• Title/Summary/Keyword: Flow Duct

Search Result 796, Processing Time 0.023 seconds

Study on the Ventilation System Applicability of High-rise Hog Building for Growing-fattening (고상식 육성비육돈사에 적합한 환기시스템에 관한 연구)

  • Yoo, Yong-Hee;Song, Jun-Ik;Choi, Dong-Yoon;Chung, Eui-Soo;Jeon, Kyoung-Ho;Lee, Poong-Yeon;Kim, Sang-Woo;Jeung, Jong-Won
    • Journal of Animal Environmental Science
    • /
    • v.16 no.1
    • /
    • pp.41-50
    • /
    • 2010
  • The goal of this study was to develop a suitable ventilation system for high-rise hog building (HRHB) for growing-fattening with combined slatted floor pen in second story and in situ manure management system in Korea. The HRHB was constructed as 29m long, 9m wide and 7.6m high for outer dimension with an indoor height of 3.1m and 2.4 for lower and upper floor, respectively. Ventilation systems for each treatment were installed in separated rooms of HRHB. The ventilation types installed in each room were following 3 types: ventilation type 1 (V1), where air was pulled through a circular duct inlet and exhausted by fans; ventilation type 2 (V2), where air was pulled through eave inlet (side ceiling inlet) and exhausted by fans; and ventilation type 3 (V3), where air was pulled through baffled ceiling inlet and exhausted by fans. For each ventilation system, investigated air velocity under minimum, medium and maximum ventilation ratio and air flow pattern inside. The results were as follows; For air flow pattern from top to bottom, V1 showed a homogeneous vertical type, V2 showed a bilateral symmetry type and V3 showed an vertical umbrella type. Under minimum ventilation ratio, air velocity in upper floor (80cm above the slated floor) was similar for V1, V2, and V3. Under maximum ventilation ratio, air velocity in upper floor was undeviating for V1 (0.10~0.26m/s) and varied for V2 (0.12~0.63m/s) while those for V3 was relatively slow and less varied (0.07~0.15m/s). In conclusion, Duct inlet type (V1) can be applied to the development of a new HRHB with additional evaluations such as field test hog feeding.

A study on the burn-in test to accomplish high quality cockpit air of an ultra-sonic aircraft in the early stage of production (생산 초기 초음속 항공기 조종석의 고품질 공기 확보를 위한 burn-in test 연구)

  • Shin, Jae Hyuk;Park, Sung Jae;Seo, Dong Yeon;Jeong, Suheon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.10
    • /
    • pp.871-876
    • /
    • 2016
  • Abnormal odor similar with burning smell often appears at the cockpit in the beginning of ultra-sonic aircraft without air filter due to the heating of production materials remained at the bleed air duct. Sources of the odor should be removed by burn-in test before test flight in order to prevent pilot confuses order with emergency such as fire of engine. However, the present method cannot prevent abnormal odor completely at the high altitude flight because maximum temperature of flight is higher than it of burn-in-test. This paper suggests burn-in test improved based on the analysis of thermal conditions of high altitude flight. It is verified that the existing burn-in test cannot cover thermal conditions of high altitude flight due to the discontinuous flow control, high change rate of temperature per unit time and difference between limit temperature of condenser and turbine. In order to overcome the limitations of current methods, the new burn-in test with continuous flow control are suggested. The continuous flow control are achieved by ram air inlet control. The effect of suggested method are verified by ground tests and flight tests. The results show the bleed air temperature can cover the temperature of high altitude flight and prevent abnormal odor at the flight test.

Numerical Study on Surface Air-Oil Heat Exchanger for Aero Gas-Turbine Engine Using One-Dimensional Flow and Thermal Network Model (항공기 가스터빈용 오일쿨러 해석을 위한 1 차원 열유동 네트워크 수치적 모델 개발 및 연구)

  • Kim, Young Jin;Kim, Minsung;Ha, Man Yeong;Min, June Kee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.11
    • /
    • pp.915-924
    • /
    • 2014
  • In an aero gas-turbine engine, a surface air-oil heat exchanger (SAOHE) is used to cool the oil system for the gearboxes and electric generators. The SAOHE is installed inside the fan casing of the engine in order to dissipate the heat from the oil system into the bypass duct stream. The purpose of this study was to develop an effective numerical method for designing an SAOHE for an aero gas-turbine engine. A two-dimensional model using a porous medium was developed to evaluate the aero-thermal performance of the fins of the heat exchanger, and a one-dimensional flow and thermal network program was developed to save time and cost in the evaluation of the heat exchanger performance. Using this network program, the pressure drop and heat transfer performance of the heat exchanger were predicted, and the results were compared with two-dimensional computational fluid dynamics results and experiment data for validation.

Design Guideline of Waveguide-Below-Cutoff Array for Electromagnetic Pulse Shielding (EMP 차폐 도파관의 형상 결정 가이드라인 작성)

  • Pang, Seung-Ki;Kim, Jae-Hun;Yook, Jong-Gwan;Kim, Yuna;Kim, Sangin
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.86-91
    • /
    • 2016
  • Convenient design guideline for Waveguide-below-cutoff (WBC) array is proposed to obtain the minimum waveguide length for electromagnetic pulse (EMP) shielding. The analysis includes circular, rectangular, and hexagonal WBC, determine the total length of the waveguide. When the unit side of rectangular WBC and the diagonal line of hexagonal WBC are given as 30 mm, the length of hexagonal WBC is 5 mm shorter than rectangular case with shielding effectiveness (SE) 80 dB. The length difference is deepened with SE of 100 dB, which shows approximately 30 mm shorter length for hexagonal case than others. In addition, hexagonal WBC requires much shorter length than circular WBC. In conclusion, hexagonal case is the most effective with respect to flow velocity and pressure loss for equivalent SE.

Analysis of Relative Contributions of Tonal Noise Sources in Volute Tongue Region of a Centrifugal Fan (원심팬 볼루트 영역내 순음 소음원의 상대적 기여도 분석)

  • Heo, Seung;Kim, Daehwan;Cheong, Cheolung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.1
    • /
    • pp.40-47
    • /
    • 2014
  • Interaction between the unsteady flow emitted from the blade of the centrifugal fan and the volute tongue region of fan duct is known as the main noise source of the centrifugal fan. In this paper, the relative contributions of the volute tongue region of the centrifugal fan is analyzed to utilize as the foundation data of low noise design. The internal hybrid CAA (Computational Aero-Acoustics) method is used to predict noise radiated from the main noise source. This method is the noise prediction technique using CFD (Computational Fluid Dynamics), Acoustic analogy, and BEM(Boundary Element Method). The relative contributions of the centrifugal fan volute tongue region using the hybrid CAA method show that the region between the cut-off and the scroll has high contribution than the region between the cut-off and the outlet and the hub region of blade has high contribution than the shroud region of blade. These results is utilized as the important data for the development of low noise centrifugal fan.

Enteral Infusion of Green Tea Extract Selectively Enhances the Biliary Secretion of 14C-Benzo[a]pyrene in Rats without Affecting Other Biliary Lipids

  • Noh, Sang-K.;Kim, Ju-Yeon
    • Preventive Nutrition and Food Science
    • /
    • v.16 no.2
    • /
    • pp.104-109
    • /
    • 2011
  • Recently, we have demonstrated that green tea extract (GTE) decreases the intestinal absorption of benzo[a]pyrene (BAP), which is an extremely lipophilic food contaminant. The present study was conducted to examine if an enteral infusion of GTE would influence the biliary secretion of BAP and lipids in rats. Female rats were fed an AIN-93G diet with or without (control) GTE at 5 g/kg diet for 4 week. Following the 4-week dietary treatment, rats with bile duct cannula were infused continuously for 8 hr at 3.0 mL/hr via a duodenal catheter with a lipid emulsion containing $4.0\;{\mu}mol$ BAP labeled with $^{14}C$ ($^{14}C$-BAP), $20.7\;{\mu}mol$ cholesterol, $452\;{\mu}mol$ triolein, and $3.1\;{\mu}mol$ ${\alpha}$-tocopherol, and $396.0\;{\mu}mol$ Na-taurocholate with or without 76.1 mg GTE powder in PBS buffer (pH, 6.4). Bile was collected hourly via bile cannula for an 8 hr period. Our results showed that bile flow did not differ between groups. However, the biliary secretion of $^{14}C$-BAP was significantly enhanced by GTE infusion, compared with those infused with the lipid emulsion alone. However, GTE did not affect the biliary outputs of cholesterol, fat, phospholipid and ${\alpha}$-tocopherol. These findings indicate that GTE has a profound stimulatory effect on the biliary excretion of BAP in rats, without affecting other biliary lipids. The mechanism(s) by which GTE enhances the biliary secretion of BAP remains to be investigated.

Optimization of Fugitive Dust Control System for Meteorological Conditions (기상조건별 비산먼지 관리체계 최적화 연구)

  • Kim Hyun-Goo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.6
    • /
    • pp.573-583
    • /
    • 2005
  • Fugitive dust, which is emitted in the ambient air without first passing through a stack or duct designed to control flow, is frequently generated by means of wind erosion from storage yards at Pohang Steel Wokrs. The size distribution of fugitive dust is mostly in the range of coarse particulate which is deposited as soon as emitted and less harm to human health; however $20\%$ of fugitive dust contains PM 10 known as one of most harmful airborne pollutant. Consequently, effective control and reduction of fugitive dust is strongly requested by the local society, but it is not easy so far because the generation and dispersion of fugitive dust highly depends on meteorological conditions, and it being occurred for irregularity. This research presented a fugitive dust control system for each meteorological condition by providing statistical prediction data obtained from a statistical analysis on the probability of generating the threshold velocity at which the fugitive dust begins to occur, and the frequency occurring by season and by time of the wind direction that can generate atmospheric pollution when the dispersed dust spreads to adjacent residential areas. The research also built a fugitive dust detection system which monitors the weather conditions surrounding storage yards and the changes in air quality on a real-time basis and issues a warning message by identifying a situation where the fugitive dust disperses outside the site boundary line so that appropriate measures can be taken on a timely basis. Furthermore, in respect to the spraying of water to prevent the generation of fugitive dust from the storage piles at the storage yard, an advanced statistical meteorological analysis on the weather conditions in Pohang area and a case study of fugitive dust dispersion toward outside of working field during $2002\∼2003$ were carried out in order to decide an optimal water-spraying time and the number of spraying that can prevent the origin of fugitive dust emission. The results of this research are expected to create extremely significant effects in improving surrounding environment through actual reduction of the fugitive dust produced from the storage yard of Pohang Steel Works by providing a high-tech warning system capable of constantly monitoring the leakage of fugitive dust and water-spray guidance that can maximize the water-spraying effects.

Pressure Recovery in a Supersonic Ejector of a High Altitude Turbofan Engine Testing Chamber (터보팬 엔진의 고고도 성능의 초음속 이젝터의 압력회복에 관한 연구)

  • Omollo, Owino George;Kong, Chang-Duk
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.6
    • /
    • pp.53-59
    • /
    • 2010
  • This research aims in finding a more optimal ejector size for evacuating engine exhaust gasses and 20% of the cell cooling air. The remaining 80% of cell cooling air pumped into the test chamber is separately exhausted from the test chamber via a discharge port fitted with flow control valves and vacuum pump. Unlike its predecessor this configuration utilizes a smaller capture area to improve pressure recovery. The modified ejector size has a diameter of 1100mm enough to evacuate 66kg/s jet engine exhaust in addition to about 20%, 24kg/s of the cell cooling air tapped from the sterling chamber. This configurations has an area ratio of the engine exit and ejector inlet of about 1.2. Simulation results of the proposed ejector configuration, indicates improved pressure recovery.

Better Housing for Effective Pig Production - Review -

  • Choi, H.L.;Song, J.I.;An, H.K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.8
    • /
    • pp.1310-1315
    • /
    • 1999
  • Air quality in confinement pig houses is important to production and health. Mechanical ventilation and confinement is known to be the most practical tool for maintaining adequate air quality in pig houses through extensive researches since Millier (1950) invented the 'slotted inlet' ventilation system. A variety of mechanical ventilation systems have been applied to confined nursery pig houses in Korea without scientific verification of their ventilation effectiveness. Ventilation systems with three feasible combinations (NA, NB, and NC) of inlets and outlets in a confined nursery pig house were tested to evaluate their ventilation efficiency, of which the one with the performance was supposed to be taken as a standard ventilation system for nursery pig houses in Korea. Field data of air velocity and temperature fields, and ammonia concentration with three ventilation systems were taken and compared to determine the best system. The air velocity and temperature fields predicted by the PHOENICS computer program were also validated against the available experimental data to investigate the feasibility of computer simulation of air and temperature distribution with an acceptable accuracy in a confined house. NC system with duct-induced in-coming air, performed best among the three different ventilation systems, which created higher velocity field and evener distribution ($2.5m/s{\pm}0.3m/s$) over the space with a Reynolds number of $10^4$. The experimental data obtained also fitted well with the simulated values using the modified PHOENICS, which suggested a viable tool for the prediction of air and temperature field with given calculation geometries.

A Numerical Study on the Performance Improvement of Kitchen Range Hood by Air Induction and Air Curtain (유도공기 및 에어커튼을 이용한 주방 레인지후드 성능 개선에 관한 수치모사)

  • Sohn, Deok-Young;Lim, Ji-Hong;Choi, Yun-Ho;Park, Jae-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.4
    • /
    • pp.321-327
    • /
    • 2007
  • In an apartment house that is generally air-tight and well insulated, the combustion gas from cooking devices is the major source of air pollution in the kitchen. It spreads throughout the house affecting the overall Indoor all quality. In this study, the performance of the kitchen range hood which employs air induction and air curtain was investigated by numerical simulation. The results are compared with that of two other kitchen range hoods which are in general use. The two general types of range hoods considered in the present calculations are box and plate type range hoods. The former has a large capture space between the filter and suction duct, while the latter has little. It was found that the capture efficiency of the kitchen range hood with air induction and air curtain Is higher than that of the general types of range hoods by 20% approximately The reason may be because the air induction and the air curtain block the air stream escaping from the front and the side part of range hoods effectively and because an additional fan for air induction and air curtain increases suction flow rates.