• Title/Summary/Keyword: Flow Detection

Search Result 1,241, Processing Time 0.027 seconds

Rapid Acquisition of m-sequence Signals by Sequential Estimation with Flexible Structure (가변구조를 갖는 순차 예측 방법을 이용한 m 계열 신호의 고속 포착)

  • 현광민;박상규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.7B
    • /
    • pp.664-672
    • /
    • 2002
  • This paper analyzes a sequential estimator with flexible structure for rapid acquisition of the m-sequence signals. If the received PN chips stored in the estimator's internal registers as initial loading values include one error, this chip with error can be corrected through multiple local PN code generators to achieve high-speed acquisition performance. Hamming distance between regenerated local PN codes from the proposed system and received PN code is compared with given threshold to choose a possible correct path and to declare success of the code acquisition. Using signal flow graph, average acquisition time that depends on detection and false alarm probability is calculated. By modifying generally used matched filter structure for PN code acquisition, the proposed system provides flexible structure and rapid acquisition process.

The control system of sludge amount inspection and discharge materials of outlet water and affiliated water-purification tank (오수/합병정화조의 배출물 제어시스템 연구)

  • 박주식;김건호;오지영;임총규;강경식
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2001.11a
    • /
    • pp.193-202
    • /
    • 2001
  • The individual rotten water purification tank recently discharges wastewater and sewage through the outlet without purification ability. The outlet water and affiliated water purification tank with microorganism cultivator tank cultivates microorganism and then drops the value BOD, COD of sewage and discharges the quality of water into the outlet. The blower and water pump operating continuously prompts the waste of energy and deterioration of equipment. Each room of deposition tank, foaming tank, microorganism cultivator tank is equipment with the sludge detection senses so it can detect the density of each room. The power-drive plant of the blower and water pump which ate the system cultivating the microorganism must be made as fuzzy controlization (If the sludge amount of each room become higher, the rate of operation of blower and water pump must heighten, on the contrary, in case of row sludge amount, the total handling amount and microorganism handling amount of each room of control. Tank reducing the rate of operation must be DB. At present, the blower amount in proportion to the sludge and oxygen demanding amount has to control. Each mom must be checked outlet level of the outlet, also each room must flow backward discharge materials, and must operate feed-back control until we want to be come as a below value of BOD/COD(10PPM ; KS).

  • PDF

High-Performance Liquid Chromatographic Analysis of Chrysin Derivatives on A $Nova-Pak^{\circledR}C_{18}$ Column

  • Kim, Kyoung-Soon;Shin, Joon-Su;Park, You-Mie;Lee, Sanghyun;Kim, Yang-Bae;Kim, Bak-Kwang
    • Archives of Pharmacal Research
    • /
    • v.25 no.5
    • /
    • pp.613-616
    • /
    • 2002
  • A high-performance liquid chromatographic method has been developed for the separation and quantification of chrysin and synthetic chrysin derivatives (12 chrysin alkyl and 7 chrysin acyl derivatives). The chromatography was performed using a $Nova-Pak^{\circledR}C_{18}$ column. A RP-HPLC was performed by using a binary mixture (MeOH-10 mM H$_3$PO$_4$) as a mobile phase, and the column temperature was maintained at room temperature. A flow rate was 1.0 ml/min, and the effluent was monitored at a wavelenth of 280 nm. The retention times for chrysin acyl and alkyl derivatives were within 10 minutes and 20 minutes, respectively. The absolute recovery of samples were all over 96%. The detection limits were 0.1~18 ng at S/N = 3 ratio.

Chemiluminescence Determination of Balofloxacin Based on Europium (III)-Sensitized KBrO3-Na2S2O4 Reaction in Micellar Medium

  • Zhao, Fang;Qi, Yu;Xiong, Wei
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.1
    • /
    • pp.204-208
    • /
    • 2012
  • A novel chemiluminescence (CL) flow injection method for the determination of balofloxacin is described. The method is based on the weak CL signal arising from the reaction of $KBrO_3$ with $Na_2S_2O_4$ in acidic medium being significantly enhanced by balofloxacin in the presence of europium (III) ion and sodium dodecyl benzene sulfonate (SDBS). The experimental conditions that affected CL intensity were carefully optimized and the CL reaction mechanism was briefly discussed. Under the optimum conditions, the relative CL intensity was proportional to the concentration of balofloxacin in the range of $7.0{\times}10^{-11}$ to $3.0{\times}10^{-7}g\;mL^{-1}$. The detection limit was $2.7{\times}10^{-11}g\;mL^{-1}$ and the relative standard deviation was 2.1% for $7.0{\times}10^{-10}g\;mL^{-1}$ balofloxacin (n = 13). The proposed method was successfully applied to the determination of balofloxacin in pharmaceutical formulations and biological fluids.

Quantitative and Pattern Recognition Analyses for the Quality Evaluation of Magnoliae Flos by HPLC

  • Fang, Zhe;Shen, Chang Min;Moon, Dong-Cheul;Son, Kun-Ho;Son, Jong-Keun;Woo, Mi-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.11
    • /
    • pp.3371-3381
    • /
    • 2010
  • In this study, quantitative and pattern recognition analysis for the quality evaluation of Magnoliae Flos using HPLC/UV was developed. For quantitative analysis, eleven major bioactive lignan compounds were determined. The separation conditions employed for HPLC/UV were optimized using ODS $C_{18}$ column ($250{\times}4.6\;mm$, $5\;{\mu}m$) with isocratic elution of acetonitrile and water with 1% acetic acid as the mobile phase at a flow rate of 1.0 mL/min and a detection wavelength of 278 nm. These methods were fully validated with respect to the linearity, accuracy, precision, recovery, and robustness. The HPLC/UV method was applied successfully to the quantification of eleven major compounds in the extract of Magnoliae Flos. The HPLC analytical method for pattern recognition analysis was validated by repeated analysis of twenty one reference samples corresponding to seven different species of Magnoliae Flos and nine samples purchased from market. The results indicate that the established HPLC/UV method is suitable for the quantitative analysis and quality control of multi-components in Magnoliae Flos.

Determination of Free Amino Acids in Isatidis Radix By HILIC-UPLC-MS/MS

  • Pan, Yilin;Li, Jin;Li, Xiang;Chen, Jianwei;Bai, Ganggang
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.1
    • /
    • pp.197-203
    • /
    • 2014
  • A rapid, accurate and precise method for the determination of 22 amino acids in Isatidis Radix by Hydrophilic Interaction Ultra-High-Performance Liquid Chromatography Coupled with Triple-Quadrupole Mass Spectrometry (HILIC-UPLC-MS/MS) was established. Chromatographic separation was carried out on a Acquity UPLC BEH Amide column ($2.1mm{\times}100mm$, $1.7{\mu}m$) with gradient elution of acetonitrile (containing 0.05% formic acid and 2 mM ammonium formate) and water (containing 0.15% formic acid and 10 mM ammonium formate) at a flow rate of 0.4 mL/min; Waters Xevo$^{TM}$ TQ worked in multiple reaction monitoring mode. All components were separated in 17 min. All calibration curves were linear ($R^2$ > 0.991) over the tested ranges. The limits of detection (LOD) and limits of quantitation (LOQ) for these compounds were 0.21-79.55 and 0.72-294.23 ng/mL, respectively. The average recoveries were in the range of 93.75-104.16% with RSD value less than 6.56%. Therefore, this method could be an alternative assay for the determination of 22 amino acids in Isatidis Radix due to its rapidness, sensitivity, less sample and solvent consumption.

ON-POWER DETECTION OF PIPE WALL-THINNED DEFECTS USING IR THERMOGRAPHY IN NPPS

  • Kim, Ju Hyun;Yoo, Kwae Hwan;Na, Man Gyun;Kim, Jin Weon;Kim, Kyeong Suk
    • Nuclear Engineering and Technology
    • /
    • v.46 no.2
    • /
    • pp.225-234
    • /
    • 2014
  • Wall-thinned defects caused by accelerated corrosion due to fluid flow in the inner pipe appear in many structures of the secondary systems in nuclear power plants (NPPs) and are a major factor in degrading the integrity of pipes. Wall-thinned defects need to be managed not only when the NPP is under maintenance but also when the NPP is in normal operation. To this end, a test technique was developed in this study to detect such wall-thinned defects based on the temperature difference on the surface of a hot pipe using infrared (IR) thermography and a cooling device. Finite element analysis (FEA) was conducted to examine the tendency and experimental conditions for the cooling experiment. Based on the FEA results, the equipment was configured before the cooling experiment was conducted. The IR camera was then used to detect defects in the inner pipe of the pipe specimen that had artificially induced defects. The IR thermography developed in this study is expected to help resolve the issues related to the limitations of non-destructive inspection techniques that are currently conducted for NPP secondary systems and is expected to be very useful on the NPPs site.

Residual determination of Ceftiofur in Raw Bovine Milk by Liquid Chromatography-Electrospray Mass Spectrometry

  • Lim, Jong-hwan;Park, Byung-kwon;Kim, Myoung-seok;Jang, Beom-Su;Kim, Doo;Yun, Hyo-in
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.3
    • /
    • pp.367-371
    • /
    • 2004
  • This report describes the determination of ceftiofur residues in milk from treatment of lactating dairy cattle by intramuscular injection of three consecutive daily doses of about 1 mg /kg BW, the recommended label dosing. The separation of ceftiofur was achieved on $C_1_8$ reverse phase column. The mobile phase consisted of 0.1% trifluoracetic acid in water (A) and 0.05% acetic acid in acetonitrile (B) and grediently flowed at the flow rate of 0.4 mL/min. As a result of analysis of blank raw bovine milk samples, matrix interference was not shown. Limit of detection and limit of quantitaion was 0.5 ng/mL and 1 ng/mL, respectively. The values of precision and recovery satisfied the guideline of National Veterinary Research and Quarantine Service (NVRQS, Korea). The mean residual concentration of ceftiofur in milk did not exceed 3.71 ng/mL when ceftiofur was administered intramuscularly to lactating dairy cattle for 3 consecutive days at 1 mg/kg of BW per day. It is much lower than the proposed MRL (100 ng/mL) of ceftiofur in milk.

Derivation of Optimal Design Flood by Gamma and Generalized Gamma Distribution Models(I) - On the Gamma Distribution Models - (Gamma 및 Generalized Gamma 분포 모형에 의한 적정 설계홍수량의 유도 (I) -Gamma 분포 모형을 중심으로-)

  • 이순혁;박명근;정연수;맹승진;류경식
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.3
    • /
    • pp.83-95
    • /
    • 1997
  • This study was conducted to derive optimal design floods by Gamma distribution models of the annual maximum series at eight watersheds along Geum , Yeong San and Seom Jin river Systems, Design floods obtained by different methods for evaluation of parameters and for plotting positions in the Gamma distribution models were compared by the relative mean errors and graphical fit along with 95% confidence interval plotted on Gamma probability paper. The results were analyzed and summarized as follows. 1.Adequacy for the analysis of flood flow data used in this study was confirmed by the tests of Independence, Homogeneity and detection of Outliers. 2.Basic statistics and parameters were calculated by Gamma distribution models using Methods of Moments and Maximum Likelihood. 3.It was found that design floods derived by the method of maximum likelihood and Hazen plotting position formular of two parameter Gamma distribution are much closer to those of the observed data in comparison with those obtained by other methods for parameters and for plotting positions from the viewpoint of relative mean errors. 4.Reliability of derived design floods by both maximum likelihood and method of moments with two parameter Gamma distribution was acknowledged within 95% confidence interval.

  • PDF

A Study on A New Two-Dimensional Pulsed Doppler System Using Second-Order Sampling Method. (2차 샘플링을 이용한 새로운 초음파 2차원 펄스 도플러 시스템에 관한 연구)

  • Park, Se-Hyeon;Im, Chun-Seong;Kim, Yeong-Gil
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.1
    • /
    • pp.33-42
    • /
    • 1989
  • The doppler effect is used for measuring the velocity of the blood flow in artery. Because of the range information, the pulsed doppler system is most commonly used. In this paper, we propose a new two-dimensional(2-D) pulsed Doppler system. Which uses second-order sampling method and serial processing. The proposed system using second-order sampling method eliminates in-phase, quadrature-phase balancing problem at demodulator of quadrature detection method. In addition, the new pulsed 2-D doppler system eliminates balancing problem of channels of 2-D doppler system because of serial processing.

  • PDF