• 제목/요약/키워드: Flow Regulator

검색결과 120건 처리시간 0.026초

황색종 Bulk건조시 송풍량 조절에 따른 건조엽의 물리성 변화 (Effect of Air Flow During Curing Process on Physical Properties of Bulk Cured Leaves)

  • 이철환;진정의;한철수
    • 한국연초학회지
    • /
    • 제21권1호
    • /
    • pp.5-9
    • /
    • 1999
  • In recent years, the line of increase in policy on tobacco production triggered a rise in the loading volume per bulk curing barn, and manufacturers boosted the output of their blowers in order to prevent dirty leaves in the process of curing. for this reason, we studied the effect of the reducing air flow in bulk curing chamber from the color fixing stage to the stem drying stage of flue curing process on physical properties of cured leaves. The control of air flow was composed of the reducing air velocity of blower by means of a voltage regulator (slidac), and condition before color fixing stage was all the same with the conventional curing method. As a result, an effectiveness of improvement in the physical properties of cured leaves were observed. The leaves cured by this method were somewhat orange in color of upper stalk position, better bodied, and less brittle compared with the leaves produced by conventional curing. However, the leaves cured by this method had a little sharpness and harshness. As to the physical properties, there was decreased in occurrence of flat leaves than that of conventional ones. On the other hand, in case of reducing air flow during the curing process, increase of price per kg reached to about 5 % compared with those of conventional curing method.

  • PDF

UPFC의 동적 시뮬레이션 알고리즘 개발 (Development of Dynamic Simulation Algorithm of UPFC)

  • 손광명;김동현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.226-228
    • /
    • 1999
  • This paper presents a dynamic simulation algorithm for studying the effect of Unified Power Flow Controller(UPFC) on the low frequency power system oscillations and transient stability studies. The algorithm is a Newton-type one and gives a fast convergence characteristics. The algorithm is applied to inter-area power oscillation damping regulator design of a sample two-area power system. The results show that UPFC is very effective for damping inter-area oscillations.

  • PDF

Plasma control Using a Linear Quadratic Regulated RF Impedance Match Process

  • Kim, Byung-Whan;Park, Jang-Hyun;Park, Gwi-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.31.2-31
    • /
    • 2001
  • A real-time control strategy is presented for plasma control Rather than in-situ plasma variables, this is based on realtime measurements of two electrical positions that correspond to two match motors. Using the rf match monitor system, the positions were collected. The process of impedance matching was identified with variations in process factors, including rf power, pressure, and O$_2$ flow rate. A state-space model was obtained basing on autoregressive moving average model. For this model, a linear quadratic regulator was designed and applied. Simulation results revealed that match positions could accurately be regulated to follow certain positions arbitrarily chosen.

  • PDF

The computational characteristics of thrust and propellant mixture ratio regulators for LRE using a propellant combination of methane and oxygen

  • 주대성;남궁혁준;조용호;김경호;우유철
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2002년도 제19회 학술발표대회 논문초록집
    • /
    • pp.18-18
    • /
    • 2002
  • A project where the TPUs(Turbo Pump Units) for 10tf-thrust oxygen/methane LRE (Liquid Rocket Engine) are under development is being implemented to include an experimental combustion chamber developed. In the process of it, we introduced the power-balanced engine cycles in order to substantiate concepts of the engine using the combinations of the propellants. Accordingly, the main engine parameters of nominal operating mode are resulted from the 1-Dcalculations and it is found that the regulators are needed for controlling the expected pressure levels in the characteristics of propellant mixture ratio and thrust supposing the regulator is set to analogue-typed one which is easy to develop.The technical requirements like the nominal flow rate, its deviations expected and the pressure difference In need helped the several main characteristics of regulators to be determine in this stage. Here, a dozen of deviation values in the main parameters related to engineoperation are taken into independent consideration and accepted to the results for additional regimes of the regulators.Finally, we can determine the scheme and the primary dimensions along with the calculation design of the spring acceptable for general configuration which can definitely forwarded to the autonomous tests of the aggregates, The obtained data in further will be used for successive refinement of operating mode of the engine.

  • PDF

Phase Shift Control for Series Active Voltage Quality Regulators

  • Xiao, Guochun;Teng, Guofei;Chen, Beihai;Zhang, Jixu
    • Journal of Power Electronics
    • /
    • 제12권4호
    • /
    • pp.664-676
    • /
    • 2012
  • A phase shift algorithm based on the closed-loop control of dc-link voltage implemented on a series active voltage quality regulator (AVQR) is proposed in this paper. To avoid pumping-up the dc-link voltage, a general phase shift compensation strategy is applied. The relationships among the operation variables are discussed in detail, which is very important for guiding the design of both the main circuit and the control system. Then on the basis of an investigation of the dc-link voltage pumping-up from viewpoint of the active power flow, a novel phase shift control method based on the closed-loop of the dc-link voltage is proposed. This method can adjust the phase of the output voltage gradually and automatically according to the dc-link voltage variation without introducing a phase jump. The effectiveness of the proposed strategy is verified through simulations of a single-phase 5kVA prototype and laboratory experiments on both a single-phase 5kVA and a three-phase 15kVA prototype.

인체 유방암 세포에서 과다발현 시킨 Cyclin D2의 영향에 대한 연구 (Effect of Cyclin D2 on Cell Proliferation in T-47D Breast Cancer Cells)

  • 김현준;이근수;전상학;공구
    • 한국환경성돌연변이발암원학회지
    • /
    • 제24권1호
    • /
    • pp.1-9
    • /
    • 2004
  • Three D-type cyelins (D1, D2, and D3) are expressed in G1 phase of the cell cyele and have been implicated in cell transformation and neoplasia in human and mouse. Cyclin D1 overexpression or amplification was described in various human cancers. However, there is controversy about the role of cyclin D2 in cell cyele progression and human carcinogenesis. Specially, loss of cyelin D2 is involved in a vital tumor suppressor function in normal breast tissue, and that its loss may be related to tumorigenesis. The author examined to effect over-expression of cyclin D2 on the cell proliferation, apoptosis, and cell cycle using cyclin D2 transfected stable T47D breast cancer cells to investigate whether cyclinD2 functions as a positive regulator or negative regulator in cell proliferation. Overexpression of cyclin D2 led to the suppression of cell growth in cyclin D2 transfected T47D in both in its expression level and a time dependent manner with up to 50% reduction of cell growth at 72 hours. Therefore, the authors performed the cell cycle phase analysis using the flow cytometry to investigate the effect of cyclin D2 on the cell cycle phase in cyclin D2 transfected stable T47D cells. The flow cytometry analysis revealed increased sub G0 phase in cyclin D2 transfeted cells up to 23% at 72 hours. To confirm these results induced by overexpression of cyclinD2, the apoptotic bodies were counted in control and cyclin D2 transfected T47 cells. There are markedly increases of apoptotic bodies in cyclin D2-transfected cells up to 18%. These results suggested that Cyclin D2 suppresses the cell proliferation in breast cancers cells via the induction of apotosis.

  • PDF

Symmetrical Components를 이용한 배전계통 3상 조류 계산 알고리즘 개발 (Development of 3 phase Power Flow calculation algorithm in distribution Power Systems using Symmetrical Component)

  • 최정환;장성일;김광호;박종근;김재언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.147-149
    • /
    • 2000
  • This paper describes a power flow method for distribution systems, applying the method of symmetrical component to back/forward sweep method. The proposed algorithm is effective for unbalanced radial distribution system, with process of distributed resource(PQ & PV node), AVR(Auto Voltage Regulator), shunt capacitor. This proposed method compared conventional back/forward sweep method with the using three phase unbalanced distribution systems with 34 nodes.

  • PDF

대칭성분을 이용한 배전계통 조류 계산 알고리즘 개발 (Development of Power Flow calculation algorithm in distribution Power Systems using Symmetrical Components)

  • 최정환;정종찬;김광호;박종근;김재언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.401-403
    • /
    • 2001
  • This paper describes a power flow method for distribution systems, applying the method of symmetrical component to back/forward sweep method. The proposed algorithm is effective for unbalanced radial distribution system, with process of AVR(Auto Voltage Regulator), shunt capacitor. The proposed method was compared with the conventional Back/forward sweep method by using three phase unbalanced distribution systems of 123 nodes.

  • PDF

커먼레일 시스템용 저압 유압회로의 성능특성에 관한 연구 (A Study on the Performance Characteristics of Low Pressure Hydraulic Circuit of Common Rail System)

  • 이춘태
    • 동력기계공학회지
    • /
    • 제18권6호
    • /
    • pp.51-57
    • /
    • 2014
  • High pressure common rail injection technology has revolutionized the diesel industry. Over the last decade it has allowed engine builders to run higher injection pressures as much as above 1,300bar in order to increase engine efficiency, while reducing emissions. This common rail system has low pressure circuit which is consist of low pressure pump, cascade overflow valve and flow metering unit. The low pressure pump's purpose is to feed fuel oil to the high pressure pump. The cascade overflow valve keeps pressure in front of the metering unit constant and provides lubrication for the high pressure pump. The metering unit, known as the MPROP or fuel pressure regulator, regulates the maximum flow rate delivers to the rail. In this paper, we have investigated the performance characteristics of each components and total low pressure circuit of common rail system.

대칭성분을 이용한 3상 배전계통 조류계산 기법 (A New Distribution System Power Flow Method Using Symmetrical Components)

  • 최정환;정성일;박제영;김광호;김재언;박종근
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권1호
    • /
    • pp.15-22
    • /
    • 2002
  • This paper proposes a new power flow method for distribution system analysis by modifying the conventional back/forward sweep method using symmetrical components. Since the proposed method backward and forward sweeps with the variables expressed by symmetrical components, this method reduces computation time for matrix calculations; therefore, it is able to reduce the computational burden for real-time distribution network analysis. The proposed method was also developed to effectively analyze the unbalanced distribution system installing AVR(Auto Voltage Regulator), shunt capacitors. The proposed algorithm was compared with the conventional Back/forward Sweep method by applying both methods to three phase unbalanced distribution system of IEEE 123-bus model, and the test results showed that the proposed method would outperformed the conventional method in real-time distribution system analysis.