• 제목/요약/키워드: Flow Pattern

검색결과 2,305건 처리시간 0.026초

엘라스토머 사출성형시 CAE 유동해석과 실제 성형품의 비교 (Comparison of CAE Flow Analysis and Practical Molding on Elastomer Injection Molding)

  • 한성렬;김준형;전승경;이규호;정영득
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.375-376
    • /
    • 2006
  • Thermoplastic elastomer(TPE) can be molded by conventional injection molding. Therefore TPE injection molding could be analyzed by commercial flow analysis software. However there are a little of gaps on CAE simulation results and practical molding. In this study, the properties of TPE were measured and applied to CAE simulation for comparing the simulation flow pattern and real flow pattern. The pattern that was controlled by injection time was match. The pattern that was controlled by injection stroke and rate was not match.

  • PDF

냉장고 증발기 배관의 2상유동양식 예측 및 소음 평가 (Prediction of Two-phase Flow Patterns and Noise Evaluation for Evaporator Pipe in a Refrigerator)

  • 허소정;김민성;한형석;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제21권10호
    • /
    • pp.916-923
    • /
    • 2011
  • The refrigerant after the expansion valve interchanges the heat at the evaporator. At this moment, the state of gas and liquid becomes two-phase flow and causes irregular noise. In order to avoid the noise, the two-phase flow pattern should be predicted. In this paper, the procedure to predict the two-phase flow patterns such as churn flow and annular flow was suggested using the CFD software. The experiments using refrigerant-supplying equipment was carried out and the noise levels according to the flow pattern were measured. The flow patterns predicted by this procedure showed good agreement with those by experiments. The churn flow is noisier than annular flow pattern.

실 운전조건에서의 배기유동패턴이 근접장착 촉매변환기의 성능 및 신뢰성에 미치는 영향에 관한 수치적 연구 (Numerical Study on the Effect of Exhaust Flow Pattern under Real Running Condition on the Performance and Reliability of Closed-Coupled Catalyst)

  • 정수진;김우승
    • 한국자동차공학회논문집
    • /
    • 제12권2호
    • /
    • pp.54-61
    • /
    • 2004
  • The engine-out flow is highly transient and hot, and may place tremendous thermal and inertial loads on a closed-coupled catalyst. Therefore, time-dependent and detailed flow and thermal field simulation may be crucial. The aim of this study is to develop combined chemical reaction and multi-dimensional fluid dynamic mathematical model and to study the effect of unsteady pulsating thermal and flow characteristics on thermal reliability of closed-coupled catalyst. The effect of cell density on the conversion performance under real running condition is also investigated. Unlike previous studies, the present study focuses on coupling between the problems of pulsating flow pattern and catalyst thermal response and conversion efficiency. The results are expressed in terms of temporal evolution of flow, pollutant and temperature distribution as well as transient characteristics of conversion efficiency. Fundamental understanding of the flow and thermal phenomena of closed-coupled catalyst under real running condition is presented. It is shown that instants of significantly low values of flow uniformity and conversion efficiency exist during exhaust blowdown and the temporal varaition of flow uniformity is very similar in pattern to one of conversion efficiency. It is also found that the location of hot spot in monolith is directly affected by transient flow pattern in closed-coupled catalyst.

R-22 및 R-134a의 세관 내 유동 특성에 관한 연구 (Study on the Flow Characteristics of R-22, R-l34a in Small Diameter Tubes)

  • 홍진우;정재천;장승환;권옥배;오후규
    • 설비공학논문집
    • /
    • 제14권9호
    • /
    • pp.756-765
    • /
    • 2002
  • Experimental work was performed on the flow characteristics of R-22 and R-l34a in small diameter tubes. The experimental apparatus was made up of liquid pump, pre-heater, sight-glass, condenser and measurement instruments. The sight-glass for flow pattern observations was located at the outlet of the pre-heater. The experiment was carried out to show the flow characteristics of R-22 and R-l34a. Data were taken with test conditions in the following ranges; the mass flux was ranged from 100 to 1,000 kg/$m^2s$, the saturation temperature was $30^{\circ}C$ and the vapor quality was ranged from 0.1 to 0.9. The main results were summarized as follows; In the flow patterns during evaporation, the annular flow in a 2 mm inner diameter tube occurred at a relatively lower quality and mass velocity, compared to the flow in a 8mm inner diameter tube. The evaporation flow in small diameter tubes has been shown major deviations with the Mandhane, Taitel-Dukler's and Wambs-ganss' flow pattern maps but it was similar to the Dobson's flow pattern map.

형상 충전 기법을 이용한 자유표면의 비정상 점성 유동장의 유한 요소 해석 (Finite Element Analysis of Transient Viscous Flow with Free Surface using Filling Pattern Technique)

  • 김기돈;정준호;양동열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.551-556
    • /
    • 2001
  • The filling pattern technique based on the finite element method and Eulerian mesh advancement approach has been developed to analyze incompressible transient viscous flow with free surfaces. The governing equation for flow analysis is Navier-Stokes equation including inertia and gravity effects. The penalty and predictor-corrector methods are used effectively for finite element formulation. The flow front surface and the volume inflow rate are calculated using the filling pattern technique to select an adequate pattern among four filling patterns at each triangular control volume. Using the proposed numerical technique, the collapse of a dam has been analyzed to predict flow phenomenon of fluid and the predicted front positions versus time have been compared with the reported experimental result.

  • PDF

칩브레이커 형상변수에 의한 칩유동각 예측 (The Prediction of Chip Flow Angle on Chip Breaker Shape Parameters)

  • 박승근
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.381-386
    • /
    • 1999
  • In machining with cutting tool inserts having complex chip groove shape, the flow, curl and breaking patterns of the chip are different than in flat-face type inserts. In the present work, an effort is made to understand the three basic phenomena occurring in a chip since its formation in machining with groove type and pattern type inserts. These are the initial chip flow, the subsequent development of up and side curl and the final chip breaking due to the development of torsional and banding stresses. In this paper, chip flow angle in a groove type and pattern type inserts. The expression for chip flow angle in groove type and pattern type insets is also verified experimentally using high speed filming techniques.

  • PDF

수직상향 이상류에서 동심원관 간극이 유동양식과 보이드분포에 미치는 영향 (Effects of Annular Gap Size on the Flow Pattern and Void Distribution in a Vertical Upward Two-Phase Flow)

  • 손병진;김인석;김문철
    • 대한설비공학회지:설비저널
    • /
    • 제16권4호
    • /
    • pp.383-391
    • /
    • 1987
  • An experimental investigation has been conducted to determine the flow pattern for two-component , two-phase mixtures which flow vertically upwards in concentric annuli based on the measurement for the local void fraction and the distribution of the local void fraction in various radial locations in the annular gap. The annular test section consists of a lucite outer tube whose inside diameter is 38mm and a stainless steel rod, The rod diameter is either :2mm,16mm or 20mm. It is demonstrated that the probability density function of the fluctuations in void fraction may be used as an flow pattern indicator and the local void fraction distribution depends on the flow pattern and radial location in the annular passage.

  • PDF

AN IMPROVED ELECTRICAL-CONDUCTANCE SENSOR FOR VOID-FRACTION MEASUREMENT IN A HORIZONTAL PIPE

  • KO, MIN SEOK;LEE, BO AN;WON, WOO YOUN;LEE, YEON GUN;JERNG, DONG WOOK;KIM, SIN
    • Nuclear Engineering and Technology
    • /
    • 제47권7호
    • /
    • pp.804-813
    • /
    • 2015
  • The electrical-impedance method has been widely used for void-fraction measurement in two-phase flow due to its many favorable features. In the impedance method, the response characteristics of the electrical signal heavily depend upon flow pattern, as well as phasic volume. Thus, information on the flow pattern should be given for reliable void-fraction measurement. This study proposes an improved electrical-conductance sensor composed of a three-electrode set of adjacent and opposite electrodes. In the proposed sensor, conductance readings are directly converted into the flow pattern through a specified criterion and are consecutively used to estimate the corresponding void fraction. Since the flow pattern and the void fraction are evaluated by reading conductance measurements, complexity of data processing can be significantly reduced and real-time information provided. Before actual applications, several numerical calculations are performed to optimize electrode and insulator sizes, and optimal design is verified by static experiments. Finally, the proposed sensor is applied for air-water two-phase flow in a horizontal loop with a 40-mm inner diameter and a 5-m length, and its measurement results are compared with those of a wire-mesh sensor.

간흡충증 간염에서의 $^{99m}Tc-DISIDA$ 간담도스캔 (99mTc-DISIDA HEPATOBILIARY SCINTIGRAM IN EVALUATION OF CLONORCHIS SINENSIS INFESTATION IN ENDEMIC REGION)

  • 염하용
    • 대한핵의학회지
    • /
    • 제19권2호
    • /
    • pp.25-41
    • /
    • 1985
  • 간흡충증은 한국 및 동남아세아에 널리 분포되어 있는 중요한 풍토병의 하나로서 진단은 전통적으로 분변검사에 의존하여 오고 있다. 최근 들어 담관내 간흡충 및 이의 합병증의 진단을 위해 ERCP 및 contrast cholangiogram등이 시도되었으나 실제에 이용하기에는 많은 제약이 있다 하겠다. 저자는 간흡충증에 있어서 최근 소개된 $^{99m}Tc-DISIDA$ hepatobiliary scintigraphy의 진단적 의의를 규명하고자 1982년부터 1983년까지 고신의대 부속 복음병원에서 검진한 간흡충증 환자 90명을 대상으로 하여 $^{99m}Tc-DISIDA$ hepatobiliary scintigraphy와 formalin-ether 원침법에 의한 분변검사를 시행하였다. $^{99m}Tc-DISIDA$ scintigram소견은 간내 담관 bile flow 및 총수담관 bile flow defect, 그리고 간세포기능의 정도에 따라 자료를 분석하였고 그외 합병증의 진단은 병록 기록, 수술 소견, ERCP 등에 의존하여 결론을 얻었다. $^{99m}Tc-DISIDA$ scintigraphy는 특이한 양상의 bile flow dynamics를 나타내었으며 간내 주담관의 intermittent irregular focal bile flow defect 및 tile flow stasis를 나타내고 말초담관의 bile flow defect는 경미하고 60분 내에 담관 bile flow activity의 완전한 배설을 나타내는 경우를 mild pattern, 간내 담관의 심한 irregular bile flow dynamics 및 간내담관의 심한 irregularity (담관내벽의 심한 불규칙성), 총수담관, 간내 주담관 및 말초 담관까지 심하게 irregular bile flow stasis를 나타내며 bile flow activity의 완전 베설이 $60\sim90$분사이 혹은 90분이상까지 인지된 경우를 moderate-severe pattern으로 분류하였다. 1) 분변검사상 간흡충증은 95검사중 70검사(환자 86명중 67명)에서 양성을 보여 분변 충난검사의 양성율은 73.7%였고 음성율은 26.3%였다. 2) $^{99m}Tc-DISIDA$ hepatobiliary scintigraphy는 90명중 70명에서 특이한 Cs-bile flow양성을 보였으며 양성율은 77.8%였으며 음성율은 22.2%였다. 3) $^{99m}Tc-DISIDA$ hepatobiliary scintigram양성율을 나타낸 환자 70명중 11명은 mild pattern, 59명은 moderate-severe pattern을 나타냈으며 그중 21명은 여러가지 간세포 기능 및 담관에 영향을 미치는 질환과 합병했지만 특이한 Cs-bile flow pattern을 dominent하게 나타내었으며 합병된 여러 질환들도 bile flow pattern상 인지 할 수 있었다. 4) $^{99m}Tc-DISIDA$ hepatobiliary scintigram 음성율을 나타낸 환자 20명중 8명은 만성간염, 5명은 간경변증, 3명은 재발성 농양성담관염(recurrent pyogenic cholangitis)과 간내담도의 stricture 및 담관담석증이 합병되었으며 scintigram상 합병증의 pattern을 나타냈고 4명에서는 low CBD obstruction을 나타내었으며 후에 CBD stone, CBD carcinoma, gall bladder Ca.의 porta hepatis 전이 및 clonorchis worms의 cluster에 의한 obstruction이 operation 및 ERCP로서 진단 되었다. 5) $^{99m}Tc-DISIDA$ hepatobiliary scintigraphy pattern은 현재의 자각증상과 관계된 dominent disease를 나타내었으며, 공간 점유병소도 multiple project images를 시행하므로서 쉽게 발견할 수 있었다. 이와 같이 간흡충증에 있어서 $^{99m}Tc-DISIDA$ hepatobiliary scintigram은 환자의 자각증상과 관계된 질환을 규명하는 데 필요한 정보를 얻었을 수 있었으며 간내담관의 damage정도를 규명하는데 필요한 procedure임이 판명되었다.

  • PDF

Numerical Simulation: Effects of Gas Flow and Heat Transfer on Polymer Deposition in a Plasma Dry Etcher

  • Joo, Junghoon
    • Applied Science and Convergence Technology
    • /
    • 제26권6호
    • /
    • pp.184-188
    • /
    • 2017
  • Polymer deposition pattern on the ceramic lid surface is analyzed by numerical modeling. Assumption was made that is affected by gas flow pattern from the horizontal and vertical nozzles, temperature profile from the finger-like branches made of graphite and electrostatic potential effect. Calculated results showed gas flow dynamics is less relevant than two others. Temperature and electrostatic effects are likely determining the polymer deposition pattern based on our numerical simulation results.