage flow on treatment efficiency of small scale wastewater treatment plant in rural community (농촌 지역에서 유입 유량이 소규모 하수처리장 처리 효율에 미치는 영향)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.18 no.3
    • /
    • pp.267-274
    • /
    • 2016
  • Sewerage supply in rural community is the important for water quality protection of water system such as river, lake and wetland. And characteristic of small scale wastewater system that have wide range of inflow and concentration in sewage should be considered for stable operation of small scale wastewater treatment plant. In this research, characteristics of flow ratio (flow / designed flow), effect on treatment efficiency of small scale wastewater treatment plant and assessment of optimal flow ratio were conducted through analysis on operation result of 18 small scale wastewater treatment plant in Bong-hwa gun. As a result, flow ratio shows the higher value during summer. However pollutants concentration in sewage was shown the higher concentration during autumn and winter. Treatment of small scale wastewater treatment plant is increased when flow ratio increased, and nutrient treatment efficiency is more sensitive to change of flow ratio than organic compound and suspended solids. According to this research result, it need to be maintained flow ratio 0.8 over value for stable treatment efficiency of small scale wastewater treatment plant.

Improvement of a Flow Coefficient for the Recirculation Chill-down Flow in a Main Oxidizer Shut-off Valve (연소기 산화제 개폐밸브 재순환예냉 유로의 유량계수 개선)

  • Hong, Moongeun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.4
    • /
    • pp.89-95
    • /
    • 2017
  • The improvement of a flow coefficient for the recirculation chill-down flow in a main oxidizer shut-off valve has been presented. The flow coefficient, which is mainly affected by the recirculation outlet port size and the configuration inside the valve, has been predicted with measured flow coefficient values. The comparison of experimentally measured flow coefficient with the predicted value shows the effect of valve inside configuration on the flow coefficient. Consequently, the flow coefficient is twice the previous value and about 75% of the pressure loss assigned to the main oxidizer shut-off valve can be used for additional pressure losses for other components in the recirculation chill-down system of a launch vehicle.

Steady Flow Characteristics of Flow-Intensifying Valve Configurations (유동 강화형 밸브의 형상에 따른 정상 유동 특성)

  • Choi, Su-Jin;Ryoo, Ki-Hyun;Jeon, Chung-Hwan;Chang, Young-June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.2
    • /
    • pp.166-174
    • /
    • 1999
  • The flow characteristics of 2-valve and 4-valve cylinder heads with various blocked-valve were experimentally investigated in a steady flow rig. Effects of the blocked-valve configurations on flow coefficient, swirl and tumble intensity are studied. Compared to the conventional valve, the blocked valve in both cylinder heads have the much lower flow coefficient and the much higher intensity of swirl and tumble. Under the same size of blockage, the value of flow coefficient and swirl(or tumble) intensity were varied according to the position of blockage. Throughout these steady flow test the optimized positions of blockage in both cylinder heads were determined.

STUDY ON TWO-DIMENSIONAL LAMINAR FLOW PAST A VERTICAL PLATE IN A MICROCHANNEL (마이크로채널 내의 수직 평판을 지나는 2차원 층류유동장에 대한 연구)

  • Yoon, Seok-Hyun;Jeong, Jae-Tack
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.233-238
    • /
    • 2010
  • A two-dimensional laminar flow past a vertical plate in a microchannel is investigated. At far upstream and downstream from the plate in the microchannel, the plane Poiseuille flow exists. The Stokes flow for this microchannel is investigated analytically and then the laminar flow by numerical method. For the Stokes flow analysis, the method of eigenfunction expansion is used. From the results, the streamline pattern and the pressure distribution are plotted, and the additional pressure drop induced by the plate and the force exerted on the plate are calculated as functions of the length of the plate. For the laminar flow, finite difference method (FDM) is used to obtain the vorticity and the stream function. When the Reynolds number exceeds a critical value, a pair of viscous eddies appears behind the plate.

  • PDF

Influence of Flow Conditions of Intake Air on Gas Flow Patterns in Engine Cylinder (흡기 유동 조건의 변화가 실린더 내 가스 유동 패턴에 미치는 영향)

  • 이창식;전문수;김우경;최수천
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.8
    • /
    • pp.17-23
    • /
    • 1999
  • This paper presents the characteristics of the gas flow in the engine cylinder under various intake flow conditins. The particle tracking velovimetry(PTV) was used to anlayze the gas flow pattern and flow field in the cylinder. Effects of tumble intensifying valve(TIV), swirl intensifying valve(SIV) and one-valve deactivated condition on in-cylinder flow patterns were compared with the baseline engine udner 600rpm motoring condition. In addtion, tumbel ration was estimated rwith results of in -cylinder flow fields. Base on experimental results, the tumble ration of in-cylinder flow field has the maximum value at the bottom dead center for the different four inlet conditions. In TIV condition, the tumble ration is 1.35 times larger than that of baseline engine and 1 intake valve deactivated condition is effective to improve in-cylinder swirl motion.

  • PDF

Reverse Flow Phenomena in a Circular Duct with an Obstruction at the Entry (원형 덕트 입구의 장애물이 있는 경우의 역류 유동 현상)

  • Zhang, Y.Z.;Sohn, C.H.;Gowda, B.H.L.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.36-41
    • /
    • 2006
  • Reverse flow (i.e. flow in the direction opposite to the free stream) inside a channel occurs when an obstruction is placed at certain positions near the near to the channel, placed in another wider channel. In this paper the reverse flow in a duct (diameter D) with an obstruction at the front (which is a disc), is investigated using PIV. The gap g between the obstruction and the entry to the duct is systematically varied and it is found that maximum reverse flow occurs at a g/D value of 0.5. The flow is stagnant around g/D of 1.25 and forward flow occurs for g/D values of 1.5 and above.

  • PDF

A Study on the Flow Characteristics of Rectangular Prism with Center Gap Through-flow at Different Aspect Ratio (중앙틈새를 관통하는 흐름을 갖는 사각형상 물체의 변장비에 따른 유동특성에 관한 연구)

  • Kim, Jin-Gu;Cho, Dae-Hwan;Han, Sang-Gook
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.25-30
    • /
    • 2011
  • Flow control of flow field is essential to design efficient elements relating to fluid machineries. In this study, flow characteristics of rectangular prism with center gap through-flow at different aspect ratio was investigated to flow control. It was used a FLUENT 6.3 version to study flow field. It was found that the through-flow disturbs the development of vertical velocity component and decreased the vortex size and critical value of a rapid change in pressure coefficient distribution.

The Effects of Task Value, Perceived Usefulness, and Teaching Presence on Learning Outcomes in Cyber University (사이버대학생의 학습성과에 대한 과제가치, 지각된 유용성, 교수실재감의 영향)

  • Lee, Jeong-Min;Yoon, Seok-In
    • Journal of The Korean Association of Information Education
    • /
    • v.15 no.3
    • /
    • pp.449-458
    • /
    • 2011
  • The purpose of this study is to investigate the effects of task value and perceived usefulness on learning outcomes. This study also examined the mediating effects of teaching presence in their relationships. As a result, task value and perceived usefulness significantly predicted learning outcomes (learning flow and learning persistence). In addition, teaching presence mediated between task value, perceived usefulness and learning outcome. This findings imply that task value, perceived usefulness, and teaching presence should be valued to enhance learning outcomes in Cyber university.

  • PDF