• Title/Summary/Keyword: Flow Control Valve

Search Result 702, Processing Time 0.03 seconds

Detection of Leakage Point via Frequency Analysis of a Pipeline Flow

  • Kim, Sanghyun;Wansuk Yoo;Injoon Kang
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.232-238
    • /
    • 2001
  • Fast Fourier Transformation is employed to convert the head variation of a pipeline in the time domain to the amplitude of the frequency domain. Applying method of characteristics to a pipeline provides a significant frequency range for a surge introduced from the valve modulation. Inverse Fast Fourier Transformation and a Finite Impulse Response Filter can be used to remove any possible noise existing from the significant frequency range of an unsteady condition. A filtered signal shows higher potential for the inverse calculation of leakage detection than the noise-added signal does. The respective performances of Inverse Fast Fourier Transformation and a Finite Impulse Response Filter are compared in terms of leakage detection capability. Characteristics of the frequency range for multiple leakages were investigated to validate the effectiveness of the noise control method in the frequency domain.

  • PDF

Investigation on Transient Vibration of Piping System to Heater in a Power Plant (발전소 가열기 급수용 배관계 이상 진동 고찰)

  • 양경현;조철환;배춘희
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.975-978
    • /
    • 2004
  • There was transient vibration on the piping system from #4 heater to the deaerator in a power plant. We found it was resulted from resonance between the natural vibration of the piping system and vibration induced by flow of feedwater. We verified it would reduce vibration by increasing stiffness of the piping system. Therefore we concluded that it would be generally better to increase stiffness of the piping system to reduce vibration amplitude of 10Hz low for big sized piping systems.

  • PDF

Development of Injection-Type Olfactometer (직접 분사식 후각기의 개발)

  • 송준수;이홍교;송성호;양경헌
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.245-245
    • /
    • 2000
  • 후각기는 후각신경과 삼차신경의 기능을 객관적이고 정량적으로 검사할 수 있는 기기로, 객관적으로 인정받을 수 있는 후각기의 제작에는 많은 어려움이 있기 때문에, 현재까지 후각신경과 삼차신경의 기능을 정확하게 측정할 수 있는 방법이 없었다. 그러나, 산업이 발달하고 공해가 더욱 심해질수록 후각의 변화가 생기고, 비강 내 질환이나, 공해물질 등에 의해 삼차신경이 민감한 반응을 일으키므로, 앞으로는 이 신경들의 측정이 중요할 것으로 여겨진다. 또한 각종 산업분야에서 이제까지 사람의 미각이나 후각에 의존하여 제품을 생산해오던 방법을 변화시켜 객관적인 수치를 이용하여 제품을 생산할 수 있다. 따라서 이번 연구에서는 사람이나 동물에게 다양한 후각물질을 원하는 정확한 농도로 투여하는 기기로, 온도와 습도를 사람의 신체 조건과 동일한 공기와 혼할하여 원하는 정확한 농도(ppm)의 후각 자극을 만들어 mass flow controller와 solenoid valve를 이용하여 square-shape의 자극모양이 되도록 한 후, 피검자에게 자극하여 전기생리학적 반응을 얻는 기기를 개발하였다.

  • PDF

A Numerical Study on the Reduction of Water Hammering in a Simple Water Supply Pipe System

  • Lim, Ki-Won;Cha, Dong-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.2
    • /
    • pp.51-61
    • /
    • 2001
  • A numerical study has been conducted to characterize the transient pressure in a simple water supply pipe system with an air chamber by utilizing a commercial code that employs the method of characteristics. Some results produced for validation in the study agree quite well with the previously reported. Several parameters are than varied. Among them are the valve closure time, the wave speed, the static pressure, the polytropic exponent, the air chamber volume, the diameter and the shape of orifice in the air chamber, etc, while the water temperature and velocity are kept constant at $20^\circ{C}$ and 0.8m/s, respectively. Results reported in this parametric study may be useful to understand the unsteady behavior of the system.

  • PDF

Energy Performance Analysis Program with Heating methods of Automatic Thermostatic Valves in Floor Radiant Heating System (바닥난방용 자동온도조절기의 난방방식에 따른 에너지성능 해석용 프로그램에 관한 연구)

  • Ahn, Byung-Cheon;Song, Jae-Yeob;Lee, Tae-Won;Kim, Yong-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.381-386
    • /
    • 2008
  • In this study, the energy characteristic of automatic thermostatic valves according to each heating method in floor radiant heating system were researched by computer simulation. For the analysis of unsteady heat transfer phenomena in household, the method of using electrical equivalent R-C circuit is applied, and radiation heat transfer between panel, ceiling and walls in household is calculated by enclosure analysis method. The parametric study on heating method, valve's control method, outdoor air condition, supply heating water temperature, supply flow rate are performed to compare energy characteristic, respectively.

  • PDF

A Study on the Performance Analysis of Proportional Automatic Thermostatic Valves in Floor Radiant Heating System (바닥난방 시스템용 비례식 자동온도조절밸브의 성능해석에 관한 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon;Kim, Yong-Ki;Lee, Tae-Won
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.52-57
    • /
    • 2007
  • The control characteristics for radiant panel heating system with automatic thermostatic valves were researched by computer simulation and experiment. The unsteady energy analysis using equivalent R-C circuit method and radiation heat transfer analysis of enclosure analysis method with simple structured rooms was performed. The results of flow rate changes of the simulation study are good fit with the ones of experimental one.

  • PDF

Performance Analysis of Carbon Canister for Reducing Evaporative Emissions in a Gasoline Automotive Engine

  • Chung, Yon-Jong;Cho, Gyu-Sang;Erickson, Paul A.;Han, Sung-Bin
    • Journal of Energy Engineering
    • /
    • v.17 no.2
    • /
    • pp.47-53
    • /
    • 2008
  • The objective of this paper is to clarify the flow characteristic, velocity distribution, pressure loss, and other such fundamental data for the canister during loading and purging. The amount of gas that is loaded increases as the loading rate is decreased and the time increased, and the purging improves as the purge rate is increased. The hydrocarbons that are purged initially have a high concentration, and a large amount is purged. During loading and purging, the temperature initially increases and decreases drastically due to heat generation and heat loss.

Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 3: Mounting and operating conditions for in-line valves and appliances (급수기구 발생음의 실험실 측정방법 제3부 : 직렬 밸브와 급수기구의 설치방법 및 작동조건)

  • Jeong, G.C.;Yang, K.S.;Park, H.G.;Kim, S.W.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.986-989
    • /
    • 2004
  • The method of measurement for laboratory tests on noise emission from appliances and equipment used in water supply installations is specified in ISO 3822-1 This part of standard gives detailed descriptions for mounting and operating in-line valves and appliances, which control the flow, pressure or temperature of the water in water supply installations in such laboratory tests.

  • PDF

Effects of Open Area Ratio of Secondary Injection Flow Valve on Thrust, Side Thrust and Roll Moment of Solid Rocket Motor (2차분사 유량 조절 밸브 개도가 고체 로켓 모터의 추력, 측추력 및 롤 모멘트에 미치는 영향)

  • Kim, Sang-Min;Hwang, Yong-Sok;Yoon, Woong-Sup
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.225-229
    • /
    • 2012
  • 대기가 희박한 고고도 환령이나 급격한 선회를 위해 2차분사에 의한 추력벡터제어를 사용한다. 8개의 2차분사구를 갖는 고체로켓모터를 대상으로, 2차분사의 유량을 조절하는 밸브의 개도가 추력, 측추력 및 롤 모멘트에 미치는 영향을 해석적으로 연구하였다. 정상 상태의 3차원 Reynolds Averaged Navier-Stokes 식의 해를 구하였으며, 난류를 위해 Spalart-Almaras 모델을 사용하였다. 수치해석의 타당성을 평가하기 위해 실험 결과와 해석결과를 비교하였다. 밸브의 개도가 증가함에 따라 추력은 감소하나 측추력은 증가한다. 반면, 롤 모멘트의 경우, 밸브와 2차분사 파이프의 상호작용에 의해 개도에 비례하지 않는다.

  • PDF

A Study on the Flow Characteristics of a Swash-Plate Piston-Pump Inlet (사판식 피스톤 펌프 흡입구의 유동 특성에 관한 연구)

  • Lee, Jeong-Sil;Jun, Cha-Soo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.10
    • /
    • pp.56-62
    • /
    • 2021
  • In this study, a cavitation occurrence in a piston-pump inlet was investigated by simulating the pressure distribution, according to the inlet shape of a variable-displacement swash-plate piston pump that supplies high-pressure oil to control the hydraulic system of a marine engine. Two types of pump inlets with different shapes were cast into impression models, and the models were reverse-engineered by 3D scanning. Then, the hydraulic-pressure distribution was analyzed through finite-element analysis. The results of the analysis confirmed that cavitation occurs more easily in the inlet with a steeper slope during pump operation because the inlet pressure on the valve plate is lower than that of the other pump with a gentler inlet slope.