• Title/Summary/Keyword: Floor board

Search Result 78, Processing Time 0.024 seconds

Evaluation of Effective Dose and Exposure Levels of Radon in Office and Plant Buildings (일부 제조업 사업장의 사무 및 공장동에서의 라돈농도 수준 및 유효선량 평가)

  • Chung, Eun Kyo;Kim, Ki Woong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.1
    • /
    • pp.38-45
    • /
    • 2017
  • Objectives: Radon may be second only to smoking as a cause of lung cancer. Radon is a colorless, tasteless radioactive gas that is formed via the radioactive decay of radium. Therefore, radon levels can build up based on the amount of radium contained in construction materials such as phospho-gypsum board or when ventilation rates are low. This study provides our findings from evaluation of radon gas at facilities and offices in an industrial complex. Methods: We evaluated the office rooms and processes of 12 manufacturing factories from May 14, 2014 to September 23, 2014. Short-term data were measured by using real-time monitoring detectors(Model 1030, Sun Nuclear Co., USA) indoors in the office buildings. The radon measurements were recorded at 30-minute intervals over approximately 48 hours. The limit of detection of this instrument is $3.7Bq/m^3$. Also, long-term data were measured by using ${\alpha}-track$ radon detectors(${\alpha}-track$, Rn-tech Co., Korea) in the office and factory buildings. Our detectors were exposed for over 90 days, resulting in a minimum detectable concentration of $7.4Bq/m^3$. Detectors were placed 150-220 cm above the floor. Results: Radon concentrations averaged $20.6{\pm}17.0Bq/m^3$($3.7-115.8Bq/m^3$) in the overall area. The monthly mean concentration of radon by building materials were in the order of gypsum>concrete>cement. Radon concentrations were measured using ${\alpha}-track$ in parallel with direct-reading radon detectors and the two metric methods for radon monitoring were compared. A t-test for the two sampling methods showed that there is no difference between the average radon concentrations(p<0.05). Most of the office buildings did not have central air-conditioning, but several rooms had window- or ceiling-mounted units. Employees could also open windows. The first, second and third floors were used mainly for office work. Conclusions: Radon levels measured during this assessment in the office rooms of buildings and processes in factories were well below the ICRP reference level of $1,000Bq/m^3$ for workplaces and also below the lower USEPA residential guideline of $148Bq/m^3$. The range of indoor annual effective dose due to radon exposure for workers working in the office and factory buildings was 0.01 to 1.45 mSv/yr. Construction materials such as phospho-gypsum board, concrete and cement were the main emission sources for workers' exposure.

Species Identification of Wooden Members in the Youngsanjeon Hall of Sucknamsa Temple (안성 석남사 영산전 목부재의 수종 분석)

  • Park, Won-Kyu;Jeong, Hyun-Min;Kim, Sang-Kyu
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • The purpose of this study is to examine the species of wooden members used in the Youngsanjeon Hall of the Sucknamsa temple in Anseong, Korea. Ninety-five wood samples from pillars, head-penetrating ties, beams, corner rafter, rafter, floor board and other wood members were identified. Seven species identified were hard pine, exotic pine, Zelkova serrata, Ginkgo biloba, Diospyros, Quercus(Cerrus) and Pyrus spp. In the case of pillars, eight were hard pines and the others Zelkova and Pyrus. Species of angle rafter were Ginkgo biloba and Zelkova. and those of beams were one hard pine and one Zelkova. Two purlin samples were Quercus(Cerrus) and rafters were hard pines except one Ginkgo and one exotic pine. Roof-filling timbers were identified as Zelkova and Diospyros spp. The other samples of roof-filling timbers were all identified as hard pines. The use of Ginkgo and several hardwoods in addition to hard pines may indicate supply of local logs near the Sucknamsa temple.

Comparison of Abdominal Oblique Muscle Activity During Leg Raising in Hook-lying Position According to Surface Conditions (Hook-lying 자세에서 한쪽 다리 들기시 지지면의 안정성에 따른 복사근의 근활성도 비교)

  • Kim, Su-Jeong;Weon, Jong-Hyuck;Oh, Jae-Seop;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.13 no.3
    • /
    • pp.102-110
    • /
    • 2006
  • To improve trunk stability, various exercise protocols were introduced into the clinical field. Trunk and lumbar stability exercises on unstable surfaces are especially recommended to improve lumbar stability. The purpose of this study was to compare abdominal oblique muscle activity during leg raising in hook-lying position among 3 different type of surface conditions (on floor (F), vestibular board (VB), and foam roll (FR)). Sixteen able-bodied volunteers, who had no medical history of lower extremity or lumbar spine disease, were recruited for this study. Surface electromyography (EMG) activity was recorded from the internal and external oblique muscles of both sides. The normalized EMG activity was compared using a one-way repeated ANOVA. The results showed that the EMG activities of the internal oblique and external oblique of the lifted leg side during straight leg raising significantly increased under the FR condition when compared to the F condition. There was no significant difference of the EMG activity in abdominal oblique muscles between the VB and the FR conditions. The EMG activity of the internal oblique of supported leg side during the straight leg raising was significantly greater under the FR condition than the VB and F conditions (p<.05). The composition ratio of EMG activity of internal oblique muscles during straight leg raising was significantly increased under the FR condition. Therefore, straight leg raising exercise on foam roll in hook lying position could be beneficial to improve trunk and lumbar stability.

  • PDF

The Characteristics of Chinese Traditionality Expression in View of Spatial Elements at Restaurants in Beijing Area (베이징지역 레스토랑 공간구성요소에 나타난 중국 전통성 표현 특성 연구)

  • Yuan, DanDan;Oh, Hye Kyung
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.1
    • /
    • pp.163-171
    • /
    • 2016
  • The objectives of this study is to analyze the characteristics of Chinese traditionality expression at restaurants in Beijing area. 12 restaurants were selected and visited for the investigation research. The results were as follows. First, traditional reproduction was found mainly manifested through the reproduction of traditional ornaments, in particular, the facade and interior element ornaments. Second, Traditional transformation was mainly manifested in replacement material while changing the shape slightly, or to stretch or shorten prototype shape and other negative deformation methods which did not largely out of the scope of traditional reproduction. Third, Traditional reinterpretation was expressed by abstract, symbol or metaphor on designs, usually people can not directly recognize the traditional archetype. When compare with traditional reproduction or traditional transformation, traditional reinterpretation was relatively fewer, however, in this study the traditional reinterpretation and traditional transformation have same numerical result. Reinterpretation as a positive performance method of traditional modernized, it was encouraging the phenomenon, especially in the ceiling design. Chinese traditional cloud patterns have been three-dimensional and diversification of use. And in the wall design, traditional elements have been extremely simplistic or adopted a wide variety of traditional elements, it may be preferred in diversity. In addition, furniture was tinge traditional elements in modern form, lighting was added symbolize color or picture on the traditional lighting which shape was simplified to emphasize space's traditional. But the facade, sign board, floor, and window element seems the range of variation was not wild, promote more use the positive traditional reinterpretation method.

The Feasibility Study of a Light Rail Transit Development (경량전철 개발에 따른 경제적 파급효과 분석 연구)

  • Nam, Doo-Hee;Lim, Kwan-Su;Lee, Jin-Sun
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.1
    • /
    • pp.119-124
    • /
    • 2010
  • Light rail is an electric railway system, characterized by its ability to operate single or multiple car consists (trains) along exclusive rights-of-way at ground level, on aerial structures, in subways or in streets, able to board and discharge passengers at station platforms or at street, track, or car-floor level and normally powered by overhead electrical wires. Depending upon the specific system, the light rail lends some major advantages to urban settings. The evaluation of light rail technology as a potential component of regional transit systems has been the subject of extensive studies throughout the country in the past decade. For the study, feasibility was defined as "the ability of an LRT system to achieve certain level of transportation market in comparison with other transportation alternatives." This paper describes the feasibility study to evaluate a proposed light rail development project. The minimum are those LRT systems that would met to make a project feasible for further evaluation.

Mobile Guidance System for Evacuation based on Wi-Fi System and Node Architecture

  • Raju, Timalsina;Kim, Woo Sung
    • Journal of Information Technology Applications and Management
    • /
    • v.26 no.5
    • /
    • pp.41-56
    • /
    • 2019
  • Recently great loss of life and property is occurring because of fire, natural disaster, earth quake, tsunami and so on. People spend 80~90% of their time indoor environment like office, supermarket, campus. Therefore Indoor navigation and guidelines system became so essential for most of all. Incase of emergency we must be careful earlier, in such a cases 5G kind of new technology may also cannot work. So immediate action and quick routing notification for guidelines and protection is the most. Considering this issue We proposed indoor evacuating guidance system based on microcontroller Wi-Fi board for Indoor APP using mobile. Focusing various kind of technology like, ok google, voice search APP we purposed node architecture based system. When we listen fire alarm while living inside the room. Then to be safe we connect with server and start Arduino UNO+IoT ESP8266 Wi-Fi shield version1-IoT module to store data in MySQL DB server. We make application to escape out from the building up-to the three exits giving information from source point to destination. Our program can send information to the users emergency location and situations. For this when the user get sound or vibration in their mobile device it indicate fire out near by. At that time we update message from Arduino to DB server for the fixed current position inside the building which give routing signal for that fire out location by changing values from 0 to 1. We have user in point 10 where user is near by. Later we detect Wi-Fi signal form Nodemcu as room of each floor and try to connect with user. Main purpose of this paper is to save life of people in short time and find out the shortest path up to nearest exits in the time of emergencies and rescue them.

A Performance Analysis of Active Mount with Moving-Coil type Electromagnetic Actuator Installed on the Elastic Foundation (탄성지지된 가동코일형 능동마운트의 성능 분석)

  • Jung, Woo-Jin;Bae, Soo-Ryong;Jeon, Jae-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.227-231
    • /
    • 2014
  • Underwater radiated noise is one of the vital factors in underwater weapon systems like submarine. A passive elastic mount is an effective reduction method for the vibration from a ship-board machinery transmitted to the hull which is radiated as noise outside the hull. A passive elastic mount shows the limitation on the vibration reduction and needs multi stage mounting system including double stage one to meet the required underwater radiated noise criteria. It is necessary for the multi stage mounting system to consider the large displacement in the underwater shock explosion. So it is difficult to apply the multi stage mounting system in submarine because of space limitation. Also recent navy sonar system are trying to have the capability to detect the ship-borne acoustic signals in the low frequency range. An alternative to the passive mount is an active mount with moving-coil type electromagnetic actuator based on a conventional rubber mount in the low frequency range. In the previous paper, 4 active mounts with moving-coil type electromagnetic actuator based on the rubber mount were installed on the hard floor of the facility, which means no consideration on the elastic foundation effect for the control of the active mounts was taken into account. In this study, an experimental performance analysis on the active mount was carried out using 4 active mounts installed on the cylindrical structure to investigate the elastic foundation effect.

  • PDF

Risk Management and Telecommunications Research for customers of the accident location (사고선박의 고객위치파악용 위험관리 통신연구)

  • Kwak, Eun-young;Park, Dea-woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.331-335
    • /
    • 2016
  • When a boating accident, such as a January number three, the customer's risk management issues emerged. Ships and accident risk in confined spaces such as risk management to locate the customer and dangers of probation is available. In this paper, aboard after consent to obtain information for customers to wrist to customers, webbing or portable device embedded in devices and Wireless sensor information Input was attached, disposable consumer information. Customer on board the ship setting for location analysis and positioning according to information communication protocol, ships, each customer's real-time location information on the screen, 3 the foundation of d customers on the floor Can be designed to inform. Threshold designed to reduce the error of the information to analyze the position in current position and errors. Also, to system attacks would control the situation of accident and emergency jaenanguk server with real-time information transmission of information outside the emergency during a disaster, search and Disaster relief to be possible.

  • PDF

Habitability evaluation considering various input parameters for main control benchboard fire in the main control room

  • Byeongjun Kim ;Jaiho Lee ;Seyoung Kim;Weon Gyu Shin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4195-4208
    • /
    • 2022
  • In this study, operator habitability was numerically evaluated in the event of a fire at the main control bench board (MCB) in a reference main control room (MCR). It was investigated if evacuation variables including hot gas layer temperature (HGLT), heat flux (HF), and optical density (OD) at 1.8 m from the MCR floor exceed the reference evacuation criteria provided in NUREG/CR-6850. For a fire model validation, the simulation results of the reference MCR were compared with existing experimental results on the same reference MCR. In the simulation, various input parameters were applied to the MCB panel fire scenario: MCR height, peak heat release rate (HRR) of a panel, number of panels where fire propagation occurs, fire propagation time, door open/close conditions, and mechanical ventilation operation. A specialized-average HRR (SAHRR) concept was newly devised to comprehensively investigate how the various input parameters affect the operator's habitability. Peak values of the evacuation variables normalized by evacuation criteria of NUREG/CR-6850 were well-correlated as the power function of the SAHRR for the various input parameters. In addition, the evacuation time map was newly utilized to investigate how the evacuation time for different SAHRR was affected by changing the various input parameters. In the previous studies, it was found that the OD is the most dominant variable to determine the MCR evacuation time. In this study, however, the evacuation time map showed that the HF is the most dominant factor at the condition of without-mechanical ventilation for the MCR with a partially-open false ceiling, but the OD is the most dominant factor for all the other conditions. Therefore, the method using the SAHRR and the evacuation time map was very useful to effectively and comprehensively evaluate the operator habitability for the various input parameters in the event of MCB fires for the reference MCR.

The Microbiological Assessment and Identification of Food Utensils and Food Service Facilities in School (학교 급식설비 및 집기류의 미생물학적 위해요소 분석)

  • Hong, Seung-Hee
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.3
    • /
    • pp.189-194
    • /
    • 2014
  • This study was conducted to evaluate microorganism contamination of food utensils and service facilities in school and to prevent hazards by food poisoning occurrence. As a result, the highest number of microorganism growth plate ($12.3{\pm}2.6$) was detected in total bacteria test plate, and also observed $10.3{\pm}3.9$ growth plates in Staphylococcus aureus test plate and $9.5{\pm}3.9$ growth plates in E. coli and coliform bacteria test plate. But we could detect to the lowest number of growth plates ($1.5{\pm}1.0$) in Vibrio test plate. We also assessed that floors were appeared to the highest microorganism contamination rate in food utensils and service facilities. Therefore, $4.5{\pm}0.6$ growth plates was detected in pre-operation floor and $4.3{\pm}1.0$ growth plates in floor. And high level of microorganism contamination also observed in tables as $3.3{\pm}1.0$ growth plates in cooking table and $3.0{\pm}0.0$ growth plates in dining table. The level of microorganism contamination of food utensils such as kitchen knife, cutting board, and food tray were lower than that in food service facilities. We analysed microorganism contamination according to purpose of use in kitchen knifes and cutting boards. The microorganism contamination rate in fish kitchen knife ($2.0{\pm}0.8$) and fish cutting board ($1.3{\pm}1.5$) were slightly higher than that of others purpose of use. As a result of microorganism identification, various strains of microorganism were contaminated in food service facilities and some strains could detected more than two times. Especially, Staphylococcus aureus was repeatedly identified in cooking table, trench, and kitchen knife. Bacillus cereus was identified in kitchen knife, and then Pseudomonas fluorescens and Pseudomonas aeruginosa were also detected in food utensils and service facilities as known to food spoilage microorganisms. Klebsiella pneumoniae was detected four times repeat, which widely distribute natural environment as normal bacterial flora but sometimes cause acute pneumonia. These results suggest that food utensils and service facilities are contaminated with not only major food poisoning microorganisms such as Staphylococcus aureus, but also food spoilage microorganisms. Taken together, strict personal hygiene control and efficient food service facilities management will be needed to enhance food safety in school feeding and to improve student health.