Browse > Article
http://dx.doi.org/10.5516/NET.04.2013.078

ON-POWER DETECTION OF PIPE WALL-THINNED DEFECTS USING IR THERMOGRAPHY IN NPPS  

Kim, Ju Hyun (Department of Nuclear Engineering, Chosun University)
Yoo, Kwae Hwan (Department of Nuclear Engineering, Chosun University)
Na, Man Gyun (Department of Nuclear Engineering, Chosun University)
Kim, Jin Weon (Department of Nuclear Engineering, Chosun University)
Kim, Kyeong Suk (Department of Mechanical Design Engineering, Chosun University)
Publication Information
Nuclear Engineering and Technology / v.46, no.2, 2014 , pp. 225-234 More about this Journal
Abstract
Wall-thinned defects caused by accelerated corrosion due to fluid flow in the inner pipe appear in many structures of the secondary systems in nuclear power plants (NPPs) and are a major factor in degrading the integrity of pipes. Wall-thinned defects need to be managed not only when the NPP is under maintenance but also when the NPP is in normal operation. To this end, a test technique was developed in this study to detect such wall-thinned defects based on the temperature difference on the surface of a hot pipe using infrared (IR) thermography and a cooling device. Finite element analysis (FEA) was conducted to examine the tendency and experimental conditions for the cooling experiment. Based on the FEA results, the equipment was configured before the cooling experiment was conducted. The IR camera was then used to detect defects in the inner pipe of the pipe specimen that had artificially induced defects. The IR thermography developed in this study is expected to help resolve the issues related to the limitations of non-destructive inspection techniques that are currently conducted for NPP secondary systems and is expected to be very useful on the NPPs site.
Keywords
IR Thermography; Wall-thinned Defects; IR Camera; Cooling Device; Finite Element Analysis (FEA); On-power Inspection;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 M. Frank, R. Hans, and S. Helmut, "Experience with piping in German NPPs with Respect to Ageing-Related Aspects," Nucl. Eng. & Des., vol. 207, pp. 307-316 (2001).   DOI   ScienceOn
2 K. S. Kim, H. S. Chang, D. P. Hong, C. J. Park, S. W. Na, K. S. Kim, and H. C. Jung, "Defect Detection of the Wall Thinning Pipe of the Nuclear Power Plant Using Infrared Thermography," Journal of the Korean Society for Nondestructive Testing, vol. 30, pp. 85-90 (2010).   과학기술학회마을
3 G. Shen and T. Li, "Infrared thermography for high-temperature pressure pipe," Insight, vol. 49, pp. 151-153 (2007).   DOI
4 C. J. Hellier, "Handbook of nondestructive evaluation," McGraw-Hill, 2nd Ed. (2001).
5 A. Vageswar, K. Balasubramanian, C. V. Krishnamurthy, T. Jayakumar, and B. Raj, "Periscope infrared thermography for local wall thinning in tubes," NDT&E International, vol. 42, pp. 275-282 (2009).   DOI   ScienceOn
6 J. M. Lloyd, "Thermal Imaging Systems," Plenum press (1979).
7 S. V. Patankar, "Numerical Heat Transfer and Fluid Flow," Hemisphere Pub. Co. (1980).
8 H. D. Lee, "Thermal measurement theory using infrared camera," Journal of KSNVE, vol. 17, pp. 31-34 (2007).
9 X. P. V. Maldague and P. O. Moore, "Nondestructive Testing Handbook: Infrared and Thermal Testing," American Society for Nondestructive Testing, vol. 3, 3rd Ed., pp. 223-246 (2001).
10 ANSYS, ANSYS 13.0 (Release 13.0), ANSYS Inc. (2010).
11 Fluent, GAMBIT 2.1, Fluent Inc. (2003).
12 P. K. Rastogi and D. Inaudi, "Trends in Optical Nondestructive Testing and Inspection," Elsevier Science (2000).