• Title/Summary/Keyword: Floor covering

Search Result 45, Processing Time 0.025 seconds

Formula for Equivalent Impulsive Force to Predict Vibrational Response of High-frequency Staircases (고진동수 계단의 진동응답 산정을 위한 등가임펄스 산정식 제안)

  • Kim, Na Eun;Lee, Cheol Ho;Kim, Sung Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.2
    • /
    • pp.181-193
    • /
    • 2015
  • High-frequency staircases are widely used nowadays to meet aesthetics and functionality needed in modern architecture. Unfortunately, no design guide is available in domestic practice to predict response or evaluate the vibration performance of high-frequency staircases. SCI-P354 published by the Steel Construction Institute of UK provides the formula for effective impulsive force. However, this formula was shown to overestimate the response of high-frequency staircases excited by fast ascending and descending over 2.2Hz pace frequency because it was developed based on the walking test in a slow pace frequency. This study proposes a semi-analytical formula to predict the response of stiff staircases based on analytical and experimental studies of response acceleration for various walking frequencies covering 1.4~4.5Hz.

Validation of Load Calculation Method for Greenhouse Heating Design and Analysis of the Influence of Infiltration Loss and Ground Heat Exchange (온실 난방부하 산정방법의 검증 및 틈새환기와 지중전열의 영향 분석)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Horticultural Science & Technology
    • /
    • v.33 no.5
    • /
    • pp.647-657
    • /
    • 2015
  • To investigate a method for calculation of the heating load for environmental designs of horticultural facilities, measurements of total heating load, infiltration rate, and floor heat flux in a large-scale plastic greenhouse were analyzed comparatively with the calculation results. Effects of ground heat exchange and infiltration loss on the greenhouse heating load were examined. The ranges of the indoor and outdoor temperatures were $13.3{\pm}1.2^{\circ}C$ and $-9.4{\sim}+7.2^{\circ}C$ respectively during the experimental period. It was confirmed that the outdoor temperatures were valid in the range of the design temperatures for the greenhouse heating design in Korea. Average infiltration rate of the experimental greenhouse measured by a gas tracer method was $0.245h^{-1}$. Applying a constant ventilation heat transfer coefficient to the covering area of the greenhouse was found to have a methodological problem in the case of various sizes of greenhouses. Thus, it was considered that the method of using the volume and the infiltration rate of greenhouses was reasonable for the infiltration loss. Floor heat flux measured in the center of the greenhouse tended to increase toward negative slightly according to the differences between indoor and outdoor temperature. By contrast, floor heat flux measured at the side of the greenhouse tended to increase greatly into plus according to the temperature differences. Based on the measured results, a new calculation method for ground heat exchange was developed by adopting the concept of heat loss through the perimeter of greenhouses. The developed method coincided closely with the experimental result. Average transmission heat loss was shown to be directly proportional to the differences between indoor and outdoor temperature, but the average overall heat transfer coefficient tended to decrease. Thus, in calculating the transmission heat loss, the overall heat transfer coefficient must be selected based on design conditions. The overall heat transfer coefficient of the experimental greenhouse averaged $2.73W{\cdot}m^{-2}{\cdot}C^{-1}$, which represents a 60% heat savings rate compared with plastic greenhouses with a single covering. The total heating load included, transmission heat loss of 84.7~95.4%, infiltration loss of 4.4~9.5%, and ground heat exchange of -0.2~+6.3%. The transmission heat loss accounted for larger proportions in groups with low differences between indoor and outdoor temperature, whereas infiltration heat loss played the larger role in groups with high temperature differences. Ground heat exchange could either heighten or lessen the heating load, depending on the difference between indoor and outdoor temperature. Therefore, the selection of a reference temperature difference is important. Since infiltration loss takes on greater importance than ground heat exchange, measures for lessening the infiltration loss are required to conserve energy.

The Growth Rate of Salix Gracilistyla Miq. and its Effect of Protecting Soil from Dispersion Depending on the Planting Method Applied to Shore-marginal Slope (습지 수제부에서 삽목방법에 따른 갯버들 생장율 및 토양 유실 억제 효과)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.3
    • /
    • pp.56-68
    • /
    • 2003
  • The main purpose of this study was to verify the shore margin protection effect of the root system of Salix gracilistyla Miq. developed from direct sticking cuttings on wetland, through the measurement of root growth and comparison of soil slaking rate depending on the planting method applied to shore-marginal slope. Comparison of growth rate and soil dispersion rate was made between five planted slope and one naked slope. The planting methods applied to the planted slope were (a) horizontally layed burying of stick(45cm) bundle (b) horizontally layed covering the slope with sticks (c) horizontally fencing with normal cuttings(20cm) (d) elected sticking of normal cutting at equal distances (e) random scattering short cuttings(3-4cm). As results, the most effective planting method was horizontally layed burying, and in order to increase its efficiency scattering the live stem chips in 2-3cm on the slope is recommended. The growth of root was negatively regressive to the distance from water floor.

Dyeability of Low-melting Hybrid Polyester at Low Temperature (저융점 폴리에스테르 복합사의 저온 염색성)

  • Hwang, Ji-Hyun;Kim, Chang-Nam;Ma, Jin-Suk;Oh, Hae-Sun;Yoon, Nam-Sik
    • Textile Coloration and Finishing
    • /
    • v.24 no.2
    • /
    • pp.113-120
    • /
    • 2012
  • Jacquard floor covering could be prepared from low-melting/regular sheath-core hybrid polyester, where the fiber is dyed in yarn state. With regard that the expected high shrinkage of the hybrid polyester in water makes problems in yarn dyeing, low-temperature dyeing properties of the hybrid polyester were studied. The rate of shrinkage of low-melting hybrid polyester exceeds 9% in hot water above $90^{\circ}C$, at such condition, cheese yarn dyeing is very difficult. Although disperse dyes exhaust in a relatively high speed on low-melting hybrid polyester, diffusion of these dyes to the core regular polyester was extremely slow under $90^{\circ}C$. Foron Blue E-BL 150, an anthraquinone E-type disperse dye, showed appreciable diffusion after 48hrs dyeing at $90^{\circ}C$. The fastness to rubbing and drycleaning were improved by one grade after reduction cleaning.

Current on the Heat Loss in Greenhouses during Winter Season - Case Study Based on Gyeongnam Area - (동절기 온실의 열 손실에 관한 실태조사 - 경남지역을 중심으로 -)

  • Im, Jae Un;Yun, Sung Wook;Kim, Hyeon Tae;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.73-79
    • /
    • 2013
  • An experiment was conducted to study incidences of heat loss in greenhouse in Gyeongnam province using thermal imaging camera in order to determine ways minimizing greenhouse heat loss. Measurements of this work showed that temperature differences between two experiment zones before and after installation of thermal curtains were about $2.0{\sim}3.0^{\circ}C$ and $1.0{\sim}2.0^{\circ}C$ respectively. There was a high correlation between the temperature data measured using a thermal imaging camera and a temperature sensor. There was no serious difference among areas, but between places on the first and second floor with thermal curtains for heat insulation, there was a relatively larger heat loss on the first floor than the second floor. Then in general the greenhouse types had no particular bearing on this matter, there was a relatively large heat loss in the parts of side wall window, the gaps and the parts folded of horizontal thermal curtains, the gutter parts, and the gaps of thermal curtain in the side wall window and facade back side for heat insulation, aren't completely sealed. It was found that there was a substantial heat loss due to infiltration through cracks on covering material, doors, ventilating openings, roof gables and floors, in particular.

Fate of Fenitrothion aerially applied to the Pine Forest (항공살포에 따른 Fenitrothion의 산림환경 중 행적)

  • Kim, Dae-Gyun;Kim, Chan-Sub;Lee, Byung-Moo;Choi, Ju-Hyeon;Park, Jae-Eup
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.4
    • /
    • pp.322-327
    • /
    • 2012
  • Fate of fenitrothion aerially sprayed to control pine wood nematode (Bursaphelenchus xylophilus) was studied in a forest of Haman area. And the monitoring of fenitrothion was conducted in a stream flowed from forest area of Gijang sprayed fenitrothion. Fenitrothion 50% EC was diluted 100 times and applied two or three times using helicopter in Haman and Gijang, respectively. Average fenitrothion deposits on forest floor ranged from 6% of standard aerial application rate. Following to the second application, fenitrothion deposits in the pine needle ranged from 0.6 to 0.9 mg/kg and then rapidly decreased to 0.01 mg/kg after 109 days. Deposits on the plant washed off by rainfall and reached to soil surface was 1.3% of the application rate. All of fenitrothion on the ground resided in the forest floor covering the soil surface, where fenitrothion residues were decreased to a tenth at 109 days after the second application, but they were not detected in sol beneath it. And the only low level of fenitrothion residues, 0.0009 mg/L, was detected in runnel of the experimental forest just after aerial application. The concentration of fenitrothion in effluent from Gijang area was less than detection limit (0.0001 mg/L) during the entire period.

A Study on the Linoleum of the Deoksugung and Changdeokgung Palaces in the Early 20th Century: focusing on its manufacturing process, characteristics, and usage (20세기 초 덕수궁·창덕궁에 유입된 리놀륨(Linoleum) 바닥재 연구: 리놀륨의 제작 방식과 특성 및 사용을 중심으로)

  • Choi, Jihye
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.1
    • /
    • pp.18-31
    • /
    • 2021
  • Linoleum is a resilient, hygienic, and eco-friendly floor covering. It was developed in England by Frederick Walton in 1863. Made of cork flour, linseed oil, and burlap as its main materials, the flexible and waterproof linoleum became globally popular in the early 20th century. Unlike the vinyl coverings, the burlap-backed linoleum was used not only in commercial spaces but also in household areas like kitchens, bathrooms, and even living rooms. As a global product, linoleum was imported and used in Korean palaces like Deoksugung and Changdeokgung in the early modern period. According to the record Deoksugung Won-Ahn, linoleum was applied to the major buildings, including Hamnyeongjeon, Deokhongjeon, and Jeonggwanheon, and various other venues. The linoleum used in these places are mainly monochrome blue and brown color, which probably means that they are from England. The trade records in the early 20th century show that linoleum was imported mainly from England and America. The Ewangjik building floor plan in the Changdeokgung Palace shows that linoleum was used extensively. There are even some originals, which were laid in 1920 and left in the Changdeokgung Palace. When Daejojeon and Huijeongdang were rebuilt in 1920, the interior was outfitted with western features and linoleum was used in areas such as bathrooms, the tonsorial parlor, and one of the rooms on the west side of Huijeongdang. In situ in the Daejojeon and Huijeongdang areas in the Changdeokgung Palace are monochrome, patterned black, and stylized floral tile patterned, which are closely similar to American products made by ALC and Armstrong company. This study will help us better understand linoleum's characteristics, its uses and the material itself. It will also form the basis for the restoration of Changdeokgung Palace as well as other modern interiors with linoleum flooring in the future.

Fate of Acetamiprid and Imidacloprid aerially applied to the Pine Forest (항공살포에 따른 Acetamiprid와 Imidacloprid의 산림환경 중 행적)

  • Kim, Chan-Sub;Kwon, Hye-Young;Son, Kyeong-Ae;Gil, Geun-Hwan;Kim, Jin-Bae
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.4
    • /
    • pp.315-321
    • /
    • 2012
  • Fate of acetamiprid and imidacloprid aerially sprayed to control pine wood nematode (Bursaphelenchus xylophilus) were studied in a forest of Haman area. Acetamiprid 20% SL or imidacloprid 20% DC were diluted 100 times and applied two times as rate of 50 L/ha using an aircraft of Bell 206 L helicopter. Average acetamiprid deposits on forest floor ranged from 2 to 4% of standard aerial application rate. Following to the second application, acetamiprid deposits in the pine needle ranged 1.8~8.5 mg/kg and then gradually decreased to 1.2~2.1 mg/kg after 48 days. Deposits on the plant washed off by rainfall and reached to soil surface was ca. 17% of the application rate. All of acetamiprid on the ground resided in the forest floor covering the soil surface, where acetamiprid residues were decreased to a quarter at 48 days after the second application, but they were not detected in soil beneath it. And the only low level of acetamiprid residues, 0.0003 mg/L, was detected in the reservoir nearby the experimental forest on the day of aerial application. The acetamiprid detection was presumably due to spray drift. And average imidacloprid deposits on forest floor ranged from 1 to 3% of standard aerial application rate. Following to the second application, imidacloprid deposits in the pine needle analysed very low concentration of 0.1 mg/kg, but the amount of imidacloprid in wash-off in standard and two-fold treatment were ca. 8% and 4% of the application rate, respectively. Most of imidacloprid on the ground also resided in the forest floor, where imidacloprid residues were decreased to a twentieth at 111 days after the second application, and they were detected below 0.5% of the application rate in sol beneath it. And the low level of imidacloprid, 0.0003~0.0017 mg/L, were detected in the streams in the experimental forest. It was not to the level of contamination concerns.

Change of Green Space Arrangement and Planting Structure of Apartment Complexes in Seoul (서울시 아파트단지의 녹지배치 및 식재구조 변화 연구)

  • Lee, Dong-Wook;Lee, Kyong-Jae;Han, Bong-Ho;Jang, Jae-Hoon;Kim, Jong-Yup
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.4
    • /
    • pp.1-17
    • /
    • 2012
  • This study was carried out to propose the improved method by analyzing the change of green space arrangement and planting structure of apartment complexes in Seoul. 12 survey sites, which have obvious differences, were selected by reflecting the change of floor area ratio, underground parking place, and green space ratio. We divided the survey sites into four types that high green ratio(over 40%) apartment on natural ground, low green ratio(under 40%) apartment on natural ground, low green ratio(under 40%) apartment on artificial ground, and high green ratio(over 40%) apartment on artificial ground each period based on green space ratio and ground structure, plant crown volume, planting density, and planting pattern. The main factors of change of green space arrangement were green space ratio and ground structure. The Green space ratio was changed by the floor area ratio with constructing underground parking place and floor area ratio was adjusted by government policy and economic status. Average width of front green area has been changed from 10.0m in high green ratio apartment on natural ground for 3.5m, 2.7m, and 4.5m each period. The average width of the buffer green area has been changed from 15.0m in high green ratio apartment on natural ground of 7.7m, and 2.7m by extending parking place in the low green ratio apartment of artificial ground, so buffer green areas have been reduced and disconnected. So buffer green area in apartment complexes has been extended that the average width of the buffer green area was 3.8m caused by growing recognition of green since 2001. The ratio of native plant in canopy layer was increased from 45.1 % in the case of the high green ratio apartment of natural ground in 1980~1983 to 55.6%. Average plant crown volume increased from $1.27m^3/m^2$ in high green ratio apartment on natural ground for $3.47m^3/m^2$ in a low green ratio apartment on natural ground. But average plant crown volume is $0.27m^3/m^2$ in the high green ratio apartment of the artificial ground plant density of canopy layer was changed from 5 individuals per $100m^2$ to 14.5 individuals per $100m^2$. We should construct the buffer green area with natural ground and get the function of ecological and beautiful environment regarding to garden concept in case of front green area, width 4.5m. We should get the function of increasing green volume by multi-layer planting with shade woody species and flower woody species in case of back-side green area, width over 5.0m. We should get the function of covering the wall and increasing green landscape by planting with high woody species in case of side green area. We should apply the ecological planting technique to buffer green area and connect buffer green area to inner green area in apartment complexes.

Analysis of Building Vulnerabilities to Typhoon Disaster Based on Damage Loss Data (태풍 재해에 대한 건물 취약성의 피해손실 데이터 기반 분석)

  • Ahn, Sung-Jin;Kim, Tae-Hui;Son, Ki-Young;Kim, Ji-Myong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.6
    • /
    • pp.529-538
    • /
    • 2019
  • Typhoons can cause significant financial damage worldwide. For this reason, states, local governments and insurance companies attempt to quantify and mitigate the financial risks related to these natural disasters by developing a typhoon risk assessment model. As such, the importance of typhoon risk assessment models is increasing, and it is also important to reflect local vulnerabilities to enable sophisticated assessments. Although a practical study of economic losses associated with natural disasters has identified essential risk indicators, comprehensive studies covering the correlation between vulnerability and economic loss are still needed. The purpose of this study is to identify typhoon damage indicators and to develop evaluation indicators for typhoon damage prediction functions, utilizing the loses from Typhoon Maemi as data. This study analyzes actual loss records of Typhoon Maemi provided by local insurance companies to prepare for a scenario of maximum losses. To create a vulnerability function, the authors used the wind speed and distance from the coast and the total value of property, construction type, floors, and underground floor indicators. The results and metrics of this study provide practical guidelines for government agencies and insurance companies in developing vulnerability functions that reflect the actual financial losses and regional vulnerabilities of buildings.