• Title/Summary/Keyword: Floor heating system

Search Result 278, Processing Time 0.025 seconds

Research on Paper Board Banja With Woomul(井) Structure of Royal Palaces in the Joseon Dynasty (조선시대 궁궐건축의 우물천장 구조 종이반자 연구)

  • Lee, Jong-Seo
    • Journal of architectural history
    • /
    • v.32 no.1
    • /
    • pp.61-72
    • /
    • 2023
  • Korean architecture classifies Banja (the decorated flat of the ceiling visible from the inside) of Royal Palaces into two types: Woomul(water-well, 井) banja, which inserts rectangular wooden board into lattice frame, and paper banja, which applies paper to the flat ceiling. Such classification was established in the 19th century. Before that, Banja was classified according to what was inserted into the lattice frame, either wooden or paper board. At first, the banja that used paper board was widely installed regardless of the purpose or nobility of the building. However, since the 17th century, the use of paper board banja became mostly restricted to Ondol (Korean floor heating system) rooms which are characterized by private usage and the importance of heating, and it was considered inferior to wooden board banja in terms of rank or grace. The contemporary paper banja was mainly installed in low-rank ondol rooms until the late 19th century to early 20th century, when roll-type wallpaper was introduced from the West and the paper banja came to decorate the King's and Queen's bedrooms. The traditional paper board banja benefits heat reservation, reduces the weight of the ceiling, and allows the adjustment of the lattice frame size. Furthermore, it can feature unique artistry if covered with blue, white, or red Neung-hwa-ji (traditional flower pattered paper).

Comparative Analysis of Rural and Urban Residential Interior Elements Affecting Physically Disabled's Independence (재가지체장애인의 자립을 저해하는 농촌과 도시의 주거실내 환경요소에 대한 비교연구)

  • Park, Ji-Young;Jang, Mi-Seon;Lee, Yeun-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.1
    • /
    • pp.132-141
    • /
    • 2016
  • For those with disabilities, the residential area is the primary place to adapt the disabilities. Since the quality of the area gives a critical impact on their quality of life, it is essential to finding the measures to create the residential environment that supports their independence. In this regard, this study aimed to compare and analyze the interior elements of the houses that hinder the independence of the physically handicapped in the rural and urban areas, and conducted a survey on a total of 80 physically challenged in Seoul and Yeongwol (40 for each area). As a result, the respondents answered that the houses where they are currently living are hindering their independence regardless of area, and there were regional differences in the level of inconvenience with the size of living room, size of utility room, location of room, lighting and heating environment, ventilation system, deteriorated wallpapers and finishing materials, threshold and floor level difference and humidity control. This study has significance by providing the realistic measures to improve the housing environment of the physically challenged living in the rural and urban areas to be customized to them to increase their quality of life.

Study on the Development of the Mobile Pig Nursery for Early Weaned Piglet (조기이유 자돈 사육을 위한 이동식 자돈사 개발에 관한 연구)

  • 유용희;이덕수;정일병;이진우;전병수;한정대
    • Journal of Animal Environmental Science
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 1998
  • The objective of this study was conducted to develope a mobile pig nursery(MPN) for segregation of early weaned piglet. The units of MPN was consisted of 4 rectangle-type pens, 1 workroom, 2 doors, 3 windows, 1 air-inlet, 1 exhaust fan, and 1 cooling and heating system. Total of 40 piglet were weaned at 7 days of age. The period of the feeding test was 63 days. The results obtained are as follows: 1. The insulation thickness was 70, 70 and 50 mm of roof, floor and wall, respectively. R-value was 15.32 and 10.32 of roof and wall, respectively. 2. Exhaust fan( 30.48) was installed near back door 40cm from the bottom. When exhaust fan speeds were 15, 20, 30 and 35%, Air ventilation was required 9.75, 7.07, 1.72, 1.45 minutes of respectively. 3. Average temperature in the MPN was able to maintain 27∼28$^{\circ}C$ from 7∼28 days of age, 24∼25$^{\circ}C$ from 35∼56 days of age and 20∼21.5$^{\circ}C$ from 56∼70 days of age. 4. Average daily gain, feed intake and feed conversion were 420.6g, 761.5g, 1.81 respectively.

A Study on Characteristics of Koreans' Housing Life Living in China (중국 거주 한국인의 주생활특성 연구)

  • Cho, Sung-Heui;Son, Jin-Hee
    • Journal of the Korean housing association
    • /
    • v.16 no.6
    • /
    • pp.9-19
    • /
    • 2005
  • It is possible to explain the design, the meaning, and the use of domestic space by comparing different cultures. The characteristics of Koreans' housing life living in western cultures has already been studied extensively. Because of political reasons, however, the characteristics of Koreans' housing life living in Chinese culture has hardly been studied at all. The purpose of this study was to find out the characteristics of succession and transformation of domestic housing culture. The data was collected by questionnaire methods from fifty Korean households and eleven Chinese households. Individual interviews and actual surveys, including taking pictures were also used for data collection. The results of this study were as follows (1)An analysis of heating system usage behaviors showed the importance of heated floors, known as Ondol, is one of the enduring characteristics of domestic habits. (2)In the sitting style, the traditional sitting on the floor was shown in living room. (3)Regarding room usage behavior, Korean households were centered around the living room in chinese houses. (4)An analysis of space organization preferences with respect to common spaces revealed that Korean households tend to prefer the open plan of common spaces.

Actual conditions on the Living Environment of Small-scale Group-homes for the Elderly (고령자용 소규모 그룹홈의 생활환경 실태)

  • Kim, Hyun-Jin;An, Ok-Hee
    • Journal of the Korean housing association
    • /
    • v.19 no.3
    • /
    • pp.21-29
    • /
    • 2008
  • To investigate the actual conditions on the living environment of group-homes for the elderly and their living environment, 4 group-homes were surveyed. As the results, conditions of location for the group-home of the elderly looked positive, on the other hand, safety for criminal prevention, accessability and convenient facilities were not on level satisfied. The average area of each space in the group-home indicated that the bed room was $11.21\;m^2$, the living room $28.13\;m^2$, the kitchen $23.59\;m^2$, and the bath room had an integrated type of bath room and toilet $7.63\;m^2$. The physical environments of each space in the group-home were investigated, In bed room, door, windows and illumination were relatively good but safety was extremely inferior. Living room mostly looked good except the doorsill which needs refurbishment. In kitchen, cooking table, windows, illumination, ventilator were somewhat satisfactory but gas-warning device should have been installed. In addition, in bath room and toilet, location, door, window, illumination and finished material were satisfactory. But the stepped difference between the bath room and other space, safety-bar, emergency bell and floor heating system were seriously deteriorated and must be improved for the safety of the elderly. Conclusively, living environment of group-home for the elderly is mainly satisfactory but it was necessary to take a consideration for their safety.

Suggestion of the Characteristics of Element Technology and the Standard Model through the Comparison of Domestic Zero-energy Houses (국내 에너지제로하우스 비교를 통한 요소기술 특성 및 표준 모델 제시에 관한 연구)

  • Lee, Chung-Kook;Lee, Jeong-Cheol;Kim, Sang-Su;Suh, Seung-Jik
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.2
    • /
    • pp.27-35
    • /
    • 2012
  • Five zero energy house models developed in Korea for the purpose of the energy performance were compared and analyzed in the study. The standard passive house model applying common technology and efficient energy performance elements was proposed. Standard passive house 5 models have been developed commonly aiming at 100% energy saving, applying high-performance and high-efficiency exterior thermal insulation, using 3 low-e coated window system, and targeting average 0.65 ACH to enhance privacy. Energy recovery ventilators and dry and cold radiant heating floor has been partially applied. Eco-design techniques such as the awning device, heat insulating door, using natural light have been used. Solar and geothermal systems as the application of renewable energy technologies have been commonly applied. And fuel cells were applied to a partial model. The standard model based on common technical elements and average performance of each element and obtained from five model analysis has been proposed in the study.

An Investigation on Determinants of Apartment Price in Ilsan Area (일산지역의 공동주택 평당매매 가격결정 특성에 관한 연구)

  • Jang, Han-Sub;Yoo, Seon-Jong
    • Journal of the Korean housing association
    • /
    • v.18 no.6
    • /
    • pp.35-44
    • /
    • 2007
  • The purpose of this paper is to find out the factors affecting the apartment price given three sets of variables such as characteristics of apartment building, apartment site, and location. Data of 1,579 housing units in 224 apartment complex sites in Ilsan city were selected from the housing information of four public and private housing sources in 2006. The first set of variables for physical features include housing size (pyoung), preferring-floor, building orientation, heating system and structure of entrance. The second set of variables for building were number of housing units, built year and rank of construction company. The third set of variables for location were distance from number of school, the subway station, distance of department store and park. For the analysis, the hedonic price model, which was one of the methods to estimate social convenience, was used along with the SPSS statistical program and regression analysis. The results are as follows, Firstly, in the structural characteristic variables, it was analyzed that all of the variables except facing affected the apartment price. Secondly, In the site characteristic variables, unusually all of the variables were not affected the apartment price in Ilsan city. Finally, the locational characteristic variables number of school, the subway station, distance of department store and park affected the apartment price. In case of Ilsan city, educational facilities was likely to positively contribute to the price of apartment.

A Study on the Reference Building based on the Building Design Trends for Non-residential Buildings (건축물 설계현황 분석을 통한 국내 비주거용 표준건물의 설정에 관한 연구)

  • Jeong, Young-Sun;Jung, Hae-Kwon;Jang, Hee-Kyung;Yu, Ki-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.1-11
    • /
    • 2014
  • The Korean government plans to introduce the building energy performance standard which regulates the annual energy consumption of buildings. This paper aimed to set up the reference building from database based on the building design trends for non-residential buildings. We surveyed the design data of 435 non-residential buildings which were granted building permission from 2007 to 2011. And we conducted estimation on the heating & cooling load and the energy consumption of the reference building using ECO2 program. From results, the reference building of non-residential buildings was office building which had a total 7 floors and $20,838m^2$ gross floor area. And it suggests the design reference data of building envelope, HAVC, heat source equipment and lighting system for the reference building. The total annual energy use of the reference building was $151.9kWh/m^2yr$.

Energy Performance Evaluation of Low Energy Houses using Metering Data (실측데이터를 이용한 저에너지주택의 에너지성능평가)

  • Baek, Namchoon;Kim, Sungbum;Oh, Byungchil;Yoon, Jongho;Shin, Ucheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.369-374
    • /
    • 2015
  • This study analyzed analyzes the energy performance of six houses in Daejeon completed which were built in 2011. Observed The observed houses, which were all designed and constructed inof the same size and structure, are were highly insulated with triple Low-E coating windows; the insulation level of the walls is was $0.13W/m^2K$ and that of the roof is was $0.10W/m^2K$. As electric houses, all of the energy supplied to the houses, including for cooking, is was supplied by electricity. A and 3~4 kWp of photovoltaic system and a 3~5 kW of ground source heat pump (GSHP) were installed in each house tofor providing provide space heating/and cooling and hot water are installed. We constructed a Web-based remote monitoring system in order to understand energy consumption and the dynamic behavior of the energy system. T, and the results of our metering data analysis of 2013 are as follows. First, the annual residential energy consumption is was 4,400 kWh (${\sigma}=1,209$) and GSHP energy consumption is was 5,182 kWh (${\sigma}=1,164$). Second, residential energy consumption ranked highest in average energy usage, with at 45% of the total, followed by heating with at 30%, hot water supply with at 17% and cooling with at 6%. Third, the average energy independence rate is was 51.8%, the GFA (Gross gross floor area) criteria average energy consumption unit is was $48.7kWh/m^2yr$ (${\sigma}=10.1$), and the net energy consumption unit (except the energy yield of the PV systems) is was $24.7kWh/m^2yr$ (${\sigma}=8.8$).

Emission Characteristics of Volatile Organic Compounds from Building Flooring Materials (건축용 바닥재로부터의 휘발성유기화합물 방출특성)

  • Yun, Joong-Seop;Lee, Myong-Hwa;Eom, Seok-Won;Kim, Min-Young;Kim, Jong-Ho;Kim, Shin-Do
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.973-978
    • /
    • 2010
  • The emission of volatile organic compounds (VOCs) from building materials is one of great concerns due to maintain airtight condition of a building to reduce energy consumption, and it causes the deterioration of indoor air quality. Therefore, the emission characterization of VOCs from building materials is necessary to improve indoor air quality. Emission characteristics of VOCs from a plywood flooring that is one of the most commonly used materials in an under-heating system, and from an adhesive that is generally used to stick a plywood flooring to a concrete floor were investigated using an emission chamber test in this study. It was found that the VOCs emission factor was dependent upon and proportional to indoor temperature, and the emission characteristics were closely related to the existing places and conditions of VOCs sources inside the building materials. Maximum emission factors of hexane and toluene from building materials were generally observed at the beginning, however, only that of toluene from a plywood flooring was shown after 6 hours from the beginning. It could be considered that the existing place and condition of toluene source inside a plywood flooring could influence on the VOCs emission. From this study, bake-out time more than 72 hours could be recommended before moving in to avoid the exposure to high concentration of VOCs emitted from an under-heating system.