• 제목/요약/키워드: Flow Measuring

검색결과 1,316건 처리시간 0.034초

프레스톤 튜브를 이용한 벽면전단응력 측정에 관한 실험적 연구 (Measurement of Wall Shear Stress Using Preston Tubes)

  • 강신형;윤민수;전우평
    • 대한기계학회논문집
    • /
    • 제18권7호
    • /
    • pp.1873-1880
    • /
    • 1994
  • Fully developed turbulent flow in a circular pipe and laminar boundary layer on a flat plate were measured to develop a measuring technique of the wall sheat stress using Preston tubes. New empirical formulas to extimate displacement factor of Preston tube obtained through the present study. The displacement factor for turbulent flow was considerably different from that for the laminar flow. Measured wall shear stress was not pretty dependent on the displacement factor for Preston tubes in the inertia sublayer of turbulent boundary layer, however was considerably affected in the laminar boundary layer. Measuring error of skin friction using the CPM technique was 3% for turbulent and 5% for thin laminar boundary layers.

배관 내 밸브 주위의 아이스슬러리의 유동현상 및 압력강하특성에 관한 연구 (An experimental study on ice slurry fluid and pressure drop characteristics in along a horizontal circular tube around the valve)

  • 오철;문성배;손용길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권3호
    • /
    • pp.382-388
    • /
    • 2006
  • This study experimented to understand the effect of transporting ice slurry through in pipe with valve. And at this experiment it used ethylene glycol-water solution and a concentration is 30wt%. The experimental apparatus was constructed of ice slurry generation tank, turbo flow meter, manometers for differential pressure measuring, PIV system for flow pattern measuring. illumination and along a horizontal circular tube with valve as test section. The experiments were carried out under various conditions, with velocity of fluid at the entry ranging from 0.5 to 1.5 m/s and concentration of IPF is 30%. Also valve open rate is 50%, 75%, 100%.

기체온도 측정을 위한 초음파 계측 (A ultrasonic technique for measuring gas temperature)

  • 최영;윤천한;전흥신
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1998년도 추계 학술발표회 논문집
    • /
    • pp.150-160
    • /
    • 1998
  • Measuring temperature with ultrasonic wave apparatus is desirable in the case of both below 300$0^{\circ}C$ and ideal gas because of the fact that the temperature of gas is the function of only sound velocity. In this study, being used a heatable wind channel and a blower, the variation of temperature is observed in accordance with diverse flow rate(air velocity). The frequency modulation method is used to measure the temperature which is varying in hot air flow till 10$0^{\circ}C$. The length changed in the position of ultrasonic sensors is considered. Also, the effects of air velocity at the same temperature and various facing angles of ultrasonic sensors are considered. As a result of this study, it has been found that the temperature in gas flow is correctly measured regardless of both the distance of ultrasonic sensors and the variation of air velocity, and that there is just a little influence of facing angles.

  • PDF

BTMSM/O2 유량변화에 따른 SiOCH 박막의 유전상수 특성 (Properties of SiOCH Thin Film Dielectric Constant by BTMSM/O2 Flow Rates)

  • 김종욱;황창수;김홍배
    • 한국전기전자재료학회논문지
    • /
    • 제21권4호
    • /
    • pp.362-367
    • /
    • 2008
  • We have Manufactured the low-k dielectric interlayer fabricated by plasma enhanced chemical vapor deposition (PECVD), The thin film of SiOCH is studied correlation between components and Dielectric constant. The precursor was evaporated and introduced with the flow rates from 16 sccm to 25 sccm by 1sccm step in the constant flow rate of 60 sccm $O_2$ in process chamber. The chemical characteristics of SiOCH were analyzed by measuring FT/IR absorption lines and obtained each dielectric constant measuring C-V. Then compare respectively. ILD of BTMSM/$O_2$ could have low dielectric constant about $k\sim2$, and react sensitively. Also dielectric constant could be decreased by the effects of decreasing $CH_3$ and growing Si-O-Si(C) after annealing process.

기체온도 측정을 위한 초음파 계측에 관한 연구 (A Study on Ultrasonic Technique for Measuring Gas Temperature)

  • 윤천한;최영;전흥신
    • 대한기계학회논문집B
    • /
    • 제23권7호
    • /
    • pp.893-900
    • /
    • 1999
  • Measuring temperature with ultrasonic wave apparatus is desirable in the cue of gas below $300^{\circ}$ because of the fact that the temperature of gas is the function of only sound velocity. In this study, being used a heatable wind channel and a blower. the variation of temperature is observed in accordance with flow rate(air velocity). The frequency modulation method is used to measure the temperature which is varying in hot air flow up to $100^{\circ}$. The length changed in the position of ultrasonic sensors is considered. Also. the effects of air velocity at the same temperature and various facing angles of ultrasonic sensors are considered. As a result of this study. it has been found that the temperature in gas flow is correctly measured regardless of both the distance of ultrasonic sensors and the variation of air velocity. and that there is just a little influence of facing angles.

LDV Measurement, Flow Visualization and Numerical Analysis of Flow Distribution in a Close-Coupled Catalytic Converter

  • Kim, Duk-Sang;Cho, Yong-Seok
    • Journal of Mechanical Science and Technology
    • /
    • 제18권11호
    • /
    • pp.2032-2041
    • /
    • 2004
  • Results from an experimental study of flow distribution in a close-coupled catalytic converter(CCC) are presented. The experiments were carried out with a flow measurement system specially designed for this study under steady and transient flow conditions. A pitot tube was a tool for measuring flow distribution at the exit of the first monolith. The flow distribution of the CCC was also measured by LDV system and flow visualization. Results from numerical analysis are also presented. Experimental results showed that the flow uniformity index decreases as flow Reynolds number increases. In steady flow conditions, the flow through each exhaust pipe made some flow concentrations on a specific region of the CCC inlet. The transient test results showed that the flow through each exhaust pipe in the engine firing order, interacted with each other to ensure that the flow distribution was uniform. The results of numerical analysis were qualitatively accepted with experimental results. They supported and helped explain the flow in the entry region of CCC.

슬라이드 밸브 급폐쇄에 따른 디스크 주위 비정상유동의 PIV계측에 관한 연구 (A Study on PIV Measurement of Unsteady Flow around Disk caused by Slide Type Valve Quick Closing)

  • 이철재;조대환
    • 해양환경안전학회지
    • /
    • 제15권3호
    • /
    • pp.251-256
    • /
    • 2009
  • 이 연구에서는 전 유동장의 순간속도를 계측 할 수 있는 PIV계측기법을 슬라이딩 밸브의 폐쇄 직후에 적용하고 짧은 시간에 발생하는 디스크 주위의 비정상 속도를 계측하여 유동특성을 실험적으로 고찰하였다. 순간유동장을 분석한 결과를 기존의 압력변동을 측정한 연구 결과에 비교 검토한 결과 슬라이드 밸브 급폐쇄에 따른 속도변동이 크게 나타나는 시간구간은 0.1초 이내이고 주기는 0.12초로 추정되었다. 또한 원관 내부의 디스크 주위유동은 상부부터 폐쇄되면서 유로가 좁아져 순간적으로 빠르게 하류로 진행하였으며 폐쇄직후에 역류하는 속도의 크기는 4/120초까지 감소하다가 다시 증가하는 경향을 보였다. 그리고 완전 폐쇄 후 상류 측으로 역류하는 흐름의 영향으로 y/D=0.2 하부 영역에 역류하는 속도성분이 나타났으며, y/D=0.7, x/D=-0.3의 근방에서 0.2D 크기의 회전와류가 관찰되었다.

  • PDF

승용차 모형주위의 유동에 관한 연구 (A study on flow around a passenger vehicle model)

  • 장성원;유정열;이택식
    • 오토저널
    • /
    • 제12권3호
    • /
    • pp.53-62
    • /
    • 1990
  • A wind tunnel experiment for the flow around a 1/5 scale passenger vehicle model has been carried out. A 5-hole Pitot tube is used for measuring velocity distributions around the model and a scanivalve with 48 ports is used for measuring surface pressure distribution at various Reynolds numbers. In order to observe the flow on the surface and in the wake region, a flow visualization experiment has been performed using wool tuft with and without paper cones. In addition, a 2-dimensional viscous calculation considering only the mid-plane section of the model has been performed. A complex wake structure in the immediate rear of the model has been confirmed. The distributions of the surface pressure coefficient are not sensitively dependent on the Reynolds Number. In the first half of the model, they do not seem to vary form section to section. However, in the second half, they do vary from section to section, especially at the bottom surface, which indicates that the cross flow vortex is more affected by the bottom surface than the top surface. The qualitative agreement of the measured and calculated velocity field also explains the usefulness of the 2-dimensional calculation in the limited sense.

  • PDF

Hybride PIV에 의한 단일입자/기포운동에 관한 연구 (Flow Characteristics in a Particle/Bubble Motion with Hybride PIV)

  • 최해만;사내강;문자수명;송정강일
    • 한국유체기계학회 논문집
    • /
    • 제5권1호
    • /
    • pp.7-12
    • /
    • 2002
  • As the first step to investigate the fundamental mechanism of a dispersed two-phase flow, we studied the detailed interactions between bubble or particle motion and flow around it. Experiments were carried out with a rising bubble or particle in stagnant water in a vertical pipe. Particles with different densities, and/or different shapes were used for comparison with a bubble. We adopted 3D-PTV (Three-Dimensional Particle Tracking Velocimetry) for measuring the bubble or particle motions, and PIV (Particle Image Velocimetry) for measuring the water flow simultaneously (Hybrid PIV). The experimental results showed that the oblate spheroidal solid particle rose along the longer axis direction at the point that the inclination of the longer axis reached the maximum, and the inclination direction changed after moving. The bubble moved to the direction that the spheroid's projected width grew up to the largest, and the minor axis of the oblate spheroidal body of the bubble was parallel to the moving direction. The trajectory of the center of the particle/bubble which was measured with 3D-PTV, was marked on the section (x-y) of the pipe. It exhibited the pattern of the particle/bubble motion.

낙동강수계 수질오염총량관리를 위한 유량조사 평가 (Evaluation on Actual Discharge Data for TMDL in Nakdong River Basin)

  • 김경훈;김용석;박배경;윤종수;신찬기
    • 환경위생공학
    • /
    • 제23권4호
    • /
    • pp.65-71
    • /
    • 2008
  • To drive efficiently total water pollution load management, needs to calculate the exact load emissions, pollution load allocation and implementation evaluation in each unit area of watershed and accurate and regular flow of data. For these reasons, the Nakdong River TMDL Research Center has produced directly or indirectly in the average interval of eight days (30 times or more / year) 41 points for unit area of the total water pollution load management and 8-point of municipal requirement for a total of 49 branches as a flow data in 2004 from August. This acquired the survey flow is evidence of trends and changes each point in the Nakdong River based on time, such as 10 years based on average design flow available to the foundation of the summit as the major water policy is to be utilized. This study was performed on actual discharge measuring data and introduced performance results each drainage basin of Nakdong River from 2004 to 2008 over the total of past five years.