• Title/Summary/Keyword: Floors

Search Result 874, Processing Time 0.025 seconds

The Validation of Newly Developed Portable Slipmeter (새롭게 개발된 휴대용 미끄럼 저항 측정기의 성능검증)

  • Kim, Jung-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.1
    • /
    • pp.18-23
    • /
    • 2013
  • The purpose of this study were to develop and validate a prototype slipmeter used on-site floor. The developed slipmeter was dreg sled type. It measured static coefficient of friction(SCOF). The developed slipmeter was evaluated with ASTM 2508-11 which use four different standard surfaces(polished granite, glazed porcelain, vinyl composite tile, and ceramic tile). The SCOF was then measured with developed slipmeter under the three different contaminants and seven different floors. The test results of slipmeter were also compared with those of BOT-3000, floor surface roughness, and human perception. The test results revealed that developed slipmeter successfully ranked all four standard surfaces and differentiated among standard surfaces with varying degrees of slipperiness. The developed slipmeter couldn't properly measure slipperiness under the two kind of floors(polished tile, ground steel plate) and one kind of contaminant(glycerol). The test results of developed slipmeter had stronger correlation with those of BOT-3000 and floor roughness under the water and detergent solution than under the glycerol. The test results of developed slipmeter also showed stronger correlation with those of BOT-3000 and surface roughness than those of human perception. The newly developed slipmeter had been found to give consistent results under the test conditions except for two kind of floors(polished tile, ground steel plate) and one kind of contaminant(glycerol).

A system of multiple controllers for attenuating the dynamic response of multimode floor structures to human walking

  • Battista, Ronaldo C.;Varela, Wendell D.
    • Smart Structures and Systems
    • /
    • v.23 no.5
    • /
    • pp.467-478
    • /
    • 2019
  • Composite floor structures formed by continuous slab panels may be susceptible to excessive vibrations, even when properly designed in terms of ultimate limit state criteria. This is due to the inherent vibration characteristics of continuous floor slabs composed by precast orthotropic reinforced concrete panels supported by steel beams. These floor structures display close spaced multimode vibration frequencies and this dynamic characteristic results in a non-trivial vibration problem. Structural stiffening and/or insertion of struts between floors are the usual tentative solution applied to existing vibrating floor structures. Such structural alterations are in general expensive and unsuitable. In this paper, this vibration problem is analyzed on the basis of results obtained from experimental measurements in typical composite floors and their theoretical counterpart obtained with computational modeling simulations. A passive control system composed by multiple synchronized dynamic attenuators (MSDA) was designed and installed in these floor structures and its efficiency was evaluated both experimentally and through numerical simulations. The results obtained from experimental tests of the continuous slab panels under human walking dynamic action proved the effectiveness of this control system in reducing vibrations amplitudes.

A Comparative Study on Suicide Rates of Upper and Lower Floors of High-rise Apartment (고층아파트의 저층과 고층의 자살률 비교 연구)

  • Kim, Young-Ook;Ji, Bong-Geun;Kim, Joo-Young
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.8
    • /
    • pp.57-64
    • /
    • 2019
  • This study attempts to analyse the effects of high-rise living on suicide rates. All the apartments in the City A and every suicide were examined in detail. Research methods are as follows. First, a database including tenure type and number of residents in all apartment complexes was created. Second, apartments were categorized into two income groups of private apartments and social housing, and spatial configuration characteristics of a typical apartment were analysed. Third, differences in suicide rates were analysed for lower and upper levels in both apartment categories. Finally, the relationship between high and lower levels of apartments with their spatial configuration characteristics and suicide rates was compared. The analysis shows significant differences between lower and upper floors living residents' suicide rates. It can be stated that the low-income residents are more sensitive to living in high-rise environment. Also, it suggests the need to improve the high-rise living environment of vulnerable social groups. In addition, spatial integration decrease in upper floors of high-rise buildings, and it can be interpreted that spatial configuration may affect residents' pathological disorders or even suicidal behaviors.

A Study on Evaluation Method of Floor Noise Reduction and Blocking Performance for Apartment Buildings in Korea (국내 공동주택 건축물 층간소음 저감 방안 및 차단 성능 등급평가법에 관한 고찰)

  • Jung, Kyung-Tae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.24 no.3
    • /
    • pp.69-77
    • /
    • 2024
  • The purpose of this study is to present a plan for reducing noise between floors of apartment houses in Korea and to examine the method for evaluating noise blocking performance rating between floors. The definition of floor noise and classification method of floor noise can be described, and floor noise can be distinguished into lightweight impact sound and heavy impact sound. The wall-type structure, which is mainly adopted in domestic apartments, relatively transmits vibration caused by impact sources rather than using columns and beams, so noise problems between floors are relatively higher than systems using columns and beams. Three representative methods for reducing and blocking floor noise are described, and criteria for evaluating the effectiveness of floor noise reduction by each method are described. In addition, the method for noise reduction and blocking grades for each construction method currently applied in Korea was described, and as a result, it was judged that the domestic rating evaluation method was not suitable for the current domestic situation, and a new evaluation method and standard were needed.

The Characteristics of Traffic Noise and Its Effects on Inhabitants' Life at an Apartment Area in Taejon City (대전 신도시 일부 아파트지역 교통소음의 특성과 주민생활에 미치는 영향)

  • Park, Chan-Ho;Chang, Seong-Sil
    • Journal of Environmental Health Sciences
    • /
    • v.25 no.3
    • /
    • pp.94-102
    • /
    • 1999
  • To estimate the effects of environmental noise on inhabitants' life in an apartment area at Taejon, noise levels and traffic volume of major roads were measured. 203 housewives were surveyed by questionaires including general factors, noise related factors and three items of life effects: subjective evaluations on the general environment, annoyance, and life disturbance due to environmental noise. At the boundary adjacent to the road with more traffic volume, noise level was higher; according to the time, the amount of noise level was in the morning, in the evening, at noon, and at night in order. Most of boundary noise levels were higher than those of recommended standard environmental noise levels in a residential area. The boundary noise level showed a very significant linear relationship with traffic volume of near roads. Noise level difference in the apartments adjacent to three roads was ranged 2.4~6.7dB between in windows open and close state. The apartments adjacent to 9 lane or 6 lane-road, which were protected by noise prevention wall and 20m or more distance from the roads, showed higher noise level at middle floors and high floors than those of low floors; but the buildings adjacent to 4 lane-road, with no protection, showed higher noise level at low and middle floors than those of high floors. Among 203 housewives, 120(59.1%) participated in this study, and 86(73.2%) of them answered that the most serious environmental noise was traffic noise from near roads. Comparing traffic noise levels with those of before-migration, 67.0% participants found the environmental noise became louder. Fifty eight(49.5%) of the participants wanted noise protection wall and 15(25.9%) of them were willing to charge the fee. Less perception on the present noise comparing to those before-migration, less traffic volume, and lower noise levels in the apartments were related to higher scores of self-evaluation on the environment. Higher susceptibility on the present noise, areas with more traffic volume, higher boundary noise levels, and higher noise levels showed higher scores of annoyance on environmental noise and life disturbance. Considering above all things, it was suggested that traffic noise in this area was the major problem of environmental noise, and its' effect was so serious that inhabitants needed some preventive measures for better life quality.

  • PDF

The Proposition of Domestic Sprinklers Installation Standard and the Fire Services Act (국내 스프링클러 설치기준과 소방관련 법에 관한 고찰)

  • Kim, Yong-Moon;Lee, Young-Jai
    • Journal of Korean Society of Disaster and Security
    • /
    • v.7 no.2
    • /
    • pp.17-24
    • /
    • 2014
  • Recently, many accidents occur frequently because sprinklers aren't installed or don't work right when there are outbreak of fire in houses and aggregate buildings. Therefore, they can result in damage for humans and loss of property. Sprinklers are the most appropriate which can extinguish buildings' fire in the initial stages. Through lack of legal system, in domestic cases, sprinklers cannot operate their inherent performance. Domestic standard simply classifies installation objects according to types of business and forms of buildings, also divides into uses and floors of buildings. Especially it only regulates that sprinklers must be installed every floors in particular fire buildings that have more than eleven floors. While it doesn't need to install sprinklers below ten floors, so we are threatened the safety. In this study, we derived causes and implications by analyzing concepts of sprinklers facilities, installation standards in domestic and foreign legal system, and recent cases that expanded damages in fire accidents because of weak point of installation and control standards. In domestic cases, as a result, government has to provide an institutional strategy and law that regulate duty to install sprinklers to all aggregate buildings regardless of floors in terms of new buildings. Also, if someone who has existing buildings wanted to install them, government would guarantee subsidy to encourage installation. In addition, government supervises fire-fighting activities when there are fire by compensating standards about regular inspection by a qualified technician, operation and maintenance of sprinklers as well as reinforcement of administrative criteria.

A Study of the Planning Characteristics of Neowa Houses Applicable in Contemporary Housing Plans (너와집 평면특성의 현대적 차용에 관한 연구)

  • Yun, Jieheerah
    • Journal of the Korean housing association
    • /
    • v.26 no.2
    • /
    • pp.81-88
    • /
    • 2015
  • The purpose of this study was to investigate the possibility of applying the planning characteristics of Neowa houses to contemporary residential structures. Contrary to the popular assumption that traditional Korean houses have decentralized plans, local building traditions observed in Neowa houses show that the diversity among hanoks allows the incorporation of traditional spatial organization into the contemporary residences. By analyzing the spatial organization of Neowa houses, three advantageous planning characteristics were found. First, the presence of indoor wooden floors (maru or daechung) as well as outdoor wooden floors in Neowa houses is practical for Korea's weather marked by humid summers and icy winters. Secondly, the internal orientation of space in Neowa houses is more appropriate in the contemporary context of a highly urbanized society emphasizing family privacy. Thirdly, the flexibility and interchangeability of interior elements can be applied to improve efficiency. By applying the aforementioned characteristics, this study suggests ways to adopt traditional features to improve contemporary residences.

A Study on the Basement Residential Planning of Consider the Outdoor Environment (실외 환경을 고려한 지하층 주거 계획에 관한 연구)

  • Kwon Hwang-Soo;Lee Min-Sup
    • Journal of the Korean housing association
    • /
    • v.16 no.4
    • /
    • pp.1-7
    • /
    • 2005
  • In this study aim at searching for the basement residential planning of considering outdoor spaces. It look after research results, there should be necessary for the inflow of outdoor environment factors. This basement planning is core's area expending, or installing expended dry areas and acquiring side open spaces, installing arcades, installing atrium or court yard, utilizing maisonette spaces, activating pilotis on ground floors, openning main hall, earth sheltering method, etc. These should be improvement for easy step to change basement floors easily through underground floor extend, major repair, use change of present buildings and needs to the idea through architectural design competition.

A Study on the Improvement Floor Impact Sound Insulation by Ceiling Structure in Apartment Houses (천장구조를 이용한 공동주택 바닥충격음 차단성능 개선에 관한 연구)

  • Ki, No-Gab;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1038-1042
    • /
    • 2007
  • The factors influencing the floor impact sound insulation include floor finishing materials, shock absorbing floors (slabs included), and ceiling structures. The ceilings of the apartment houses, currently built in Korea, are set up with lower parts of slabs and paper finishing, or with double floors for protecting against floor impact sounds in order to improve the sound insulating performance. The most common the method of ceiling structure construction consists of 'wood boarded frames + Gypsum boards + ceiling papers', which is called the wood boarded frame method. This study aimed to measures and evaluates floor impact sound insulation by which the ceiling space are widened according to suppression system is added in apartment house ceiling structure.

  • PDF