• 제목/요약/키워드: Flow Duct

Search Result 795, Processing Time 0.027 seconds

Numerical Simulation of Turbulent Flows in Inlet Duct of Heat Recovery Steam Generator (배열회수 안내덕트 내부의 난류유동 수치시뮬레이션)

  • Kwag, Seung-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.809-813
    • /
    • 2011
  • Turbulent flows are numerically simulated in the three dimensional inlet duct for heat recovery steam generator. The present study is aimed to analyze the effect of a variation in turbulent flow pattern by the change of roof angle in the transition duct. The finite volume based Navier-Stokes equations with unstructured grids are solved to make clear the flow dynamic phenomena. Reviews are made on with the data of path lines, velocity vectors, dynamic pressure, residuals for numerical convergence and so on. The k-epsilon, k-omega, Reynolds stress and RNG k-epsilon are used for generation of turbulence. Two types of roof angle are applied with and without the swirl in the duct. Turbulent flow patterns could be investigated for the optimum duct design based on the computational results.

Study of the Open End Correction of the Impulsive Wave Discharging from a Duct Exit (관출구로부터 방출하는 펄스파의 개구단 보정에 관한 연구)

  • 이동훈;김희동
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.7
    • /
    • pp.239-246
    • /
    • 2001
  • The present study addresses the open correction associated with the reflection and discharge phenomena of a weak shock wave from an open end of a duct. The open correction of the weak shock wave is investigated experimentally and by numerical computation. An experiment is made using a simple shock tube with an open end. and computaion is performed to simulate the experimental flow field using the unsteady, axisymmetric compressible. flow governing equations. The results obtained show the an open correction should be involved for shock wave discharge and reflection problems generated from the exit of the duct with an open baffle plate. With a baffle plate less than three times the duct diameter, it is found that the open end correction is a function of both the diameter of the baffle plate and normal shock wave magnitude However, for a baffle plate larger than three the duct diameter it is independent of the baffle plate diametre, The present computations predict the results of shock tube experiment with good accuracy. A new empirical equation for prediction of the open correction is found for the weak shock reflection and discharge phenomena occurring at the open of the duct with and without a baffle plate.

  • PDF

Balancing air flow at terminal in CAV duct system with DPM method (정풍량방식 덕트에서 이중압력측정방법을 이용한 취출구 풍량조정)

  • 이대우;박명식;박영우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.1
    • /
    • pp.66-78
    • /
    • 1998
  • Adequate ventilation with the proper amount of air to the right place is important factor to achieve a good Indoor air climate. Thus it is of prime importance that the ventilation system is working properly. This requires reliable pressure loss calculation to balance the air flow through duct systems. So a computer program for balancing CAV duct system is developed In this study. The results of CAV duct system is compared with the "Balans" code developed by Larsen from Norway. To obtain the pressure drop characteristics of damper at duct terminal, some experiments are performed using DPM(Dual Pressure Measurement) system. To adjust the resistance of damper, present study suggests that some special diffusers should be designed and damper producers should give the data of air flow vs. pressure drop to the customs when they manufacture the damper. One of the results concludes that the working time can be reduced from several minutes to several seconds per damper in the present experimental site, if the DPM system and the air volume adjusting process are used.

  • PDF

Optimal Shape Design of a 2-D Curved Duct Using a Mathematical Theory (수학적 이론을 이용한 이차원 곡면 덕트의 최적형상 설계)

  • Lim, Seokhyun;Choi, Haecheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.9
    • /
    • pp.1325-1334
    • /
    • 1998
  • The objectives of the present study are to develop a systematic method rather than a conventional trial-and-error method for an optimal shape design using a mathematical theory, and to apply it to engineering problems. In the present study, an optimal condition for a minimum pressure loss in a two-dimensional curved duct flow is derived and then an optimal shape of the curved duct is designed from the optimal condition. In the design procedure, one needs to solve the adjoint Navier-Stokes equations which are derived from the Navier-Stokes equations and the cost function. Therefore, a computer code of solving both the Navier-Stokes and adjoint Navier-Stokes equations together with an automatic grid generation is developed. In a curved duct flow, flow separation occurs due to an adverse pressure gradient, resulting in an additional pressure loss. Optimal shapes of a curved duct are obtained at three different Reynolds numbers of 100, 300 and 800, respectively. In the optimally shaped curved ducts, the separation region does not exist or is significantly reduced, and thus the pressure loss along the curved duct is significantly reduced.

A study on Flow Characteristics of the Semi-Circular inlet S-Shaped Intake at Various Angle of Incidence (입사각에 따른 반원형 입구형상 S-Shaped Intake에 대한 유동특성 연구)

  • Lee, Jihyeong;Cho, Jinsoo
    • Journal of Institute of Convergence Technology
    • /
    • v.5 no.2
    • /
    • pp.27-32
    • /
    • 2015
  • Air intakes are an essential component of aircraft engines. They are mainly used to offer uniform airflows to engine faces. Fighter aircraft have to mask the engine face inside the fuselage in order to reduce the Radar Cross Section(RCS). Therefore, offset intakes like a S-Duct are one of promising components for this purpose. During a fight, it is unavoidable that the flow will enter the intakes at some face angles other than zero. In this case, the performance of the aircraft engine will be influenced to the angle of incidence. In this study, the CFD analysis of the semi-circular S-Duct with AR(0.5,0) is performed to investigate the influence of the angle of incidence on the performance of the S-Duct using a distortion coefficient. To consider the adverse pressure gradient, a $k-{\omega}$ SST turbulence model is employed. The secondary flow and flow separation are observed for all computational cases. It is found that the positive incidence angle produces the best performances.

Numerical calculation of Laminar flow in a Square Duct of 90° Bend (정사각형 단면을 갖는 90° 곡관의 층류유동 계산)

  • Kim H. T.;Kim J. J.
    • Journal of computational fluids engineering
    • /
    • v.2 no.1
    • /
    • pp.1-7
    • /
    • 1997
  • A FA-FD hybrid method, developed for solving three-dimensional incompressible Navier-Stokes equations, is applied to calculate three-dimensional laminar flows through a square duct with a 90° bend. The method discretizes the convective terms in the primary flow direction with 3rd-order upwind finite-differences and the convective and diffusive terms in the transverse directions with the two-dimensional finite analytic method. The non-staggered grid system is used and the pressure-velocity coupling is achieved by a global iteration procedure based on the PISO algorithm. Detailed comparisons between the computed solutions and the available experimental data are given mainly for the velocity distributions at cross-sections in a 90° bend of a square duct with both fully developed and developing entry flows. Although the computational result shows generally a good agreement with the experimental data, there are some significant discrepancies underlining the necessity of more accurate numerical methods as well as reliable experimental data for their validation.

  • PDF

The Study on Changes of Exhaust Efficiency and Fine Particle Concentration at a Ventilation Opening by a Air Curtain Flow in a Subway Model Tunnel (지하철 모사터널에서 에어커튼을 이용한 환기구의 배기효율 및 미세입자 농도 변화 연구)

  • Han, Bang-Woo;Kim, Hak-Joon;Kim, Yong-Jin;Jeong, Sang-Hyeon;Kim, Yong-Min;Kim, Jong-Ryul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.614-622
    • /
    • 2011
  • In this study, a new tunnel ventilation method with a high velocity air curtain flow has been investigated for improving the ventilation exhaust efficiency and removing air pollutants in subway tunnels. At upper or lower position right downstream of a main duct connected with a ventilation opening, air curtain flows were suppled into the main duct where the air flow velocity was in the range of 2~6 m/s. Exhaust efficiency was monitored for both cases with and without air curtain flow for different air velocities, locations and injection angles of the air curtain. Particulate matter concentrations (PM10, PM2.5 and PM1.0) were also checked at both the main duct and ventilation opening before and after supplying air curtain flows. Lower air velocity of the main duct flow, higher air velocity of the air curtain led to higher exhaust efficiency and the air curtain condition of 30..inclined injection toward the main flow showed the maximum exhaust efficiency. The exhaust efficiency of about 24% without the air curtain could be improved to about 34% after using the air curtain flow. PM concentration decreased at the main duct and increased at the ventilation opening after using the air curtain flow. Therefore, the suggested method to use air curtain flows in tunnels will be probably one of the promising tools to reduce air pollutants in subway tunnels.

Study on Measurement and Numerical Analysis for Fluid Flow past a Circular Cylinder in Rectangular Duct (사각던트 내에서 원형 실린더를 지나는 유체유동의 측정 및 수치해석에 관한 연구)

  • 김경환;윤영환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.1095-1102
    • /
    • 2003
  • Flow characteristics of turbulent steady fluid flow past a cylinder in rectangular duct are measured by 5 W laser doppler velocity meter. The fluid flow is also computed by commercial software of STAR-CD for comparison between the measurement and computation. The turbulent models applied in the computations are standard K-epsilon model, RNG K-epsilon model and Chen K-epsilon model. Acurracy of standard K-epsilon model is a little bit better than acurracies of other models even though those models have almost the same order of error compared to measured data. The computations predict satisfactorily the measured velocity profiles at middle section of the circular cylinder before the fluid flow diverges. However, there are some disagreements between them at down stream from the circular cylinder.

Effect of Well Curvature on Curved Duct Flows

  • Hong Seung-Gyu;Heo Gi-Hun;Lee Gwang-Seop
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.131-135
    • /
    • 1997
  • Effect of wall curvature on flow characteristics is studied for mildly and strongly curved duct flows. The ducts are S-shaped, and the flow is partially blocked at the rear of the downstream. The presence of blockage in combination with curvature generates secondary flows on the concave surface; the magnitude of the secondary flow being dependent on the degree of wall curvature. Objectives are to compare the flow structures for mild and strong cases and to illuminate the changes in flow structure as the flow turns. Sensitivity on numerical solutions due to different inflow boundary conditions is also examined.

  • PDF

EFFECTS OF RIB ARRANGEMENTS AND ROTATION ON HEAT TRANSFER IN A ROTATING TWO-PASS DUCT (회전덕트에서 요철 배열 및 회전수 변화에 따른 열전달 특성)

  • Kim, Kyung-Min;Kim, Yun-Young;Lee, Dong-Ho;Cho, Hyung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2211-2218
    • /
    • 2003
  • The present study investigates heat/mass transfer characteristics in a rotating two-pass duct for smooth and ribbed surfaces. The duct has an aspect ratio of 0.5 and a hydraulic diameter of 26.67 mm. 70-angled rib turbulators are attached on the leading and trailing sides of the duct in parallel and cross arrangements. The pitch-to-rib height ratio is 7.5 and the rib height-to-hydraulic diameter ratio is 0.075. The Reynolds number based on the hydraulic diameter is constant at 10,000 and the rotation number ranges from 0.0 to 0.2 Detailed local heat/mass transfer coefficients are measured using a naphthalene sublimation technique. The results show that the secondary flows generated by the $180^{\circ}-turn$, rib turbulators, and duct rotation affect the wall heat/mass transfer distribution significantly, As the duct rotates, the rotaion-induced Coriolis force deflects the main flow and results in differences on the heat/mass transfer distribution between the leading and trailing surfaces. Its effects become more dominant as the rotaion number increases. Discussions are presented describing how the rib configuration and the rotaion speed affect the flow patterns and local heat/mass transfer in the duct.

  • PDF