• 제목/요약/키워드: Floor Type

검색결과 937건 처리시간 0.028초

NDVI RESPONSES TO THE FOREST CANOPY AND FLOOR IN EASTERN SIBERIA

  • Suzuki, Rikie;Kobayashi, Hideki;Delbart, Nicolas;Hiyama, Tetsuya;Asanuma, Jun
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.325-328
    • /
    • 2007
  • We discuss the Normalized Difference Vegetation Index (NDVI) of the forest canopy and floor separately based on airborne spectral reflectance measurements and simultaneous airborne land surface images acquired around Yakutsk, Siberia in 2000. The aerial land surface images were visually classified into four forest types: no-green canopy and snow floor (Type-1), green canopy and snow floor (Type-2), no-green canopy and no-snow floor (Type-3), and green canopy and no-snow floor (Type-4). The mean NDVI was calculated for these four types. Although Type-2 had green canopy, the NDVI was rather small (0.17) because of high reflection from the snow cover on the floor. Type-3, which had no green canopy, indicated considerably large NDVI (0.45) due to the greenness of the floor. Type-4 had the largest NDVI (0.75) because of the greenness of both the canopy and floor. These results reveal that the NDVI depends considerably on forest floor greenness and snow cover in addition to canopy greenness.

  • PDF

벽식구조 공동주택의 바닥충격음 개선에 대한 연구 (A Study on the Improvement of the Floor Impact Sound Insulation Performance in Wall Slab Type Apartment)

  • 김선우
    • KIEAE Journal
    • /
    • 제12권1호
    • /
    • pp.73-81
    • /
    • 2012
  • Floor impact sound has been most annoying for years among the noises which are produced in apartment. This study aims to analyze the improvement of floor impact sound by comparing the results of the test which was carried out for the wall slab type apartment and moment frame apartment, and also for the effect of advanced vibration isolation layer. Moment frame structure that main structure consists of column and slab has shown better performance for the heavyweight impact sound comparing with wall slab type structure which is general type in Korea. Stiffness of floor system was raised by reinforcing the stiffness of vibration isolation layer, and it was analyzed how much the floor impact sound performance was improved. The result showed that the reinforced floor had better performance than the existing floor system that uses lightweight porous concrete as vibration isolation material. In addition, a system used wire mesh in mortar showed improvement of floor impact sound than a system without wire mesh, and better performance for the frequency bands lower than 160 Hz which causes floor impact problem in wall slab type apartment.

지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구 (A Study on Comparison of Capacity between Wet.Dry Floor Heating Systems Using Geothermal Heat Pump)

  • 이병두;이세진;이대우;오성해;남우동
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.567-570
    • /
    • 2009
  • The present study conducted comparative evaluation of wet dry floor heating systems using geothermal heat pump. Circulation hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler was used. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.89^{\circ}C$ for wet type and $32.66^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. In the results, for floor heating system using low temperature circulation water, wet type was not enough to meet stable and comfortable radiant floor heating due to low floor temperature and access time to indoor set temperature. While dry type was practicable for stable floor heating due to fast rise of indoor set temperature and comfortable floor temperature.

  • PDF

지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구 (Comparative Study on Performance of Wet-type and Dry-type Floor Heating Systems Using Geothermal Heat Pump)

  • 이병두;이세진;이대우;오성해;남우동
    • 신재생에너지
    • /
    • 제5권4호
    • /
    • pp.60-65
    • /
    • 2009
  • The present study was conducted for a comparative evaluation of wet and dry floor heating systems using geothermal heat pump. We circulated hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.9^{\circ}C$ for wet type and $32.7^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. As a result, in case of floor heating system using low temperature circulation water, dry type was more practicable for stable floor heating than wet type in terms of floor temperature and access time to indoor set temperature.

  • PDF

The Relationship Between Cage Floor Preferences and Performance in Broiler Chickens

  • Zulkifli, I.;Khatijah, A. Siti
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제11권3호
    • /
    • pp.234-238
    • /
    • 1998
  • Two experiments were conducted with broiler chickens to determine cage floor preferences, the strength of preference for a particular floor type and to evaluate the effect of rearing broilers on the preferred cage floor on productivity. In experiment 1, chicks when offered free access to either wire (WF) or plastic (PF) mesh flooring, preferred the former. However, when the perferred floor type (WF) was illuminated at 800 lux, birds spent longer time on PF. Also provision of incandescent lamps at PF resulted in broilers spending significantly longer period on WF. In experiment 2, while floor type had no effect on growth of female chicks throughout the duration of study, male chicks grown on PF were heavier than their WF counterparts on Days 21, 28, 35 and 42. Neither livability, nor incidence of breast blisters and leg deformities was affected by floor type.

거실평면형태에 따른 공동주택 바닥충격음 차음특성 변화에 관한 실험적 연구 (An Experimental Study on the Floor Impact Sound Insulation of Apartment depending on the Plane Shape of Living-Room)

  • 박현구;박찬웅;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.844-847
    • /
    • 2008
  • As customer's demands are varying, the type of floor plan of apartment is changed into expanded type with balcony unified to living room from general type with balcony separated from living room and so is changing the layout of L(living room), D(dining room) and K(kitchen). This study aims to examine how the type of floor plan of living room affects the floor impact sound insulation performance and to propose fundamental idea to floor plan layout of apartment in terms of floor impact sound reduction.

  • PDF

EVA 완충재의 형상변환을 통한 복합구조의 바닥충격음 변이 조사 (Investigation of the level difference of floor impact noises through the shape variation of EVA resilient materials with composite floor structure)

  • 이야긴;이승민;한찬훈
    • 한국음향학회지
    • /
    • 제43권1호
    • /
    • pp.60-71
    • /
    • 2024
  • 본 연구는 일반적인 평평한 에틸렌 비닐 아세테이트(Ethylen Vinyl Acetate, EVA) 완충재의 형상을 변화시켜 다양한 차음소재와 조합하여 복합구조의 바닥충격음 변화를 조사하는 데에 목적이 있다. 바닥충격음 저감에 효과적인 완충재를 선정하기 위해 Flat, Deck, Cavity type의 EVA, EPS, PET 흡음재, PP판넬, 고무발판 등 다양한 완충재를 조합하여 뱅머신을 이용한 1차 실험을 진행하였다. 1차 실험 데이터에 대해 통계분석한 결과 완충재 두께가 40 mm에 가까울수록 바닥충격음 저감효과가 증가하였으며 PET 흡음재, PP시트, 고무발판 등을 조합한 복합완충재에서 바닥충격음 효과가 증가하는 것을 알 수 있었다. 이에따라 2차 실험에서 모든 복합완충재의 두께는 40 mm로 통일하였으며, 1차 실험에 사용된 Flat, Deck, Cavity type 및 EVA를 발판형태로 가공한 Mount type 등 4가지 형태의 복합완충재를 설계하였다. 또한, Mount type을 제외한 3가지 기본 형태에서 각각 PET 흡음재(7 mm)를 추가했을 시 바닥충격음 변화를 살펴보았으며, Mount type의 경우 EVA발판 개수에 따른 바닥충격음 변화에 대해 고무공 충격원을 이용한 2차 실험을 진행하였다. 모든 실험은 공인인증시험기관의 목업실험실에서 진행하였다. 실험 결과, 기본형태의 Flat, Deck, Cavity type에서 PET를 추가할 경우 통계적으로 경량 5 dB ~ 9 dB, 중량 1 dB ~ 5 dB의 저감효과가 나타난 것을 알 수 있었다. 특히, Mount type의 경우 발판 수가 36개 이상일 때 경량 및 중량충격음에서 우수한 것으로 나타났다. 또한, 4가지 기본형태에 따라 동탄성계수가 높아질수록 바닥충격음의 저감이 증가하는 것으로 나타났다.

캐나다 단독주택 설계의 평면구성 특성 (Characteristics of the Floor Plan of Single Detached Houses in Canada)

  • 박선희
    • 한국주거학회논문집
    • /
    • 제14권6호
    • /
    • pp.205-214
    • /
    • 2003
  • The purpose of this study is to investigate the characteristics of the floor plan of single detached houses in Canada. A quantitative & qualitative analysis method of th 260 house plan was used in this study. The followings were found out from this analysis : 1) There were the differences of the lay-out and the number of public spaces between a small type and a big type. 2) There were the differences of the equipment and the number of bathroom between a small type and a big type. 3) The most work center type of kitchen was 'ㄴ+ㅁ' type(33%). 4) The most type of floor plan was that one with attached garage(87%) and center entry(99%). 5) Almost floor plans having 3 or 4 bed rooms even though medium II and large size plans which is to show that the basic needs of family life rely on the omnifarious public spaces.

원전 주제어실 3차원 층면진시스템의 진동대 실험 연구 (Shaking Table Test Study on 3-Dimensional Floor Isolation of Main Control Room of Nuclear Power Plant)

  • 이경진;함경원;서용표;윤현도
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.409-416
    • /
    • 2006
  • The seismic characteristics with 3-Dimensional Floor Isolation System have been studied using a shaking table system. In this study, we made two kind of floor system (Type I, Type II) and several seismic tests with and without isolation system were conducted to evaluate 3-Dimensional Floor Isolation Effectiveness. Both type have showed large reduction effectiveness in acceleration, response spectra but Type II have showed lower acceleration and lower first mode in response spectra, compared to type I. On the basis of test results and consideration of application, it is found that type II is more suitable for floor model of main control room of Nuclear Power Plant.

  • PDF

탑상형 아파트의 층별 전기와 가스 부하량 비교평가 (Comparative Evaluation of Electric Power and LNG Load according to Floor level of Tower-Type Apartments)

  • 김준현;최진호;엄정섭
    • 환경영향평가
    • /
    • 제20권4호
    • /
    • pp.465-475
    • /
    • 2011
  • It is known that energy consumption in bottom floor of typical Korean-style apartment is the highest. Previous studies for energy consumption in accordance with floor level appear to be very limited due to the dependence on single energy variable such as electric power or LNG separately, based on past flat type of apartment. Acknowledging these constraints, an empirical study for a tower type emerged recently as new style of apartment in South Korea was conducted to demonstrate how a comprehensive evaluation for both electric power and LNG consumption can be used to assist in monitoring the total energy consumption in terms of floor specific settings. It was possible to identify that energy consumption in bottom floor is lesser than that of top floor, to the contrary, fact known from previous study. Also electric power consumption in top floor was identified as 15% higher than that of floor in the least. It is anticipated that this integrated utilization of electric power and LNG data would present more scientific and objective evidence for the energy load among floor level of tower type apartment by overcoming serious constraints suffered from the past single variable investigation. Ultimately, the result in this paper could be used as a valuable reference to providing priority for energy saving activities in top floor such as cool roof or green roof.