• Title/Summary/Keyword: Floor System

Search Result 1,855, Processing Time 0.046 seconds

A study on development of dry ondol access floor system for sustainable apartment (지속가능형 공동주택 구현을 위한 건식온돌 이중바닥 시스템 개발)

  • Oh, Jin-Kyun;Sohn, Jang-Ryul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.689-689
    • /
    • 2010
  • Since the apartment was built by Korea National Housing Cooperation in 1961, the amount of its supply has been increased greatly, especially from the late 70's. Recently there are many ongoing studies regarding sustainable construction apartment in Korea, one of the research is developing sustainable apartment that has longer life cycle. Also according as life's quality of residents is upgrading, complain for impact noise and plumbing system noise from upstair or downstair are increasing more and more. To solve this complains, government established impact noise standard as lightweight impact noise of 58dB, heavyweight impact noise of 50dB and presented standard floor system or recognition floor system to satisfy this impact noise standard. So in this study, the aim is to develop dry ondol access floor system for sustainable apartment which have pleasant and quiet life environment.

  • PDF

A Study on the Development of Rolled Dry Floor Heating System for Improving Workability (현장 시공성 개선을 위한 롤타입 건식바닥난방시스템 개발)

  • Lee, Gyu-Dong;Kim, Jun-Ho;Jeong, Chang-Ho;Kim, Dong-Woo;Ogawa, Keiichiro
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.177-180
    • /
    • 2012
  • Korea residential housing generally use wet floor heating system 'Ondol' which consist of insulation cushioning, lightweight foamed concrete, hot water pipe and mortar on top of reinforced concrete slab. Wet floor heating system's installation process is too complicate and difficult to supervise field for continuing assurance quality. Also, this method has a huge impact on the progress of construction because it take a long time to cure finishing mortar and lightweight foamed concrete. Therefore, it is considered a disturbance factor of reduction of construction duration for enhancing competitiveness. In this study, we conducted an experiment about the radiant heat performance and temperature difference on upper panel of rolled dry floor heating systems which is jointly developed by Kolon global and Sumisho Metalex for remodeling housing, studio apartment and the urban-life housing.

  • PDF

The Comparison of Space Origination between Korean-Chinese and Chinese Multi-family Housing in China (중국 연변 조선족과 한족피 집합주택 평면구성 비교 연구 - 연길시를 중심으로 -)

  • Kim Jong Young
    • Journal of the Korean housing association
    • /
    • v.15 no.4
    • /
    • pp.55-63
    • /
    • 2004
  • The aims of this research are to find the difference of space origination between Korean-Chinese and Chinese multi-family housing unit plan and to find the main reason to make this difference. To do this research, twenty three different kinds of floor plans were surveyed and examined. The results are as follows; 1. The Chinese-Korean floor plan and Chinese floor plan in Ondol heating system are totally different, although in radiator and floor panel heating system are similar. The inner space origination between two races are different. That is to say, Chinese-Korean likes open space origination and Chinese likes closed space origination. 2. The main reasons to make differences seem to be living style, heating system, constructional method and the trade with South Korea. In the future time, the usage of floor panel heating system will be increased and various kinds of floor plan should be introduced.

Application Study of the Predictive Pulse Control for Floor Heating System (바닥난방을 위한 부하 예측식 펄스제어 방식의 적용성 연구)

  • Cho, Sung-Hwan;Kim, Seong-Su;Kim, Yong-Bong;Na, Hee-Hyeong
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.167-175
    • /
    • 2007
  • A predictive pulse control strategy as a means of improving the energy efficiency of radiant floor heating systems is explored. Experiments at the apartment with floor heating system are conducted to assess and compare the energy performance of the predictive pulse control strategy with an existing conventional control strategy. The Results showed that new suggested PPCM( Predictive Pulse Control Method) was available to decrease the gap of $1{\sim}1.5^{\circ}C$ between maximum and minimum indoor temperature of each rooms. Therefore PPCM method was favor to radiant floor heating system which have a delay time of 10-20 minutes for heat transfer by floor layers.

  • PDF

Evaluation of Natural Ventilation Performance using the Multi-Functional Floor Heating System (다기능온돌시스템을 이용한 자연환기성능 평가)

  • Cho, Dong-Woo;Yu, Ki-Hyung;Yu, Jung-Yeon;Jung, Hae-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.105-112
    • /
    • 2007
  • Recently developed raised floor heating system is not only capable of basic function to reduce noise between floors, but also is a multi-functional floor heating system enabling natural ventilation. The procedure of this system for natural ventilation is to import outdoor air through bottom space of the floor heating system, circulate indoor space and discharge it out of ceiling. In winter, powerless natural ventilation is possible with buoyancy effect caused by temperature difference between outdoor and indoor. And it also allows saving of energy by importing pre-heated air in bottom space of the floor heating system. To evaluate ventilation performance of this system, on-site measurement was conducted in 2 test laboratories, and the nominal air change rate was satisfied as 0.4$\sim$0.8 h-1 under the condition of outdoor temperature $5^{\circ}C{\sim}-5^{\circ}C$, which was evaluated as highly possible to be applied as a natural ventilation system in multi-family houses.

  • PDF

A Study on the Improvement of Average Floor Height Ordinance through Analyzing Landscape Impacts of Average Floor Height System Applied to Apartment Buildings in Residential Areas of Seoul (공동주택 평균층수 적용에 따른 경관영향 분석 및 제도운용 개선방안 연구)

  • Mok, Jeong-Hun;Kim, Sung-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.3
    • /
    • pp.62-70
    • /
    • 2007
  • The purpose of this research is to suggest an improved method of how to apply and operate an average floor height system to rebuilt or redeveloped apartment buildings in general residential areas of Seoul. This research suggested two research findings by a computer simulation study for analyzing the difference between the average floor height of apartment buildings in experimental sites and the average of floors of buildings near experimental sites. The first finding is that an average floor height system should be applied to apartment buildings with a limitation of maximum height at sites larger than $12,000m^2$ in order to control the difference of the maximum height of buildings between apartment sites and their surroundings. The second finding is that the average floor height system should be operated by an appropriate average floor height ratio at sites greater than $50,000m^2$ in order to harmonize rebuilt or redeveloped apartment buildings with their surroundings.

Estimation of the thermal performance on the double slab floor with supplying air (급기가 되는 이중바닥 구조체의 열 성능 평가)

  • Cha, Kwang-Seok;Park, Myung-Sig;Lee, Dae-Woo;Nam, Woo-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.866-871
    • /
    • 2006
  • Recently according to the fashion of well-being, the case study of under floor heating system type for residential space is increasing. Specially double slab floor system can make several roles as reducing the acoustic noises and also supplying fresh air through the gap. So in present study floor heating performance was examined with various location of the space in the case of floor supply air and ceiling supply air. In both cases return air went out through ceiling opening. As one of the result is that when using the heat pipe type floor heating system the temperature difference between supply and return water was $15.2^{\circ}C$, but in case of commercial type floor heating system the temperature difference was $5.3^{\circ}C$ when the supply water temperature was $50^{\circ}C$.

  • PDF

Prediction of Concrete Slab Acceleration and Floor Impact Noise Using Frequency Response Function (주파수 응답함수를 이용한 콘크리트 슬래브 가속도 및 바닥충격소음 예측)

  • Mun, Dae-Ho;Park, Hong-Gun;Hwang, Jae-Seung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.6
    • /
    • pp.483-492
    • /
    • 2014
  • Uncomfortable feelings of occupants by indoor floor impact noise in a residential building are not accurately represented by the floor impact noise from a standard impact source. It is due to the characteristics of standard impact sources, which are different from the impact forces produced by occupants. It varies significantly by impact source, and it is not easy to be replicated for testing. As a result, the indoor floor impact noise under different acoustic conditions cannot be directly compared. Using frequency response function(FRF), which represents the input-output relationships of a dynamic system, it is possible to examine the characteristics of the system. Especially, FRF can predict the response of a linear dynamic system subjected to various excitation. To determine the relationship between impact force and the corresponding response of dynamic system in residential building, the acceleration response of a concrete slab and the floor impact noise in the living room, produced by bang-machine and rubber-ball excitation, were measured. The test results are compared to the estimates based on FRF and impact force spectrum.

A Study on the Dynamic Characteristics of Composite Deck Plate According to the Modification of Boundary Conditions (경계조건의 조절에 따른 합성 데크플레이트 슬래브의 거동특성에 관한 연구)

  • 김우영;정은호;엄철환;김희철
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.371-376
    • /
    • 1998
  • As the requirement of high-rise buildings in big cities increases, steel structural system becomes more popular in spite of the relatively higher material cost compared to that of the concrete structural system. Most of the steel structure adopts metal deck floor system because of the easiness in construction. However, the metal deck floor system has a weakness on vibration which became very important factor in office buildings, hotels and residential buildings as the more sensitive machines being used. Therefore, most, of the building codes in many countries restrict the natural frequency of the each floor should be higher than or equal to 15 Hz. Floor vibration of the KEM deck composite floor system which has been , developed recently from the engineers and scientists in Korea was measured. Also, the simplified analytical derivation of natural frequency for each floor was studied according to the measured natural frequency for each different boundary condition of the floor. As the length of the slab gets bigger, the natural frequency of the slab becomes lower even though the structural designer still considers it as a one-way slab.

  • PDF

Vibration Analysis for the Living Room Slab of Apartment (아파트 거실 바닥판에 대한 진동해석)

  • Kim, Yong-Tae;Park, Kang-Geun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.3 s.21
    • /
    • pp.93-101
    • /
    • 2006
  • Recently the floor vibration of apartment is often beginning to make its appearance of the environmental dispute, the standard floor system of housing are suggested for the settlement of this issue by government. For the slab vibration analysis on the laminated floor system of apartment, it is required the effectively analytical method of the floor system considering laminated theory. In this paper, more effective modeling methods of laminated floor slab are proposed for the method of accurate rigidity evaluation. By using the advanced modeling method, the more accurate vibration response can be obtained and can accurately evaluate the rigidity of living room floor system of apartment with different laminated materials.

  • PDF