• Title/Summary/Keyword: Flow Chart

Search Result 260, Processing Time 0.029 seconds

CCD Image Sensor with Variable Reset Operation

  • Park, Sang-Sik;Uh, Hyung-Soo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.3 no.2
    • /
    • pp.83-88
    • /
    • 2003
  • The reset operation of a CCD image sensor was improved using charge trapping of a MOS structure to realize a loe voltage driving. A DC bias generating circuit was added to the reset structure which sets reference voltage and holds the signal charge to be detected. The generated DC bias is added to the reset pulse to give an optimized voltage margin to the reset operation, and is controlled by adjustment of the threshold voltage of a MOS transistor in the circuit. By the pulse-type stress voltage applied to the gate, the electrons and holes were injected to the gate dielectrics, and the threshold voltage could be adjusted ranging from 0.2V to 5.5V, which is suitable for controlling the incomplete reset operation due to the process variation. The charges trapped in the silicon nitride lead to the positive and negative shift of the threshold voltage, and this phenomenon is explained by Poole-Frenkel conduction and Fowler-Nordheim conduction. A CCD image sensor with $492(H){\;}{\times}{\;}510(V)$ pixels adopting this structure showed complete reset operation with the driving voltage of 3.0V. The resolution chart taken with the image sensor shows no image flow to the illumination of 30 lux, even in the driving voltage of 3.0V.

The Design Flowchart of Earthing System for Building Electrical Installations in Accordance with International Standards (국제표준에 따른 건축전기설비의 접지시스템 설계순서)

  • Lee, Ju-Cheol;Yeom, Jin-Geun;Jeong, Seung-Hyun;Byeon, Cheol-Gyun;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.8
    • /
    • pp.113-120
    • /
    • 2014
  • In this paper, designing of an earthing system in accordance with international standards with regard to 22.9kV-y multi-grounded neutral system is discussed and confirmed that the consumer's earthing system can be a part of a global earthing system by interconnecting its earthing system with the neutral conductor of 22.9kV-y multi-grounded system. Further, it is proposed that some modification of the earthing system design flowchart given in the international standards are necessary when considering the equipotential bonding, lightning protection, and telecommunications facilities as well as the basic safety requirements.

An Improved Central 60° Synchronous Modulation for High Transient Performance with PMSM Stator Flux Control Used in Urban Rail Transit Systems

  • Fang, Xiaochun;Lin, Fei;Yang, Zhongping
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.542-552
    • /
    • 2016
  • Central 60° synchronous modulation is an easy pulse-width modulation (PWM) method to implement for the traction inverters of urban rail trains at a very low switching frequency. Unfortunately, its switching patterns are determined by a Fourier analysis of assumed steady-state voltages. As a result, its transient responses are not very good with over-currents and high instantaneous torque pulses. In the proposed solution, the switching patterns of the conventional central 60° modulation are modified according to the dynamic error between the target and actual stator flux. Then, the specific trajectory of the stator flux and current vector can be guaranteed, which leads to better system transients. In addition, stator flux control is introduced to get smooth mode switching between the central 60° modulation and the other PWMs in this paper. A detailed flow chart of the control signal transmission is given. The target flux is obtained by an integral of the target voltage. The actual PMSM flux is estimated by a minimum order flux state observer based on the extended flux model. Based on a two-level inverter model, improved rules in the α-β stationary coordinate system and equations of the switching patterns amendment are proposed. The proposed method is verified by simulation and experimental results.

An Efficient Method of Remote Control for Select Sequence in Process Control (공정제어에서 선택시퀀스를 위한 효율적인 리모트 콘트롤 제어방법)

  • Kong, Heon-Tag;Kim, Chi-Su;You, Jeong-Bong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.1
    • /
    • pp.107-112
    • /
    • 2010
  • When we design the control system used Programmable Logic controller(PLC), if we program a Sequential Function Chart(SFC), It is easy to understand the sequential flow of control, to maintenance the controller and to describe a program. SFC language is programmed by a single sequence, a select sequence and a parallel sequence. In a select sequence, when the select step is error, the whole process is stopped. If the error step has no connection the whole process, the loss is down when we debugging the program without stopping the whole process. Therefore, this thesis shows the efficient method of remote control for select sequence and we confirmed its feasibility through actual example.

Eddy Loss Analysis and Parameter Optimization of the WPT System in Seawater

  • Zhang, Ke-Han;Zhu, Zheng-Biao;Du, Luo-Na;Song, Bao-Wei
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.778-788
    • /
    • 2018
  • Magnetic resonance wireless power transfer (WPT) in the marine environment can be utilized in many applications. However, energy loss in seawater through eddy loss (EL) is another consideration other than WPT in air. Therefore, the effect of system parameters on electric field intensity (EFI) needs to be measured and ELs calculated to optimize such a system. In this paper, the usually complicated analytical expression of EFI is simplified to the product of frequency, current, coil turns, and a coefficient to analyze the eddy current loss (ECL). Moreover, as the calculation of ECL through volume integral is time-consuming, the equivalent eddy loss impedance (EELI) is proposed to help designers determine the optimum parameters quickly. Then, a power distribution model in seawater is conceived based on the introduction of EELI. An optimization flow chart is also proposed according to this power distribution model, from which a prototype system is developed which can deliver 100 W at 90% efficiency with a gap of 30 mm and a frequency of 107.1 kHz.

Study on the Time Improvement of Interrupt Program by SFC (SFC언어에서 인터럽트 프로그램 시간개선에 관한 연구)

  • You, Jeong-Bong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.5134-5139
    • /
    • 2013
  • Ladder Diagram(LD) or Sequential Function Chart(SFC) is used for the design of complex modern control system with Programmable logic controller(PLC). LD is the most widely utilized among PLC standard language. But recently, SFC is used frequently. SFC is very easy to grasp the sequential flow of control logic but is difficult for describing combinational logic. When the interrupt factor is occurred, the main program is stopped. And after the interrupt program is completed, the main program is restart. Therefore the more complex the interrupt program, the main program is interrupted downtime will be that much longer. In this paper, we propose the method for interrupt implementation without the dwell time of the main program by SFC language and confirm his feasibility through the simulation.

Prediction of Aerodynamic Loads for NREL Phase VI Wind Turbine Blade in Yawed Condition

  • Ryu, Ki-Wahn;Kang, Seung-Hee;Seo, Yun-Ho;Lee, Wook-Ryun
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.2
    • /
    • pp.157-166
    • /
    • 2016
  • Aerodynamic loads for a horizontal axis wind turbine of the National Renewable Energy Laboratory (NREL) Phase VI rotor in yawed condition were predicted by using the blade element momentum theorem. The classical blade element momentum theorem was complemented by several aerodynamic corrections and models including the Pitt and Peters' yaw correction, Buhl's wake correction, Prandtl's tip loss model, Du and Selig's three-dimensional (3-D) stall delay model, etc. Changes of the aerodynamic loads according to the azimuth angle acting on the span-wise location of the NREL Phase VI blade were compared with the experimental data with various yaw angles and inflow speeds. The computational flow chart for the classical blade element momentum theorem was adequately modified to accurately calculate the combined functions of additional corrections and models stated above. A successive under-relaxation technique was developed and applied to prevent possible failure during the iteration process. Changes of the angle of attack according to the azimuth angle at the specified radial location of the blade were also obtained. The proposed numerical procedure was verified, and the predicted data of aerodynamic loads for the NREL Phase VI rotor bears an extremely close resemblance to those of the experimental data.

An Effective Implementation Method for Dual Use of Web-based Multidimensional Interactive Digital Contents (웹기반 다차원 민군겸용 인터액티브 디지털 콘텐츠의 효과적인 구현 방안)

  • Gang, Seok-Hun;Kim, Dae-Cheong
    • Journal of National Security and Military Science
    • /
    • s.3
    • /
    • pp.197-242
    • /
    • 2005
  • Active catalog is a kind of digital content that enables consumers to test the functions and features of products from their PCs as if they were using it in real life, by simulating the actions and responses of the product. This new type of interactive digital content can be used extensively to make sales personnel training manuals, sales tools, user manuals and user trouble shooting documents. With active catalogs, companies will be able to compare different designs, show actions according to different functions, and evaluate user reaction to new products without having to produce a single physical prototype or mock-up. At the same time, consumers will be able to understand and 'operate' the product and make well-informed purchase decisions. In this paper, we present a visual event-driven modeling tool, PlayMo, for creating active catalogs, analyze the advantages of using PlayMo, describe the event-driven method used by PlayMo and also introduce two enhanced characteristics of the Event Flow Chart with which the events in PlayMo are structured. Interactive digital content by using the PlayMo3D makes easy, simple and effective design for e-learning, e-catalogue, e-marketing/sales, e-prototyping, customer support, etc. Through its application-ready 3D function visualization solution, engineers and designers can rapidly turn a CAD design model into a 3D interactive virtual product, and the effective function prototyping job can be also completed within a minute.

  • PDF

A Study on the Clinical Use of 7-zone-Diagnostic System (2) - the Comparative Analysis of the Rule and the Decipher for each Equipment - (7구역진단기의 임상응용에 대한 고찰 (2) - 각 제품에 따른 원리와 판독의 비교 -)

  • Song, Beom-Yong
    • Journal of Acupuncture Research
    • /
    • v.23 no.5
    • /
    • pp.11-21
    • /
    • 2006
  • The 7-zone-diagnostic system(ABR-2000, BIO MEDIC 700Plus, CP-6000A, OMD 3000, VEGA-DFM 722) is a diagnostic device which applies pulse signals to predetermined bodily locations. Applying alternating positive and negative stress to tissues with positive and negative pulses first manifests itself as negative and positive wave forms. This system make a diagnosis of functional disorder or some typical organic diseases include stress of the mind or the body, and the energetic situation, reserves. We are known a disorder or disease throw the result charts. And these result represents various characteristic signals are assisted diagnosis and care. These result chart contains disorder flow wave forms and some valuable diagnostic hints or marks. But we have several various products for the 7-zone-diagnostic system. I think that we need the comparative analysis of the general rule and the decipher for each equipment. Because these letters(marks) each product are different, we necessary various plentiful research and suitable statistics in these points. And we must carry out many various research in the future.

  • PDF

A Study on the VHDL Code Generation Algorithm by the Asynchronous Sequential Waveform Flow Chart Conversion (비동기 순차회로 파형의 흐름도 변환에 의한 VHDL 코드 생성 알고리즘에 관한 연구)

  • 우경환;이용희;임태영;이천희
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2001.05a
    • /
    • pp.82-87
    • /
    • 2001
  • In this paper we described the generation method of interface logic which can be replace between IP and IP handshaking signal with asynchronous logic circuit. Especially, we suggest the new \"Waveform Conversion Algorithm : Wave2VHDL\", if only mixed asynchronous timing waveform suggested which level type input and pulse type input for handshaking, we can convert waveform to flowchart and then replaced with VHDL code according to converted flowchart. Also, we assure that asynchronous electronic circuits for IP interface are generated by applying extracted VHDL source code from suggested algorithm to conventional domestic/abroad CAD Tool, and then we proved that coincidence simulation result and suggested timing diagram.g diagram.

  • PDF