• Title/Summary/Keyword: Floor system

Search Result 1,837, Processing Time 0.027 seconds

A Development of a Dynamic Load Function for a composite Deek Floor System (합성데크를 사용한 바닥판의 동적하중 이론식 개발)

  • 김태윤
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.04a
    • /
    • pp.127-134
    • /
    • 1999
  • Vibration problem occurring at the metal deck floor system not only reduces the serviceability of a building but also reduces the usability of a floor system. Most problem occurring at the metal deck floor results from the human movement such as walking and running. However the vibration induced by running does not occur continuously except the special case. therefore the floor vibration due to walking was only considered on this paper,. Vibration occurring due to human walking was measured and the corresponding load function was derived through the Fast Fourier Transform(FFT)

  • PDF

Effect of Supply and Return Locations of a Floor-Supply Cooling System on Thermal Comfort

  • Kim, Young-Il;Kim, Jo-Seph;Yoo, Ho-Seon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.4
    • /
    • pp.37-46
    • /
    • 2001
  • This study numerically investigates thermal comfort of a space cooled by a floor-supply air-conditioning system, in which three different combinations of supply and return locations, one floor-supply/ceiling-return and two floor-supply/floor-return, are treated. A complementary experiment is performed to validate the present numerical analysis, and the prediction agrees favorably with the measured data. In the numerical procedure, a simplified model mimicking the inlet flow through a diffuser is developed for efficient simulations. The calculated results show that the ceiling-return type is far better in terms of thermal comfort than the floor-return ones within the extent of this study, which seems to be caused by effective vertical penetration of the supply air against natural convection. It is also revealed that the arrangement of port locations in the floor-supply/floor-return system has insignificant effect on the cooling performance. For selecting a proper system, other characteristics including the heating performance should be accounted for simultaneously with the present considerations.

  • PDF

Performance Evaluation of the Floor Impact Sound Insulation in Steel Framed Modular House (강재프레임 모듈러주택의 바닥충격음 성능평가)

  • Chun, Young-Soo;Bang, Jong-Dae;Kim, Gap-Deug;Yoo, Song-Lee
    • Land and Housing Review
    • /
    • v.5 no.2
    • /
    • pp.81-89
    • /
    • 2014
  • This paper presents various attempts to secure the floor impact sound insulation performance on the dry floor system of steel framed modular house that lately attracted domestic attention. Test results show that in the condition of using dry floor system of D31(D32), the light-weight impact noise performance records the top level in the floor impact sound insulation performance grading system. the heavy-weight floor impact noise performance meets the minimum sound level limit in the floor impact sound insulation performance grading system that enacted regulation on housing construction standards.

The Development of a Shop Floor-Centered Information System for the Integration of Design and Manufacturing Data (생산 현장 중심의 설계/생산 통합 정보 시스템 개발)

  • Han K. H.;Park C. W.;Oak J. S.;Kim K. S.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.10 no.4
    • /
    • pp.237-243
    • /
    • 2005
  • To increase the productivity and efficiency of an enterprise, all relevant product information should be provided to shop floor workers timely and in a unified form because shop floor workers are final consumers of most accumulated information generated from various departments of an enterprise. But, most existing enterprise information systems have an emphasis upon providing design/manufacturing information to office workers. Proposed in this study is the development of integrated design/manufacturing information system focused on providing cohesive information required to shop floor activities. For developing integrated information system, the functional requirements at the shop floor are identified and analyzed. Based on the extracted functional requirements, object-oriented system design and implementation is conducted. By using this system, shop floor workers can use all relevant information required to their daily operation in a integrated and unified form.

A simplified method for determining the acceleration amplitudes of long-span floor system under walking/running loads

  • Cao, Liang;Chen, Y. Frank
    • Structural Engineering and Mechanics
    • /
    • v.75 no.3
    • /
    • pp.377-387
    • /
    • 2020
  • Modern long-span floor system typically possesses low damping and low natural frequency, presenting a potential vibration sensitivity problem induced by human activities. Field test and numerical analysis methods are available to study this kind of problems, but would be inconvenient for design engineers. This paper proposes a simplified method to determine the acceleration amplitudes of long-span floor system subjected to walking or running load, which can be carried out manually. To theoretically analyze the acceleration response, the floor system is simplified as an anisotropic rectangular plate and the mode decomposition method is used. To facilitate the calculation of acceleration amplitude aP, a coefficient αwmn or αRmn is introduced, with the former depending on the geometry and support condition of floor system and the latter on the contact duration tR and natural frequency. The proposed simplified method is easy for practical use and gives safe structural designs.

A study on the establishment of vibration conditions of a composite deck floor with panel heating systems for a steel structure (Panel heating을 적용한 철골조 건물의 합성테크 진동조건 설정에 관한 연구)

  • Park, Jin-Young;Kim, Hee-Cheul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.972-977
    • /
    • 2000
  • One of the major differences of Korean residential building compared with other countries is a rigid diaphragm of a floor due to the panel heating system. An increment of a gravity floor load might cause vibration problem when the composite floor system is introduced to the panel heating system. Since the noise criteria of a residential building is lower than that of an office building, the development of a noise absorbing system should be preceded. The response evaluation was performed for the finished floor, that is with panel heating and noise absorbing system. The natural frequency was obtained both from an experimental study and an analytical study. An appropriate vibration condition of a floor with panel heating and noise absorbing systems was evaluated from this study.

  • PDF

The comparison of thermal characteristics of new Han-ok floor heating for applying modern On-dol system (현대 온돌 시스템 적용을 위한 신한옥 바닥난방의 열적특성 비교)

  • Lee, Tai-Gang;Lee, Ju-Yeob;Song, Min-Jeong;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.61-69
    • /
    • 2013
  • The experiment on thermal characteristics of on-dol systems were carried out to apply to New Han-ok's heating system. Change of surface temperature varied with heating times, distribution of surface temperature, radiation property were surveid on four on-dol system in laboratory conditions. Followings are results. 1) "Hwang-to unit" was most favorable condition of the distribution of floor surface temperature. And the results from reaching time to thermal comfort temperature of on-dol system showed that "Hwang-to unit" was the most favorable to continuance of floor temperature. 2) There were a little difference in surface floor radiations of $30^{\circ}C$ for three wet on dol-systems. 3) It was suggested that "Hwang-to unit" is the most appropriate to floor heating system of new han-ok considering eco-friendship and continuance of floor temperature in intermittent heating condition.

Connection stiffness and natural frequency of DuraGal lightweight floor systems

  • Zhao, X.L.;Taplin, G.;Alikhail, M.
    • Structural Engineering and Mechanics
    • /
    • v.15 no.3
    • /
    • pp.269-284
    • /
    • 2003
  • This paper reports a series of component tests on a lightweight floor system and a method to predict the natural frequency of the floor using a frame analysis program. Full-scale floor tests are also briefly described. DuraGal steel Rectangular Hollow Sections (in-line galvanised RHS) are used as joists, bearers and piers in DuraGal lightweight floor systems. A structural grade particleboard is used as decking. Connection stiffness between different components (bearer, joist, pier and floor decking) was determined. A 40% composite action was achieved between the RHS joist and the particleboard. Both 2D and 3D models were developed to study the effect of connection stiffness on predicting the natural frequency of DuraGal lightweight floor systems. It has been found that the degree of shear connection between the bearer and the joist has a significant influence on the floor natural frequency. The predicted natural frequencies are compared with measured values from full scale floor testing.

A Study on Comparison of Capacity between Wet.Dry Floor Heating Systems Using Geothermal Heat Pump (지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구)

  • Lee, Byoung-Doo;Lee, Se-Jin;Lee, Dae-Woo;Oh, Sung-Hae;Nam, Woo-Dong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.567-570
    • /
    • 2009
  • The present study conducted comparative evaluation of wet dry floor heating systems using geothermal heat pump. Circulation hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler was used. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.89^{\circ}C$ for wet type and $32.66^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. In the results, for floor heating system using low temperature circulation water, wet type was not enough to meet stable and comfortable radiant floor heating due to low floor temperature and access time to indoor set temperature. While dry type was practicable for stable floor heating due to fast rise of indoor set temperature and comfortable floor temperature.

  • PDF

Floating Floor of Multi-Supporting System (복합지지구조를 가진 뜬바닥 시스템)

  • 박영환;정환돈;오호진
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.928-931
    • /
    • 2003
  • In this research, we suggest the effective technique that the thickness of slab isn't increased, and considering proper shock absorbing material and supporting point, we make the floating floor which has multi-supporting system floating nut. As the result, it is effective in reduction of heavy weight system as well as one of light weight

  • PDF