• 제목/요약/키워드: Floor impact sound pressure level

검색결과 43건 처리시간 0.031초

공동주택의 바닥 충격 진동 해석을 위한 유한요소법 응용 (Application of Finite Element Method to Floor Impact Vibration Analysis in the Apartment Buildings)

  • 서상호;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.387-390
    • /
    • 2005
  • Finite element method was applied to the vibration analysis of concrete slab system in apartment building. To save the time and cost the 2 dimensional finite element model was proposed. At first, experimental results show that sound peak components to influence the overall level and the rating of floor impact sound insulation were coincident with natural frequencies of the reinforced concrete slab. Second, there is linear relationship between the impact sound pressure level and vibration acceleration level. Third, 2 dimensional finite element model was enough to analyze the vibration analysis of floor structure system.

  • PDF

T사 바닥충격음 실험동 소개 (Introduction of Floor Impact Sound Insulation Performance Test Lab. of T Company)

  • 백건종;신훈;송민정;장길수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.17-20
    • /
    • 2008
  • To develop floor impact sound resilient materials of apartment house effectively, floor impact sound insulation performance test lab. was designed and constructed in T company. Introducing specification and basic performance of this lab. could be helpful in plan and design of another lab. Floor space size of this lab. is $4.2m{\times}5.5m$ and this size is similar with that of living room of usual apartment house's (about $100m^2$) and the height of lab. is 2.4m. Slab thickness is designed by 180mm. Frequency characteristics is similar to general apartment house. Reverberation time of sound receiving room displays 1.26sec in 125Hz by establishing sound-absorbing materials. For light weight impact sound insulation performance of concrete bare floor structure is estimated by $L_{i,AW}\;=\;73$ and for heavy weight is estimated by $L_{i,Fmax,AW}\;=\;50$. Sound pressure level distribution of sound receiving room is ranged very uniformly. With these results, floor impact sound resilient materials could be evaluated and the results could be trusted by comparison tests.

  • PDF

바닥 진동 거동 및 충격원 특성을 고려한 바닥 중량 충격음 평가방법 고찰 (Consideration on Rating Method for Heavy Impact Sound Taking Account of the Characteristics of Floor Vibration and Impact Sources)

  • 이민정;최현기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권4호
    • /
    • pp.69-79
    • /
    • 2017
  • 표준 중량 충격원의 실제 충격원 재현성에 대한 논란이 있음에도 현재 기준에서는 뱅머신 방식만 사용하고 있다. 현행 기준의 평가방법 및 등급 기준이 충격원 특성을 고려하지 못하고 있어 충격원의 선택에 따라 바닥충격음 차단 성능 등급에 차이가 발생하기 때문이다. 본 연구는 충격원 특성 외에 바닥 진동 거동 특성을 함께 고려한 현행 기준의 바닥충격음 평가 방법 고찰을 목적으로 한다. 공동주택 mock-up 실험동에서 표준 중량 충격원과 실충격원에 대하여 바닥충격음을 측정하고 이를 이용하여 해외 평가 방법과 우리나라의 평가 방법을 비교 검토하였다. 또한 현행 바닥충격음 평가 기준의 대상 주파수 범위를 벗어나는 저주파수 대역의 음압레벨은 네텔란드의 저주파 소음 인지 곡선과 국내 연구자가 제안한 저주파 소음 기준안을 이용하여 평가하였다. 그 결과 기준 및 평가 산정 방법에 따라 성능 평가 결과가 상이하며, 바닥 진동의 지배 주파수 범위에서 모든 충격원에 대한 바닥충격음 가청 소음으로 인식하여 성가시게 느낄 가능성이 매우 크다. 현행 평가 기준의 단일수치 평가량 산정 방법은 충격원에 따라 상이한 음압레벨 스펙트럼 특성을 제대로 반영하지 못하며, 바닥의 진동 거동 지배 주파수를 포함하는 저주파수 대역의 음압레벨을 고려하지 않고 있어 바닥충격음에 대한 평가 결과와 사람의 인지 수준에 차이가 발생할 수 있다. 따라서 충격원에 따른 음압레벨의 스펙트럼 특성과 저주파수 대역의 음압레벨을 반영할 수 있도록 현행 기준의 평가 방법을 보완할 필요가 있다.

바닥충격음 평가방법 중 단일수치평가량과 dB(A) 비교 (Comparison of Rating Methods for the Floor Impact Noise)

  • 박철용;장동운
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.612-615
    • /
    • 2006
  • In this study, we compared and analyzed the floor impact noise insulation performance produced by the rating methods. The rating methods are using reversed A-weighting curve, A-weighted sound pressure levels(dB(A)). The results of this study are(1)dB(A) by the specified frequency is 0.5dB(A) at light weight and 2.5dB(A) at heavy weight upper than all pass dB(A)(2)the rating using reversed A-weighting curve is 5dB lower than dB(A)(3)the number of rating using reversed A-weighting curve mainly depends on impact noise pressure level of 63Hz in heavy weight but dB(A) does not.

  • PDF

중량바닥충격에 의한 소음 및 진동 특성 (Noise and Vibration Characteristics by Heavy-weight Floor Impact)

  • 서상호;송희수;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.919-922
    • /
    • 2003
  • The correlation between noise and vibration by a heavy-weight floor impact was studied. The triggering technique was used for increasing the reliability and stability to measure the level of sound pressure, sound intensity and vibration acceleration. The simple finite element and rigid body analysis method were suggested to calculate the natural frequencies of the multi-layer floor system. The result show that the isolation material adapted to reduce the light-weight floor impact noise, causing the natural frequency lower, make resonance with dominant driving frequency, and increase the noise level very sharply. Therefore the noise level Peak in the region of low frequency, below 63Hz, would be related with the natural frequencies of the floor system.

  • PDF

거주자의 거동으로 발생하는 바닥진동의 층간 전달 및 바닥충격음의 음압레벨 특성 평가 (Characteristics of Transmission of Floor Vibration and Floor Impact Noise Due to Human Activities)

  • 이민정;최현기
    • 한국소음진동공학회논문집
    • /
    • 제27권1호
    • /
    • pp.5-13
    • /
    • 2017
  • Noise complaints among neighbors in apartment building are mainly caused by floor impact noise that is structure born noise due to occupant induced floor vibration. To control this noise problems many researchers have investigated floor systems and finishing materials. Light-weight impact noise affects by finishing materials, but heavy-weight impact noise induced by heel impacts during normal walking or jumping of children is concerned with structural system and floor vibration. To figure out the characteristics of floor impact noise and transmission of floor vibration due to human activities, vibration tests were conducted in apartment buildings. Impact hammer, heel drop and walking activities were loaded at center of upstairs living room, and accelerations of slabs for both upstairs and downstairs and sound pressure levels for downstairs were measured. The acceleration ratio of transmitted floor vibration to downstairs and human induced vibration in upstairs was between 0.5 and 1.0 according to slab size, wall, and load type. And floor impact noise occurred in the range of natural frequency of slab.

Heavy-impact sound insulation performance according to the changes of dry flooring structure in wall structure

  • Cho, Jongwoo;Lee, Hyun-Soo;Park, Moonseo;Lim, Hohwan;Kim, Jagon
    • 국제학술발표논문집
    • /
    • The 7th International Conference on Construction Engineering and Project Management Summit Forum on Sustainable Construction and Management
    • /
    • pp.89-98
    • /
    • 2017
  • The floor heating method generally uses a wet construction method including the installation of resilient material, lightweight foam concrete, heating piping, and finishing mortar. Such a wet construction method not only delays other internal finishing processes during curing period for two mortar pouring process, but also has a disadvantage that it is difficult to replace the floor heating layer when it deteriorated because it is integrated with the frame. Dry floor heating construction method can be a good alternative in that it can solve these defects. Conversely, when it applied to the wall structure that is vulnerable to the interlayer noise compared with the column-beam structure, the question about the heavy-impact sound(HIS) insulation performance is raised. Therefore, conventional dry floor heating method is hard to apply to the wall structure apartments. Therefore, for the purpose to improve the applicability of dry floor heating method in wall structure apartments, this study investigated the change of floor impact sound, especially HIS insulation performance which is one of the required performance for the floor structure. This study tried to examine whether the change of heavy-impact sound pressure level(SPL) shows a tendency at the significant level according to the shape and mass of the floor structure. Through filed experiments on wall structure apartment, this study confirmed that the form of the raised floor shows better HIS insulation performance than the fully-supported form. In addition, it was also confirmed that the HIS insulation performance increases with the mass on the upper part. Moreover, this study found the fact that a mass of about 30 kg/m2 or more should be placed on the upper structure to reduce the heavy-impact SPL according to the bang machine measuring method. Although this study has a limit due to insufficient experiment samples, if the accuracy of this study is increased, it will contribute to the diffusion of dry floor heating by setting the HIS insulation performance target and designing the dry floor heating structure that meets the target.

  • PDF

공동주택에서 중공 슬래브 바닥의 차음 특성에 관한 연구 (A Study on the Characteristics of Sound Insulation at the Circular Voided Concrete Floor in the Multi-Housing)

  • 손철수
    • 한국주거학회논문집
    • /
    • 제11권1호
    • /
    • pp.171-181
    • /
    • 2000
  • The purpose of the resent research is to investigate the characteristics of sound insulation at the circular voided concrete slab in the multi-housing. In order to do this research, the method for field measurement of floor impact sound level was used following the Korea Standard F2810-1996. For the multi-housing, three kinds of circular voided concrete slabs are used to measure the characteristics of sound insulation.The results are as follows; 1.The main factor affecting the characteristics of sound insulation at the circular voided concrete slab in the multi-housing is sound-absorbing materials in the circular tube. 2. The main factor to effect the difference of sound pressure level is circular tube in the concrete slab. 3. The forms of circular tubes effect the characteristics of sound insulation at the circular tube. 4. Sound Pressure Level resulting from the piping direction of circular tubes in little different to octave band level.More study will be needed about the depth and distance of sound insulation materials, and the components of sound insulation materials for the multi-housing.

  • PDF

마감모르타르 물결합재비에 따른 바닥충격음 특성 변화 (Characteristics of the floor impact sound by water to binder ratio of mortar)

  • 이원학;한찬훈
    • 한국음향학회지
    • /
    • 제40권6호
    • /
    • pp.671-677
    • /
    • 2021
  • 본 연구의 목적은 마감모르타르의 물결합재비가 공동주택 바닥충격음에 미치는 영향을 조사하는 것이다. 이를 위하여 동일한 동탄성계수를 지닌 Expanded Polystyrene(EPS) 완충재와 52 %, 66 %, 72 % 의 물결합재비를 가진 모르타르를 활용하여 뜬바닥구조를 시공하였으며, 표준실험동에서 바닥충격음을 측정하였다. 실험결과, 경량충격음에 있어서는 물결합재비 52 % 일 때, 밀도가 높은 관계로 경량충격음 전달특성이 높게 나타났다. 마감모르타르의 물결합재비가 높아지면 완충재 상부층 질량이 낮아지고, 이로 인해 뜬바닥구조의 고유진동수가 63 Hz 대역으로 이동하게 되면서 중량충격음의 음압레벨이 높게 나타났다. 이를 통하여 마감모르타르의 물결합재비가 중량충격음에 미치는 특성을 규명하였다.

F.R.P 재료 보강에 의한 신개념 중량충격음 저감대책 (Heavy-weight Impact Noise Reduction of Concrete Slab Reinforcement Using F.R.P)

  • 정정호;유승엽;이평직;전진용;조아형
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.383-386
    • /
    • 2005
  • Low frequency heavy-weight impact noise is the most irritating noise in Korean high-rise reinforced concrete apartment buildings. This low frequency noise is generated by foot traffic due to the fact that Koreans do not wear shoes at home. The transmission of the noise is facilitated by a load bearing wall structural system without beams and columns which is used in these buildings. In order to control low frequency heavy-weight impact noise, floating floors using isolation materials such as glass-wool mat and poly-urethane mat are used. However, it was difficult to control low frequency heavy-weight impact sound using isolation material. In this study, reinforcement of concrete slab using beams and plate was conducted. Using the FEM analysis, the effect of concrete slab reinforcement using FRP(fiber-glass reinforced plastic) on the bang machine impact vibration acceleration level and sound were conducted at the standard floor impact sound test building. The $3{\sim}4dB$ floor impact vibration acceleration level and impact sound pressure level were reduced and the natural frequency of slabs were changed.

  • PDF