• 제목/요약/키워드: Floor level

검색결과 816건 처리시간 0.023초

신속제조환경에서의 새로운 생산입력통제방식에 관한 연구 (A Study of New Production Input Control in an Agile Manufacturing Environment)

  • 김현수
    • 대한산업공학회지
    • /
    • 제23권4호
    • /
    • pp.699-708
    • /
    • 1997
  • Production control is usually composed of due-dote assignment, production input control, and priority dispatching rule. A production input control(PIC) is mainly to control the WIP level on the shop floor. On the other hand, a priority dispatching rule(PDR) is mainly to control the tardiness/earliness of on order and number of tardy jobs. Therefore, if we select a particular PIC which can control only a particular performance measure(i.e., tardiness), it may cause worsening other performance measure(i.e., WIP level, shopfloor time, etc.) This newly developed production input control, DRD(Dual Release-Dates), is mainly designed to control the WIP level on the shop floor by employing two different release-dates of an order(earliest release. date and latest release-date and the release condition (relationship between the current WIP level and the pre-defined maximum WIP level) while trying to meet the due-date of the order.

  • PDF

마감모르타르 물결합재비에 따른 바닥충격음 특성 변화 (Characteristics of the floor impact sound by water to binder ratio of mortar)

  • 이원학;한찬훈
    • 한국음향학회지
    • /
    • 제40권6호
    • /
    • pp.671-677
    • /
    • 2021
  • 본 연구의 목적은 마감모르타르의 물결합재비가 공동주택 바닥충격음에 미치는 영향을 조사하는 것이다. 이를 위하여 동일한 동탄성계수를 지닌 Expanded Polystyrene(EPS) 완충재와 52 %, 66 %, 72 % 의 물결합재비를 가진 모르타르를 활용하여 뜬바닥구조를 시공하였으며, 표준실험동에서 바닥충격음을 측정하였다. 실험결과, 경량충격음에 있어서는 물결합재비 52 % 일 때, 밀도가 높은 관계로 경량충격음 전달특성이 높게 나타났다. 마감모르타르의 물결합재비가 높아지면 완충재 상부층 질량이 낮아지고, 이로 인해 뜬바닥구조의 고유진동수가 63 Hz 대역으로 이동하게 되면서 중량충격음의 음압레벨이 높게 나타났다. 이를 통하여 마감모르타르의 물결합재비가 중량충격음에 미치는 특성을 규명하였다.

지체장애인의 관점에서 본 소규모 아파트 공간에서의 유니버설 디자인 특성 (Universal Design Characteristics in Small Apartment Housing Focusing on the Physically Disabled)

  • 오찬옥
    • 한국주거학회논문집
    • /
    • 제11권3호
    • /
    • pp.99-107
    • /
    • 2000
  • The purpose of this study was to identify the universal design characteristics in residential environments. The subjects were 135 physically disabled persons who lived in the rental multi-family housing apartments in Pusan. Interview method was used for this study. They were an average age of 51 years and 63% were male. They were low income families and lived in 12 pyung ($39.75\textrm{m}^2$) apartments. They were asked about what housing characteristics were constraints in their daily living. They pointed out that the constraints in their apartments were as follows: 1) the small amount of space in the bathroom, kitchen, bedroom, and the entrance area of housing unit, 2) the unflat floor level between the bathroom and the hallway, or the balcony and the bedroom, 3) the slippery floor finish in the bathroom, 4) lack of grab bars or handrails in the bathroom and the ramp, 5) the kitchen work centers and the electric switches at improper height, and 6) the steep ramp. Therefore, the universal design characteristics in residential environments were the adequate amount of space, flat floor level, non-slippery floor finish, grab bars or handrails, accessible height, and ramp.

  • PDF

학교주변 도로교통 소음 및 그에 따른 학생 청감반응과의 상관관계 연구 (A Study on the correlation between the traffic noise around the school buildings and the students' response to it)

  • 김종수;최동훈;안철우;이철승;문추연;김장호
    • 환경위생공학
    • /
    • 제17권2호
    • /
    • pp.55-62
    • /
    • 2002
  • For my thesis I have analyzed the differences between the traffic noise level surrounding the schools and the perceived level of noise. 1 have used the ways of measurement and questionnaires to support my study. According to the analysis, the measured noise level was higher than the expected noise level. The equivalent noise level was proven to be higher when the windows of the classrooms were open. The noise level was also higher on the third floor than the first floor. The correlation between the measured noise level and the perceived level of noise was tested in each school. The school which had a higher expected noise level showed a high perceived level of noise. The measured noise level and the perceived level of noise became larger on the higher floors. Through the questionnaires, the traffic noises were proven to be the largest noise-making source surrounding the schools. Most of the students replied on the questionnaires that they have been consistently bothered by the noise. It interfered with their studies and concentration. Also, the sound of their voices became louder because of the noise around their schools. Therefore, I have come to the conclusion that the traffic noises that surround the schools give the students negative influences.

바닥 진동 거동 및 충격원 특성을 고려한 바닥 중량 충격음 평가방법 고찰 (Consideration on Rating Method for Heavy Impact Sound Taking Account of the Characteristics of Floor Vibration and Impact Sources)

  • 이민정;최현기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권4호
    • /
    • pp.69-79
    • /
    • 2017
  • 표준 중량 충격원의 실제 충격원 재현성에 대한 논란이 있음에도 현재 기준에서는 뱅머신 방식만 사용하고 있다. 현행 기준의 평가방법 및 등급 기준이 충격원 특성을 고려하지 못하고 있어 충격원의 선택에 따라 바닥충격음 차단 성능 등급에 차이가 발생하기 때문이다. 본 연구는 충격원 특성 외에 바닥 진동 거동 특성을 함께 고려한 현행 기준의 바닥충격음 평가 방법 고찰을 목적으로 한다. 공동주택 mock-up 실험동에서 표준 중량 충격원과 실충격원에 대하여 바닥충격음을 측정하고 이를 이용하여 해외 평가 방법과 우리나라의 평가 방법을 비교 검토하였다. 또한 현행 바닥충격음 평가 기준의 대상 주파수 범위를 벗어나는 저주파수 대역의 음압레벨은 네텔란드의 저주파 소음 인지 곡선과 국내 연구자가 제안한 저주파 소음 기준안을 이용하여 평가하였다. 그 결과 기준 및 평가 산정 방법에 따라 성능 평가 결과가 상이하며, 바닥 진동의 지배 주파수 범위에서 모든 충격원에 대한 바닥충격음 가청 소음으로 인식하여 성가시게 느낄 가능성이 매우 크다. 현행 평가 기준의 단일수치 평가량 산정 방법은 충격원에 따라 상이한 음압레벨 스펙트럼 특성을 제대로 반영하지 못하며, 바닥의 진동 거동 지배 주파수를 포함하는 저주파수 대역의 음압레벨을 고려하지 않고 있어 바닥충격음에 대한 평가 결과와 사람의 인지 수준에 차이가 발생할 수 있다. 따라서 충격원에 따른 음압레벨의 스펙트럼 특성과 저주파수 대역의 음압레벨을 반영할 수 있도록 현행 기준의 평가 방법을 보완할 필요가 있다.

산업단지 내 저층과 고층 아파트의 외기 중 호흡성분진과 일산화탄소 수준 (Ambient Levels of CO and PM10 at Low- and High-floor Apartments in Industrial Complexes)

  • 조완근;이준엽
    • 한국환경과학회지
    • /
    • 제15권8호
    • /
    • pp.719-725
    • /
    • 2006
  • Since low-floor apartments ate vertically closer to patting lots and roadways, it is hypothesized that residents in low-floor apartments may be exposed to elevated ambient levels of motet vehicle emissions compared to residents in high-floor apartments. The present study examined this hypothesis by measuring two motor vehicle source-related pollutants(CO and PM10) in ambient air of high-rise apartment buildings within the boundary of industrial complexes according to atmospheric stability The ambient air concentrations of CO and PM10 were higher for low-floor apartments than for high-floor apartments, regardless of atmospheric stability, The median concentration ratio of the low-floor air to high-floor alt ranged from 1.3 to 2.0, depending upon atmospheric stabilities, seasons and compounds. Moreover, the CO and PM10 concentrations were significantly higher in the winter and in the summer, regardless of the Hoot height. Atmospheric stability also was suggested to be important for the residents' exposure of high-rise apartment buildings to both CO and PM10. The median ratios of surface inversion air to non-surface inversion air ranged from 1.2 to 1.7 and from 1.0 to 1.6 lot PM10 and CO, respectively, depending upon seasons. Conclusively, these parameters(apartment floor height, season, and atmospheric stability) should be considered when evaluating the exposure of residents, living in high-rise apartment buildings, to CO and PM10. Meanwhile, the median PMl0 outdoor concentrations were close to or higher than the Korean annual standards for PM10, and the maximum PM10 concentrations substantially exceeded the Korean PM10 standard, thus suggesting the need for a management strategy for ambient PM 10. Neither the median nor the maximum outdoor CO concentrations, however, were higher than the Korean CO standard.

Effect of Floor Space Allowance on Pig Productivity across Stages of Growth: A Field-scale Analysis

  • Lee, Joon H.;Choi, Hong L.;Heo, Yong J.;Chung, Yoon P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제29권5호
    • /
    • pp.739-746
    • /
    • 2016
  • A total of 152 pig farms were randomly selected from the five provinces in South Korea. During the experiment, the average temperature and relative humidity was $24.7^{\circ}C$ and 74% in summer and $2.4^{\circ}C$ and 53% in winter, respectively. The correlation between floor space allowance (FSA) and productivity index was analyzed, including non-productive sow days (NPD), number of weaners (NOW), survival rate (SR), appearance rate of A-grade pork (ARA), and days at a slaughter weight of 110 kg (d-SW) at different growth stages. The objectives of the present study were i) to determine the effect of FSA on the pig productivity index and ii) to suggest the minimum FSA for pigs based on scientific baseline data. For the pregnant sow, NPD could be decreased if pregnant sows were raised with a medium level (M) of FSA (3.10 to $3.67m^2/head$) while also keeping the pig house clean which improves hygiene, and operating the ventilation system properly. For the farrowing sows, the NOW tended to decrease as the FSA increased. Similarly, a high level of FSA (H) is significantly negative with weaner SR of farrowing sows (p-value = 0.017), indicating this FSA tends to depress SR. Therefore, a FSA of 2.30 to $6.40m^2/head$ (very low) could be appropriate for weaners because a limited space can provide a sense of security and protection from external interruptions. The opposite trend was observed that an increase in floor space (> $1.12m^2/head$ leads to increase the SR of growing pigs. For the fattening pigs, H level of FSA was negatively correlated with SR, but M level of FSA was positively correlated with SR, indicating that SR tended to increase with the FSA of 1.10 to $1.27m^2/head$. In contrast, ARA of male fattening pigs showed opposite results. H level of FSA (1.27 to $1.47m^2/head$) was suggested to increase productivity because ARA was most affected by H level of space allowance with positive correlation ($R^2=0.523$). The relationship between the FSA and d-SW of fattening pigs was hard to identify because of the low $R^2$ value. However, the farms that provided a relatively large floor space (1.27 to $1.54m^2/head$) during the winter period showed d-SW was significantly and negatively affected by FSA.

공동주택에서 중공 슬래브 바닥의 차음 특성에 관한 연구 (A Study on the Characteristics of Sound Insulation at the Circular Voided Concrete Floor in the Multi-Housing)

  • 손철수
    • 한국주거학회논문집
    • /
    • 제11권1호
    • /
    • pp.171-181
    • /
    • 2000
  • The purpose of the resent research is to investigate the characteristics of sound insulation at the circular voided concrete slab in the multi-housing. In order to do this research, the method for field measurement of floor impact sound level was used following the Korea Standard F2810-1996. For the multi-housing, three kinds of circular voided concrete slabs are used to measure the characteristics of sound insulation.The results are as follows; 1.The main factor affecting the characteristics of sound insulation at the circular voided concrete slab in the multi-housing is sound-absorbing materials in the circular tube. 2. The main factor to effect the difference of sound pressure level is circular tube in the concrete slab. 3. The forms of circular tubes effect the characteristics of sound insulation at the circular tube. 4. Sound Pressure Level resulting from the piping direction of circular tubes in little different to octave band level.More study will be needed about the depth and distance of sound insulation materials, and the components of sound insulation materials for the multi-housing.

  • PDF

폐기물 소각시설 내부 소음에 관한 연구 (A Study on Noise in Waste Facilities)

  • 서병석;박노국;전용한
    • 대한안전경영과학회지
    • /
    • 제22권2호
    • /
    • pp.15-21
    • /
    • 2020
  • Industrial facilities need design to predict and reduce noise from design to prevent and reduce noise. The purpose of this study is to predict worker's environment and evaluate safety by analyzing noise inside underground blower room and air compressor room with fluid machinery in waste facility. This waste incineration facility was analyzed based on the ground floor, ground floor blower chamber, and air compressor chamber. The results of SPL(Sound Pressure Level) analysis at 1.5m away, which are frequently used to measure the SPL as a noise source, are as follows. SPL of basement level: 46.80[dB], SPL of ground layer: 48.57[dB]. As a result, it was expected that the noise level would be considerably lower than the 8 hours 50[dB] noise exposure per day.

역타공법 중심의 골조 공기단축을 위한 시공시퀀스 변경에 따른 구조해석 및 요소기술 분석 (Structure and Construction Technology Analysis about Construction Sequence Change for Superstructure Construction Period Reduction in Top-down Method)

  • 박용현;주영규
    • 대한건축학회논문집:구조계
    • /
    • 제35권6호
    • /
    • pp.101-109
    • /
    • 2019
  • The purpose of this study is to improve a general Top-Down construction process for superstructure construction period reduction. In a general Top-Down construction sequence, the ground floor slab is set up first. Subsequently, 1st basement level construction including core walls is constructed. Initiation of the ground level superstructure gets waited until then. In this study, removable deck plate installation on the bottom of the core walls of ground level is preceding the concrete casting, therefore, ground level superstructure construction is able to get started earlier. Up to first typical floor concrete casting, total of seventy-two working(calendar) days will be resulted in a reduction from the total construction periods.